Loading...
HomeMy WebLinkAboutConditions of PermitCOND ITIONS OF PE RMIT B LRE-0 5-22-7 538 MATTHEW & KIM GILLEN New 5/F Dwellíng with attached garage 2131 Elk Springs Dr., GWS Elk Springs, Los Amigos, Flg B, Ph 1, Lot 2 1 ) ALL WORK SHALL COMply WITH THE 2015 TNTERNATIONAL RESIDENTIAL CODE (l.R.C.) AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.) 2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED lN THE ATTACH ED "GARFI ELD COU NTY BU I LDING REOUI REM ENTS". NU M BER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTTtNc AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. 5) pRE FABRTCATED ROOF TRUSSES. HAVE ENGINEERING FOR INSPECTOR AT TIME OF FRAME INSPECTION. ó) opEN HOLE SOTLS REPORT rS REOUTRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. STRUCTURAL ENGINEER HAS DESIGNED FOUNDATION SYSTEM AT 2,OOO PSF SOIL BEARING. 7) A LOT TMPROVEMENT CERTIF|CATE, SEALED BY A COLORADO LICENSED SURVEYOR, lS REOUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE - INCLUDING ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WITH MINIMUM SETBACKS AND/OR BUILDING ENVELOPE REOUIREMENÏS. 8) ALL HtcH STRENGTH BOLT|Nc AND FTELD WELDING REOUIRES SPECIAL INSPECTOR. PROVIDE APPROVAL REPORT AT FRAMINC INSPECTION.