HomeMy WebLinkAboutPermit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 7484 CR 100 Carbondale, CO _ Parcel No.: _239118100025 Owner Name: Erich Kaiter Owner Phone: 303-817-7445 Designed By: CBO Designer Phone: 720-309-5259 Contractor: Carla Ostberg Contractor Phone: 720-309-5259 Number of Bedrooms: _0 Minimum Tank Capacity: 1,000-gallon OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-7592_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _07/06/2022____________________ Expiration Date_07/06/2023_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by Boundaries Unlimited dated June 27, 2021. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new additional septic tank will serve a proposed garage/barn. The system will consist of a new, three-compartment 1,000-gallon septic tank with a high-head dosing pump in the second compartment set level with access to grade. Effluent will be pressure dosed to an existing septic tank that serves another existing garage/barn. Effluent will be distributed via 1.25-inch diameter Schedule 40 pressure dosing pipe at a flow rate of 80 gallons. Expected drain-back volume is to be 15 gallons. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 07/06/2022 Issued By: Garfield County Environmental Health Department Date