Dear Sir:
This letter is to certify that a 170'wide, 120' long gable symmetrical building with â 28'eave height as referenced above and
manufactured by Sentinel Building Systems of Albion, Nebraska is designed in accordance with the following loads:
Roof Dead Load: 2.5 psf Seismic lmportance Factor: 1'00
Collateral Load: 1.0 psf Seismic Des¡gn Category: B
Roof Live Load: 20.0 psf Assumed Site Class: D
Rigid Frame Live Load: 12.0 psf Seismic Coefficient: 0.465 (Ss*Fa)
Risk Category: ll - Normal
ROOF SNOW LOAD FACTORS Ss=0.30 51=0.08 SD5=0'31 Sd1=0.13
Ground Snow Load: 47.62 psf SEISMIC BRACING SYSTEM: Structural Steel System Not
Flat Roof Snow Load: 40.00 psf Specifically Detailed for Seismic Resistance
Sloped Roof Snow Load (Ps): 40 psf
l=1.00 Ce=1.00 Ct=1.20 Cs=1.00 SEISMIC DATA Cs R
Terrain Category: C Inter¡or Frame 0.10 3.00
Roof 0.10 3.00
Wind Load: V: 115 mph Vasd: 89.08 mph Left Endwall 0.10 3.00
Exposure C - Closed Right Endwall 0'10 3.00
lnternal Pressure Coefficient: + 0.18 / -0.18 Front Sidewall 0.10 3.00
Wind lmportance Factor: 1.00 Back Sidewall 0.10 3.00
Longitudinal Base Shear (V): 30.31 (k)
Transverse Base Shear (V): 28.40 (k)
Loads are applied in accordance with the IBC 15 building code. The certifying engineer does not certify that the building code
or loads specified are adequate or appropriate for the intended use or location of this building. The buyer ís responsible to
verify specified loads are in compliance with the local regulatory authorities.
Desígn is in accordance with the applicable sections of the 2010 ANSI/AISC 360-10 and the 2012 AlSl 5100.
This certification is limited to the steel framework, the metal roof and the metal wall covering, and fasteners required for their
installation. Thiscertificationspecificallyexcludesananalysisofthefoundationandpartssuppliedbyanyoneotherthan
Sentinel Building Systems.