HomeMy WebLinkAboutScope of Work & Site PlanTo: bra nclon @repa ircracks.conl subject: gL River Bend way ilronbridge) - Grenier Residence - preliminary Findings [20154.HalcombJ Good morning Brandon, Yesterday we conducted the inspection of this property. As it happens, r was out on this same project in December 2020il1.i'åi$"ffiiliff:,',fl:'i;äìïjälj;:'tr'''t ti*". i',Å"'tt,.t"o . spreadsheet *iiripr,otog,aphs/diagrams To summarize: r Grenier's had noticed worsening of cracking in the southwest laundry roomr Grenier's had noticed the cracks in the garage in this area had stayed the same¡ Grenier's didn't report cracking anywhere erse beside the raundry room, Knott's observations and comparing to our 2020 photographs:¡ The crack in the raundry/kitchen wail had been present in zl2obut had worsened.¡ The crack above the laundry wíndow had been present in 202abut had worsened.¡ The cracks in the garage wail had been present in 2020 and were the same.¡ The comparison of the elevation surveys showed the southwest corner at the laundry room was '.3_inches than2020.¡ The elevation survey showed the remainder of the kitchen/dining areas had not effectivery changed since 2020and were within the tolerance of the zip level.r ln the crawlspace' there was a crack/separation in the footing and stemwall near the southwest cornerof thestemwall corner beneath the laundry room.o This is likely historic because recent movement of this magnitude wourd rikely generate much moreinterior distress above, whích was not the case. Knott's preliminary findings on the cause of the laundry room cracking:o The southwest corner of the laundry room as settled downwards 0.3,inches since Decemb er 2020.' nä:tilï,l|:iîtt n pier 24 and 25 below the laundrv room is rerativery unsupporred consideríns the ¡ piers in this region (24,25, 261 may have slipped/shifted slÍghtly.r No Ìndication of heaving soils. Knott's preliminary conceptual recommendations¡ Add (1) pier on the south wall at the SW corner below the laundry room (between 24 and 25, at the corner ofsouth wall)¡ Also' either re-pressurize píers 25 and 26 oR add an addítional pier on the crawlspace side opposite of 25 to re-lift this region. Please let me know if this makes sense and what questions you might have. please ret us know if we can assist furtherregarding this project. Thank youl ,.lF Sam R. Henning, p.E. Prolect Manager s h en n i n g @ lt ¡ri¡ttla b " corr¡ Knott Laboratory. LLC *!"v,**eåurilç Grand Junction, CO M : 303-925- 1900 C: 970-5 49 -7 ZO7 Knþ'n" YEAR ANNIYERSAPY r,â¡oRATOnY LLC Fo¡ensic Fnginee¡¡ng & Aniñralíon For electronic payment we provide a link to a secure payment portal and will never direcily provide norreguest rout¡ng and account numbers via email, KNOTT LABORATORY'S RESPONSE TO COVID-19 Knott Laboratory remains committed to our clients and will continue to perform inspections following current cDCguidelines' Additionally, we continue to use state-of the art "qriprãnì and technology to increase efficiency and to ;""*¡r:J:" time needed for on-site inspections. we ask ou. .ti*tiii rånd un .orr"rpoñå*.å Ël"ctronicalty ;il;;*, from disclosure by have received this Note: This ¡s intended to received and read on lv by certain individuals. It may contain information that is or protectedthe Ëlectron¡c Communications Privacy Act, 18 U.S.C. sections 2510-2521.lf it has been misd irected,or if you suspect you lras taken reãsonã in error, please notify me by ble precaut¡ons to ensure no v¡ruses or malware are present in replying and then delete both the email and reply Furthermore,although Knott Laboratory any loss or damage arising from the use of this email or attachments. this email, Knott Laboratory cannot accept responsibility for This email and any files transmitted with it are confidentialand intended sorery forthe use of the individuaror ceíved this email in error, please notify the system manager 3 whom they are addressed. lf you have re entity to