HomeMy WebLinkAboutSubsoil StudyLKP Engineering, Inc.
CIVIUGEOTECHNICAL
SOIL AND F'OUNDATION INVESTIGATION
F'OR A
PROPOSED RESIDENCE
LOT I, STIRLING RANCH PUD
IOO2 SKIPPER DRIVE
CARBONDALE
GARFIELD COUNTY, COLORADO
PROJECT NO. 21-3550
SEPTI,MBER 18,2021
PREPARED FOR:
KEVIN L. PATRICK &
ANDREA WENDEL
229 M.IDLAND AVENUE
BASALT, CO 81621
RECEIVED
JUt ì 3 trjt?
GARFIELD COUNTY
COMMUNITY NEVELOPMEI,JT
P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 ''vwrv,l..Kl'finginççr:irlg.tûnt
TABLE OF CONTENTS
EXECUTIVE SUMMARY ...,......
SCOPE OF STUDY
SITE DESCRIPTION...,
PROPOSED CONSTRUCTION
IIIELD INVESTIGATION .........
SUBSURFACE SOIL AND GROLINDWATER CONDITION ..
FOUNDATION RECOMMENDATIONS .....,...
SLAB CONSTRUCTION .........
RETAINING V/ALLS.....,.....
UNDERDRAIN SYSTEM
SITE GRADING AND DRAINAGE
LAWN IRRIGATION
LrMITATION................
FIGURES
LOCATION SKETCH
SUBSURFACE EXPLORATION LOGS
SWELL-CONSOLIDATION TEST RESULTS
PERIMETER DRAIN DETAIL.
STRUCTURAL FILL WITH GEOGRID........
..DRAWING NO, 1
..FIGURENO's l-2
"..FIGURE NO, 3
,.FIGURE NO.4
...FIGURE NO. 5
2
2
2
J
J
3
4
5
6
6
7
7
I
LKP Engineering, Inc
EXECUTIVE SUMMARY
The proposed residence should be supported with
conventional type spread footings, designed for an allowable soil
bearing pressure of2000 psf. They should construct the footings
on the undisturbed silty, sandy clay to clayey sand with basalt
rocks or structural fill with geogrid. See Foundation
Recommendations.
SCOPE OF STUDY
This report presents the results ofa subsurfacc Soil and Foundation Investigation for a
proposed residence to be constructed on a parcel ofLand, Account R008776, Parcel
?3g13A40500l, 1002 Skipper Drive, Carbondale, CO 81623, Lot 1, Stirling Ranch PUD,
Garfield County, Colorado. The purpose of the subsurface soil and foundation investigation was
to determine the engineering characteristics of thc foundation soil and to provide
recommendations for the foundation design, grading, and drainage. Geologic hazard sludies
\are outside ofour scope ofservices.
SITE DESCRIPTION
Lot 1, Stirling Ranch PUD at 1002 Skipper Drive is 6.tt7l+/- acres and it is located on
the west side of the Skipper Drive cul-de-sac, Carbondale, Garfield County, Colorado.
Directions to the lot from US Highway 82 are via Catherine Store Road to CR 1 02 to CR 162 to
Skipper Drive to the end of the road at the cul-de-sac. The dirt driveway goes from the Skippcr
LKP Engineering, Inc.
J
l)rive cul-de-sac though an access easement on Lot 2 to the building envelopc on Lot 1.
Vegetation within the proposed building site consisted of sparse grass, juniper trees, small sage
brush, cacti, few pine trees, and basalt rocks. The topography was moderate at the upper one
third and steep on the rest. Drainagc is to the west and southwest. To the north of the lot is an
open space and to the east and west are vacant lots. Lot I was also vacant
PROPOSED CONSTRUCTION
At the time of the soil and foundation investigation architectural plans have not bcen
developed yet. We have assumed that the proposed residence will be two story, wood frame
construction with a possible walkout basement, on a concrete foundation, with an attached
garagc. We anticipate loads to be light, typical of residential construction.
If the finalized plans differ significantly from the above understanding, thcy should
notify us to reevaluate the recommendations of this report.
