Loading...
HomeMy WebLinkAboutBuilding SpecsAG'€ SE'/UÍ//NEL TALLY HO CONSTRUCTION 145 COUNTY RD 225 RtFLE, CO 81650-9400 Jobsite Address:37s CO RD 352 RTFLE, CO 81650 Datet 10/20/21 Sentinel Building Systems Job lD: 841293 Dear Sir: This letter is to certify that a 170'wide, 120' long gable symmetrical building with â 28'eave height as referenced above and manufactured by Sentinel Building Systems of Albion, Nebraska is designed in accordance with the following loads: Roof Dead Load: 2.5 psf Seismic lmportance Factor: 1'00 Collateral Load: 1.0 psf Seismic Des¡gn Category: B Roof Live Load: 20.0 psf Assumed Site Class: D Rigid Frame Live Load: 12.0 psf Seismic Coefficient: 0.465 (Ss*Fa) Risk Category: ll - Normal ROOF SNOW LOAD FACTORS Ss=0.30 51=0.08 SD5=0'31 Sd1=0.13 Ground Snow Load: 47.62 psf SEISMIC BRACING SYSTEM: Structural Steel System Not Flat Roof Snow Load: 40.00 psf Specifically Detailed for Seismic Resistance Sloped Roof Snow Load (Ps): 40 psf l=1.00 Ce=1.00 Ct=1.20 Cs=1.00 SEISMIC DATA Cs R Terrain Category: C Inter¡or Frame 0.10 3.00 Roof 0.10 3.00 Wind Load: V: 115 mph Vasd: 89.08 mph Left Endwall 0.10 3.00 Exposure C - Closed Right Endwall 0'10 3.00 lnternal Pressure Coefficient: + 0.18 / -0.18 Front Sidewall 0.10 3.00 Wind lmportance Factor: 1.00 Back Sidewall 0.10 3.00 Longitudinal Base Shear (V): 30.31 (k) Transverse Base Shear (V): 28.40 (k) Loads are applied in accordance with the IBC 15 building code. The certifying engineer does not certify that the building code or loads specified are adequate or appropriate for the intended use or location of this building. The buyer ís responsible to verify specified loads are in compliance with the local regulatory authorities. Desígn is in accordance with the applicable sections of the 2010 ANSI/AISC 360-10 and the 2012 AlSl 5100. This certification is limited to the steel framework, the metal roof and the metal wall covering, and fasteners required for their installation. Thiscertificationspecificallyexcludesananalysisofthefoundationandpartssuppliedbyanyoneotherthan Sentinel Building Systems. Sincerely, l\) i ! SENTI NEL BUILDING SYSTEMS Ðavid M. Woebbecke, P.E. Certifying Engineer 237 South 4th Street, PO. Box 348. Albion, NE 68620 TF 8A0327.0790 I P 402.395.5076 I F402.395.6369 | sentinelbuildinss.com ..3 )o'Lï'Ll 6 O El Dtr @assrowthintl I nccnowrs.cov