HomeMy WebLinkAboutOWTS Design129 Cerrus Larr,rE
CaReor.¡oRlE, CO a1 623
970.309.5259
CARLA.oSTBERG@GMAI L.CoM
r.tf.;t"l' I(' ('( t¡i¡.t(' t-"t'I s;( ;
June 4,2022 Project No. C1708
Maureen O'Brein
Up4walk@yahoo.com
Subsurface lnvestigation and Onsite Wastewater Treatment System Design
2-Bedroom Residence
24 CR 111
Garfield County, Colorado
Maureen,
CBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The 0.209 property is located outside of Carbondale, in an
area where OWTSs are necessary. The parcel is located on the northeast of the intersection of Hwy 133
and CR 111 (Prince Creek Road).
Legal Description: Section: 3 Township: I Range: 88 A TR lN LOTS 18, 19 (SEC 3), & LOT 1 (SEC f O).
A TRACT OF LAND LOCATED IN THE SE % OF SEC 3 AND THE NE % OF SECTION 10
CONTAINING .21 AC+I-, SAID TRACT BEING MORE PARTICULARLY DESCRIBED PER SPECIAL
WARRANTY DEED.
Parcel lD: 2463-034-00-049
SITE CONDITIONS
The parcelwas previously developed with a modufar home which has since been removed.
A new, 2-bedroom residence is proposed
The residence will be served potable water from the town of Carbondale. We believe the existing water
line is likely galvanized from the original development of the parcel. We recommend the water liñe be
replaced. This water line must be at least 25-feet from the soil treatment area (STA) or if it comes within
2S-feet of the STA, it must be encased (see W4.0/3 Encasement Detail).
A ditch runs along Hwy 133 to the west. No OWTS components may come within 5O-feet of the ditch.
Setbacks to the proposed STA include 2O-feet from the residence and 1O-feet from the property line.
This site is constrained and there may be slight encroachment on the setbacks to the house and
property lines. The area is relatively flat and will be located to the south of the residence.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
Page 2
SUBSURFACE
The subsurface was investigated on April 19,2A22 by digging one soil profile test pit excavation (Test Pit). A
visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation..l Only one Test Pit
was excavated due to limited area on the property.
The materials encountered in Test Pit #1 consisted of dark brown topsoil to 2.O-feet, underlain by medium
brown clay loam to 5.S-feet, underlain by reddish brown sandy loam and cobbles to a maximum depth
explored of 8.O-feet. No bedrock or groundwater was encountered.
A sample of the soils was taken from Test Pit #1 at 3-feet below grade. Soil structure grade was
moderate to weak. The soil formed a ball and a ribbon 1 to 2-inches in length before breaking. Soil
structure shape was blocky and consistence was friable to firm. Soil texture was both gritty and smooth.
This soil is classified as SoilType 3 to 34, Clay Loam.
Another sample of the soils was taken from Test Pit #l at 5.5-feet below grade. The structure grade was
moderate. The soilformed a ball and a ribbon less than 1-inch before breaking. Soil structure shape
was single-grain. Consistence was loose. Soil texture was gritty. This soil is classified as Sandy Loam
with rock content between 35-65%, Soil Type R-1.
We are proposing an over-excavated, unlined sand filter with a minimum 3-feet of Secondary Sand
installed at a depth of 5.5-feet. A long term acceptance rate (LTAR) of 0.8 gallons per square foot
will be used to design the OWTS.
Test Pit #1
I Carla Ostberg holds a Certificate of Attendance and Examination from the CPOWVisual and Tactile
Evaluation of Soils Training.
Page 3
Clay Loam to S.5-feet
Firm, blocky peds
Sieved sample Ribbon 1-2 inches in length
Page 4
Backfill
Sieved sample Ribbon less than 1-inch
DESIGN SPECIFICATIONS
Any existing OWTS components from the former residence on the propêrty must be properly abandoned.
Desion Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 2 Bedrooms = 300 GPD
LTAR = 0.8 GPD/SF
300 GPD / 0.8 GPD/SF = 375 SF
The OWTS design is based on 2-bedrooms. An average daily wastewater flow of 300 GPD will be used
For the purposes of this OWTS design, Benchmark Elevation has been established as 100' as the
Finished Floor elevation of the Main Level of the residence. CBO lnc. should be notified of any
discrepancies or problems with grade elevations of proposed components during installation of the
OWTS.
