Loading...
HomeMy WebLinkAboutEngineer Calcuations and Detail ReportJOB NAME . NEIL ROSENBERG LOCATION:sitt, co 81652 30'x40'x12' DESCRIPTION: 102913PO NO.: 6t212021DATE: CALCULA DETAILS Salem Salem, P.E. Registered Professional Engineer 31893 O Dlæ /t'1/2'1/2'ANCHOR BOLT SETÏINGNOTE ATI BASE PLA1ES AT EI..EVATON1)IBC-18Z)Moke gint stnut 1494, of RtV tien bnace, No slotsat connection,3)Add stub pur^lins o.t tines 1& 34)Up-stope o.,r,r,5)N,4,CMlSSAAU'YER'cusT, 'SITE 'DESCR'SCALETP.E rSunwondNell R6anbetgìH R6.nb"rgstt,ü¡S.e El.vqtlonsMNEÍ129t3I'RAVI{ Bï-_w_CHECX BYr-ífu/a,DES ElG. '_Steet BuitdingsSHEEI III fF Jtne 02,2021 NEILROSENBERG NEIL ROSENBERG 2386 Odin Drive silt, co 81652 RE: 30'x40'x 12' Salem Salem, P.E. Registered Professional Engineer SUNWARI} STEEL BUILDINGS PO # 702913 Dear Final Owner, This is to certiff that the above referenced structure is being designed in accordance with the International Building Code 201 8 0 for the following loads in addition to the dead load of the structure. a) Risk Category: II - Normal b) Roof Live Load = 20 psf Tributary Reduction? [ Yes M No RoofSnow Load, Pf:40 psf (Ground Snow Load, Pg:57.14 psf with Ce: 1, Ct = l) Snow Importance : I c) Wind Speed , V, ultimate= 115 mph, Exposure C Wind Speed, V, asd:89 mph Component Cladding Pressure: 28.9 psf Component Cladding Suction: -3 1.3 psf Intemal Pressure Coeffl: 0.18/-0.1 8 d) SeismicData: Ss=0.311, Sl:0.08, Sds:0.322, Sdl:0.128 Site Class D, Seismic Importance : I Seismic Design Category: B Seismic Response Coeff., Cs:0.099 Response Modification Factor., R = 3.25 Longitudinal Bæe Shear (kips) : 1.75 Transverse Base Shear (kips): 1.84 Equivalent Lateral Force Analysis Procedure Seismic Force Resisting Systems: Steel Ordinary Moment Framo (OMF) Steel Ordinary Concentrically Braced Frame (OCBF) e) Crane: Capacity =N/A tonsnrn [u¡n CMAA - Class C unless noted f) Mezzanine Size = N/A ¡¡= psf DL= psf C) Building Enclosure Type: Enclosed Partially Enclosed Open h) Deflection Criteria: M ManufacturerStandard f, Other (Specifu): i) Collateral Load (psf: I Others (Specifu): j) Dead Load (psf) :2.2 n ir,loxoRatr- This certification is in accordance to the design loads you requested and specified in the purchase order agreement. The building is designed in accordance with AISC, ASD Fifteenth-Edition, AISI2016 Edition and MBMA Standard. Sunward Steel Buildings, Inc. makes no representations as to the adequacy ofthe design loads on the building components you have ordered. It is your responsibility to contact your city or county building officials to determine ifthe specified design loads you requested are adequate for your geographical area. If you are unfamiliar with the design loads required to obtain the necessary building pennits, please contact your building official immediately and veriff that the loadings you ordered are correct and in accordance with your building official's requirements for obtaining the necessary permits. Sunward Steel Buildings, Inc. limited wananty and engineering data are set forth in your SALES ORDE& LIMITED WARRANTY and MANUFACTURER'S AGREEMENT. This certifîcation covers parts manufactured by Sunward Steel Buildings, Inc. only and excludes such parts as doors, windows, masonry, foundation design and erection of the building. The building components not manufactured by Sunward Steel Buildings, Inc. are listed below: Material: N/A Manufacturer's Name: N/A Fabricating Location: \/A The undersigned is not the engineer ofrecord for the overall project. Sincerely, {p a\