Loading...
HomeMy WebLinkAboutConditions of PermitCONDITION OF PERMIT B LRE-06-22-7 559 Henry Domville / Jorge Lopez New S/F Dwelling TBD Panorama Dr, Carbondale Panorama Ranches 1't Amendment, Homestead 22 1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATTONAL RESIDENTIAL CODE (l.R.C.) AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.) 2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALLAPPLICABLE ITEMS CONTAINED lN THE ATTACH ED "GARFI ELD COU NTY BU I LDING REOUI REM ENTS". NU M BER REFERENCËS NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTItNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY, 4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICÏ. 5) pRE FABRTCATED ROOF TRUSSES. HAVE ENGINEERING FOR INSPECTOR AT TIME OF FRAME INSPECTION. Site elevation exceeds 7,000 ft. Structural Engineer specifies 50 PSF Roof snowload. ó) opEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING TNSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. STRUCTURAL ENGINEER HAS DESIGNED FOUNDATION SYSTEM AT 2,OOO PSF SOIL BEARING. 7) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSIONAL LICENSED SURVEYOR, IS REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS-BUILT ROOFS COMPLY WITH GARFIELD COUNTY'S 25-FT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE (POLICY GUDE ATTACHED). B) ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS)TO BE INSPECTED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO. PROVIDE ENGINEER'S FINAL REPORT TO GARFIELD COUNTY PUBLIC HEATH PRIOR TO SCHEDULING A FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY. 9) OWNER BUTLDER SHALL REFERENCE THE ATTACHED RESOLUTION 2007-07 RECEPTION NUMBER 716952 FOR FIRE SPRINKLER REOUIREMENTS. OWNER IS ENCOURAGED TO CONTACT THE CARBONDALE & RURAL FIRE PROTECTION DISTRICTS AND A OUALIFIED FIRE SPRINKLER INSTALLER AS SOON AS POSSIBLE. ALL FIRE SPRINKLER PERMITS, SPRINKLER PLAN REVIEWS, ROUGH-IN AND FINAL INSPECTIONS ARE ADMINISTERED DIRECTLY BY THE FIRE DISTRICT. ROUGH-IN SPRINKLER APPROVAL IS REOUIRED PRIOR TO SCHEDULING A FRAMING INSPECTION. FINAL SPRINKLER APPROVAL IS REOUIRED PRIOR TO SCHEDULING A BUILDING FINAL / CERTIFICATE OF OCCUPANCY. 'lhar all rçsidenrial Ètructurûs ¡n all the lots shall be constnrcted with sprinkler ÊyÈrÊm5 in accordance with NFPA l3D - Sl¿rn¡Ír¡rd þr r/re Instnllaríon qf