:
\
Sandy loam with cobbles at 5.5Jeet
Page 5
*Elevations are based upon standard OWTS installation practices. Component elevations may change during
installation due to site conditions. Minimum grade refers to piping between components.
The sewer line exiting the residence must have a double-sweep clean out and a minimum 2o/o grade to
the septic tank.
The system installation will include a 1O0O-gallon, two-compartment concrete Valley Precast septic tank
with an Orenco@ Biotube Pump Vault and an Orenco@ PF3005 pump in the second compartment of the
septic tank. The floats should be set to dose approximately 55 gallons each pump cycle, allowing
approximately 3 gallons of drain back after each pump cycle. A pump curve is enclosed. The control panel
for the pump must be located within line of sight of the septic tank. We recommend Valley Precast out of
Buena Vista be contracted for start-up of the pumping system.
Table
Effluentwill be pumped through a 1.5-inch diameter pump line from the pump chamber to an Orenco@
automatic distributing valve (ADV), model 6402. This pump line must have a minimum 1o/o grade for proper
drain back into the tank after each pump cycle. The ADV must be placed at a high point in the system in an
insulated riser with access from grade. Screened rock must be placed below the ADV to support the ADV
and to assure the clear pipes exiting the ADV remain visible for future inspection and maintenance.
Effluent will be pressure dosed through 1 .5-inch diameter distribution lines to a 13' x 29' bed. A minimum of
3{eet of sand filter material will be installed in the over-excavated footprint. The excavation must extend
to the soil horizon with sandy loam and cobbles. Sand filter material must be clean, coarse sand, all
passing a screen having four meshes to the inch. The sand must have an effective size between 0.15 and
0.60 mm. The uniformity coefficient must be 7.0 or less. Material meeting ASTM 33, for concrete sand, with
three percent or less fines passing 200 mesh sieve may be used. A gradation of the sand media must
be submitted to this office prior to obtaining the sand.
Laterals must be 1.5-inches in diameter with 5/32-inch diameter orifices facing down, spaced 2-feet on
center, installed on the GeoMatrM with the filter fabric over the laterals. Laterals should be placed 2-feet
from the edges of the bed with 3.0-feet between the middle laterals. Four 39" wide GeoMatrM must be
placed on the 13-foot wide bed. All material associated with the GeoMatrM installation must be proprietary
products associated with the GeoMatrM, including orifice shields and geotextile fabric. Manufacturer
instructions must be followed regarding installation of the GeoMatrM.
OWTS Gomponent Minimum Elevation
Primary Tank lnlet lnvert Approximate horizontal distance B' / min. 2o/o lall I
min.2" fall
Automatic Distributing Valve Approximate horizontal distance 31' / min. 1o/o rise I
min.3.875" rise
lnfiltrative Surface Approximate horizontal distance 10' / min. 1% fall I
min. 1 .25" fail
Dose Range Max = 78 gal. (300 GPD x25o/o +
3 qal drain back)
Min. 31 gal. (7 gal x 4) + 3 gal
drain back
Dose Setting 55 gallons/dose 3 gallons drain back (31' I 1.5"
diameter pump line)
Float Separation 1000 gallon 2-compartment
Valley Precast concrete septic
tank
8" on/off float separation
Pump Criteria 20.3 gallons per minute (GPM)15.4 feet total dynamic head
(TDH)
Page 6
Each 1.5-inch diameter lateral must end in a sweeping ell facing up with a ball valve for flushing. Valves
should be placed in a 10-inch sprinkler box for access. Laterals must be covered by the gray soil
separation fabric and at least 1-foot of topsoil or other suitable soil able to support vegetative growth. There
shall be no coþble-sized (<2.5') or greater rock in final cover over the GeoMatrM, lnspection ports must be
placed at each corner of each bed. Ports may be cut to grade and covered with a valve box for access.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO lnc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
Construction must be according to Garfield County On-Site Wastewater Treatment System Regulations, the
OIVTS Permit provided by Garfield County Building Department, and this design.
INSTALLATION CONTRACTOR
CBO lnc. cxpccts that tho installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS
CBO lnc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO lnc. should be notified 48 hours
in advance to observe the installation.
GOMPONENT MANUFACTURER MODEL NO COMMENTS
Septic Tank Valley Precast Item # 1000T-2CP-HH 1000-gallon,2-
;ompartment concrete
septic tank with high
head pump
Pump Orenco@ PF300511%HP
'120 Volt
Brotube ProPak Pump
Packaqe
Orenco(Ð BPP30DD Vault, Filter, Control Panel
Ídemand dose)
Tank Risers and Lids Orenco@ ljouþle-walled PVÇ Rtsers and
Lids (24" diameter)
ADV Orencoß)v64024 1.5" lnlet and Outlets
AIJV l-{tser and Ltd OrencoG)Double-walled PVC Risers
and Lids (30" diameter)
3eoMat rM GeoMatrix Systems,
LLC
,116, GeoMalru (39,, sheets)
52 orifice shields
Flushing Assembly orenco(Ð 1.5" dtameter
Page 7
ln an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the propefi. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high-
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
Page I
LIMITS:
The design is based on information submitted. lf soil conditions encountered are different from conditions
described in report, CBO lnc. should be notified. All O\ /TS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO lnc.Reviewed By
(ß'\tæ }stú'rxg
Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE
t I
I6 2-2022
T
tÞas8e3
Pump Selection for a Pressurized System - Single Family Residence Project
24 CR 111
Parameters
Discharge Assembly Size
Transport Length Before Valve
Transport Pipe Class
Transport Line Size
Distr¡buting Valve Model
Transport Length After Valve
Transport Pipe Class
Transport PÌpe Size
Max Elevation Lift
Man¡fold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Lateral Pipe Class
Lateral Pipe Size
Orifice Size
Orifice Spac¡ng
Residual Head
Flow Meter
'Add-on' Friction Losses
inches 300
250
inches 200
feet
Calculations
100
Minimum Flow Rate per Or¡fice
Number of Orifices per zone
Total Flow Rate per Zone
Number of Laterals per zone
% Flow Differential lsvLast Or¡fice
Transport Veloc¡ty Before Valve
Transport Velocity After Valve
Frictional Head Losses
t.¿c
40
1.50
6402
10
40
1.50
2
3
40
1.50
4
28
40
1.50
5132
5
None
U
feet
inches
feet
leet
feet
inches
inches
inches
feet
feet
inches
feet
d,ol¡.
to
da!oT
.9
EoË
o
1!
Ê
150
50
PumpData
5 l0 15 20 25
Net Discharge (Spm)
30 35 40
0.68
30
20.3
2
0.7
3.2
3.2
gpm
gpm
o/o
fps
fps
Loss through Discharge
Loss in Transport Before Valve
Loss through Valve
Loss in Transport after Valve
Loss in Manifold
Loss rn Laterals
Loss through Flowmeter
'Add-on' Frict¡on Losses
Pipe Volumes
2.9
0.8
4.3
0.3
0.0
0.'1
0.0
0.0
feet
feet
feet
feet
feet
feet
feet
feet
0
0
d
Vol of Transport Line Before Valve 3.3
Vol of Transport Line After Valve 1.1
Vol of Manifold 0.3
Vol of Laterals perZone 5.9
Total Vol Before Valve 3.3
Total Vol After Valve 7 .3
lquirements
gals
gals
gals
gals
gals
gals
PF3005 H¡gh Head Effluent Pump
30 GPM, 1/2HP
1151230V 1Ø 60H2,200Y 3Ø 60Hz
PF3007 High Head Effluent Pump
30 GPM, 3/4HP
230V 1Ø 60H2, 200/460V 3Ø 60Hz
PF3010 High Head Effluent Pump
30 GPM, 1HP
230V 1Ø 60H2, 200/460V 3Ø 60Hz
PF3015 High Head Effluent Pump
30 GPM, 1-1l2HP
230V 1Ø 60H2,20012301460V 3ø 60Hz
gpm
feet
çYSfEMSM
System Curve: -
Pump Curve: *
Pump Qptmal Hange:_ouperalrng Pornl:
o
Design Point:
20.3
15.4
NÅr-------tSCALE: r = 5ü=t'RESIDENCEISEPTICTANKLINEtCOUNTY ROAD I11)THE LOCATION OF PROPOSED IMPROVEMENTS SHOWN ARENOT THE RESULI OF A PROPERry SURVEY. THE LOCATIONSARE APPROXIMATE. IT IS TI.IE HOMEO/VNERS' DUTY TOENSURÉ ALL CONSTRUCTION AND IMPROVEMENÏ LOCATIONSARE ACCURATE. PROPERTY LINES AND SETBACK DISTANCESSHOULD BE CONFIRMEO PRIOR TO EXCAVATION. SCALEDFOR PR¡NTING ON 1 1" X 17" PAPER.DRAWINGS MUST BE USED INCONJUNCTION WITH DESIGNLETTER DATED O610412022ASITE PLANSTA-\\LINEv{2.0w1.0Sheel 1 F 4Eate: æ10412022Designed by: CBOReviewed by: RBtrrawn by: DDO'Brien Residence2¡t CR 1 11Garfield County, CoþradoProjectNumber: C1708CBO lrìc.129 Cair¡s LæeCarbondâle, Colorado 8'l 623Phonê 970.3o9.5259carla.ostberg@gmail.æmM
CBO lnc.1 29 Cains LaneCarbondale. Colorado 81623Phone 970.309.5259carla.ostberg@gmail.com30'DIAI\¡ETER PVCSTA TO DITCH50'74',STA TO WELL1 00'N/ASTA TO HOUSE20'19'*SEPTIC TANK TO DITCH50'r00'SEPTIC TANK TO WELL50'N/AHOUSE TO SEPTIC TANK5',8'OW]'S COMPONENÎS ANDPHYSICAL FEATURESMINIMUM REOUIREDSETBACKAPPROXIIVATE PROPOSEDSETBACKRISERDESIGN2-BEDROOM RESIDENCE(75 GPD x 2 PERSONS/BEDROOM x 2 BEDROOI\¡S)WASTEWATER FLOW = 300 GPDTANK:USE lOOO-GALLON, TWO-COMPARTMENT CONCRËTE SEPTIC TANK WITHORENCO PUMPING SYSTEM IN SÊCOND COI\,IPARTMENT.DISTRIBUTINGVALVE ASSE¡,¡lBLYFROMPUMPING1.5' DtA SCH-40PVC INLET ANDOUTLETSSOIL TREATIVENT AREA (S-TA):LONG TERI\¡ ACCEPTANCE RATE (LTAR) = 0.8 GAL/ SFCALCULAïED STA = Q/LTAR = 300 / 0.8 = 375 SFOVER-EXCAVATED UNLINED SAND FILTER WITH MIN. 3' SAND FILTERMATERIAL (OVER-EXCAVATION IVUST EXTEND TO THE COBBLE DEPTH)13'X 29'BED WÏH GEOMAT FOR DISTRIBUTION*DUE TO SITE CONSIRAINS. THERE MAY BE SLIGHT ENCROACHMENTS fOSETBACKS TO THE HOUSE AND SOUTHERN PROPERTY LINE./A AUTOMATIC DISTRIBUTNGVALVE DETAIL40END CAP IVUSÌ BÉGLUED OR SECUREDIN A WATER TIGHTFASHION WITHUNDERGROUNDSFAI ANTENCASEMENT PIPE40 RIGID ËNDCAP AT EACH ENDOF PIPESOIL PROFILE TEST PIT NO. 1DRILLED IN END01234578I10LEGENDt=l topsoilff ct"yloamlTl sandyl'I loamLINECAP IVUST ONLY BELARGE ENOUGH TOALLOW SEWER LINE TOFIT THROUGHDARK BROWN TOPSOIL^ENCASEMENT DETAIL\j/,--ffiIUEDIUIV BROWN CLAY LOAI\¡'10" DIA VALVE BOXWITH SECURED LIDREDDISH BROWN SANDY LOAM WTHCOBBLES1.5'PVC SLIP X MALEPIPE THREADADAPTER W/CAP1.5" DIA BALLVA.LVE1.5" DIA SCH¿O PVCLONG SWEEP 90'ELBOWNO GROUNDWATER OR BEDROCK ENCOUNTEREDDURING EXCAVATIONINSTALL FLUSHINGVALVÊ ECCENTRIC TOCENTER OF VALVE BOXGEOMATOVER-EXCAVATE TO DEPTH OF SANDY LOAM WÏHCOBBLES1.5' DtA SCH-40 PVCLATERAL^sotls LoG\r,-F6ãE/A FLUSHING VAL\E DETAIL\3,r-ffirtO'Brien Residence24 CR 111Gãrfiêld County, ColoradoProject Number: C1708Date: 0610412022DesignedReviewedby: CBOby: RBDrawnby: DDw4.0Sheet 4 0F 4
1t26n2,2,00 PM qPublic.net - Garfield County, C(J - Property Record Card: R08408/
G)qPublic.net"' Garfi eld County, CO
Summary
Account
Parcel
Prof¡erty
Address
Legal
Dercription
Acres
Land SqFt
TexAreâ
Mlllt€vy
Subdlvlslon
R084087
?463034æ449
?4 I r 1 CnUNTY nn,CARBCTNDALE, Crf, 81ó23
Section: 3 Township:8 Range:88 ATR lN LOTS 18,19(SEC 3),& LOT
1(SEC I0l.ATRACT OF LAND LOCATED tN THE SE1/4OF SECÍ|ON 3
& THE NE1/4OF SECTION 10 CONTAINING.2lAC. +/-, SAtD TRACT
BEINC MORE NARTICULARLY DESCRIBED PER SPECIAL
WARRRANry DEED REC. NO
o.209
0I
79.74l.O
ViewMap
Owner
LUTTRELL, PAUL D & OBRIEN, MAUREEN A
TlCRESTONEWAY
NEWCASTLE CO 81ó47
Land
Unlt Type VACANT RES LOTS - 0100 (VACANT LAND)
SquareFeet 0
Actual Values
AsêssêdYear
Land Actual
lmprovement Actual
Total Actuel
Assessed Values
Assessed Year
Land Assessed
lmprovement Assessed
Total Assess€d
Tax History
2020
$2,364.68
2o2t
s120,000.00
$o.oo
t120,q¡o.q)
202L
$34800.00
$0.00
$34,800.00
xt79
$2,385.72
20.m
$1o8,OOO.OO
$o.oo
f108,0æ.(x)
2020
$31,320.00
$o.oo
$3r"320.q)
2ßta
$77.O4
2o2L
$2,775.æ
Click here to view the tax ¡nformation for this paEgþühg_çerÉSlg-çgg$y lCasulgl5_websjle.
Transfers
TaxYear
Taxes Billed
Sale Date
5/L4/2078
6t4/2æ9
LLnt2007
8/16/2002
9/3t7975
6/3/1968
Deed Type
SPECIALWARRANWDEED
DEATH CERTIFICATE
EASEMENT
EASEMENÏ
QUITCLAIM DEED
WARRANTYDEED
Reception Number
906744
770773
737665
ó09059
269704
247067
Book - Påge
1378-499
o479-O564
0394-05ó9
Sale Prlce
$85,OOO
$o
$o
$o
$o
$o
Photos
https://qpublic.schneidercorp.com/Appllcation.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=9447&Q=359733098&KeyValue=R084087 'lt2
1125122,2:00 PM qPublic.net - Garfield County, CO - Property Record Card: R084087
Nodata avâllableforthefollowlngmodules: Bu¡ldings,Sketches.
aaIrlÕr ilij ¿u¿ìtt!rll,l'ìai
User Pûacv Po-licy
GQP_&Pr:l¡racv Nqtice
lasJ. S ata v pþ4:J1Æ/ -2922-12Æ53 4t4.
[-lcv::ropcil ì;1
C)Fså,s"rdçr
rlL:rst,:i:2.iIi)
https://qpublic.schneidercorp.com/Application.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=9447&Q=359733098&KeyValue=R084087 212
tÐqPublic,net'"' Garfield County, CO
Overulew
-J -
-l
Account
Number
Parcel
Number
Acres
land SqFt
Tax Area
2019M¡[
Levy
R084087
24ó30340no49
Physical
Address
Owner
Address
24 111 COUNTY RD
CARBONDALE
LU I I RT,LL, PAUL IJ ¿i OtsRIIN,
MAUREENA
TlCRESTONEWAY
NEWCASTLECOSTó47
2019Total Actual
Value
Legend
ll.l earcels
Roads
Parcel/Account
Numbers
Highways
- Lim¡tedAccess
- Highway
Major Road
Local Road
Minor Road
Other Road
Ramp
'" Ferry
Pedestrian Way
Owner Name
f,l Lakes & Rivers
- CountyBoundary
Line
$120,000 Last2Sales
Dete Price
5/74/20!8 $85,000
6t4/2W9 $O
87623
0
0
009
79.74IO
Date c¡eat¡.d:7/25f2022
Last Data Uploaded: U25/2O222:7O:57 AM
Deve rooed bvGì *þg,SJdçf
GCC LOFTS LLC
R090046
246303400033
HOLGATE
ETTA L
R090045
246303400025
R450037
24630341 0006
CARBONDALE
TOWN OF
ROW
R082681
246310100090
BAILEY FAMILY INVESTMENT COMPANY lå¡
Å