FIELD INVESTIGATION
The field investigation, conducted on September2,2021, consisted of logging and
sampling two test pits. The test pits were dug by Ryan lvy with Deere 60D mini trackhoe,
Approximate locations of the test pits are shown on Drawing No. 1. We show the soil profìle of
the test pits on the Subsurface Exploration Logs, Figure No's I and 2. Soil samples for
laboratory soil analysis and observation were taken at selected intervals. Geologic hazard studies
are outside ofour scope ofservices.
SUBSURFACE SOIL AND GROUNDWATER CONDITION
The soilprofiles encountered in the two test pits were uniform, consisting of about one
LKP Engineering, Inc.
4
foot of topsoil over I -3 feet of blocky clay over whitish, calcareous, gypsiferous, silty, sandy
clay to clayey sand, gypsiferous, calcareous, with basalt rocks of gravel to cobbles and boulder
size to the maximum depth explored of 5.5 and 4 feet respectively. Ground water was not
encountered in the test pits.
We sampled the soil in the test pits at random intervals.'I'he soil samples were tested in
our laboratory for swell-consolidation, natural dry density, and natural moisture content. The test
results are shown on Figure No. 3.
F'OUNDATION RECOMMENDATIONS
The proposed residence should be supported with conventional type spread footings,
designed for an allowable soil bearing pressure of 2000 psf. They should construct the footings
on the undisturbed silty-sandy clay with basalt gravel, cobbles and boulders, From previous
experience with similar soils, it is very likely that excavation of the large basalt rocks to level the
foundation excavation for the construction ofthe footings, can leave large voids and uneven
subgrade. lf the thickness of the leveling, structural fill is more than 6 to I inches, structural fill
improved with Tensar geogrid, as shown on the attached detail, flrgure number 5, will be
implemented.
The completedþundation excavqtion must be observed and tested by the undersigned
engineer to verifu that the soil conditions encountered during construction are os anticipaled in
this reporÍ.
We recommend a minimum width of l6 inches for the continuous footings and 2 leet for
the isolated footing pads. Continuous foundation walls should be reinforced top and bottom to
span an unsupported length ofat least l0 feet.
The proposed foundation should be set at a minimum depth of four feet below the
{ìnished grade or at the minimum depth required by the local building code. The loundation
excavation should be free from excavation spoils, frost, organics and standing water. We
LKP Engineering, Inc.
5
recommend proof-rolling of the foundation excavation. Soft spots detected during the proof-
rolling, should be removed by overexcavation. Any overexcavation within the proposed
foundation should be backf,rlled, in 8 inches loose level lifts and compacted to 100% of the
maximum dry density and within 2 percent of the optimum moisture contcnt as dctcrmined in a
laboratory from a Standard Proctor test (ASTM D-698). A structural hll, placed under footings
should be tested by a qualified professional.
SLAB CONSTRUCTION
The natural on-site soils, exclusive of topsoiland organics, are suitable to support lightly
loaded slab-on-grade construction. The subgrade for the slab-on-grade construction should be
proof compacted to detect and removc soft spots. They should backfill overexcavated soft spots
and other underslab frll with the on-site soil, free from topsoil and organics, or other suitable
material, compacted to a minimum of 95 percent of the maximum standard Proctor density
(ASTM D-698). Suitable material should be free from topsoil, organics and rock fragments
greater than 3 inches. If during excavationþr the slab-on-grade similar conditions, qs described
in the above foundation recommendations section, with large voids or uneven surjhce are
created, structural fill os-describe above and as shown on the Structural fill with geogrid deløil,
figure number 4 will be used.
The concretc slab should be constructed over a 4-inch layer ofclcan gravel consisting of
-3l4-inch gravel with at least 50% retained on the No. 4 sieve and less than 3 percent passing the
No. 200 sieve.
They should reinforce the concrete slab-on-grade and score controljoints according to
the American Concrete Institute requirements and per the recommendations of the dcsigner to
reduce damage due to shrinkage. The concrete slab should be separated from the foundation
walls and columns with expansion joints to allow for independent movement without causing
damage.
LKP Engineering, Inc.
6
RETAINING WALLS
Foundation walls retaining earth and retaining structures that are laterally supported
should be designed to resist an equivalent fluid density of 60 pcf for an "at-rest" condition.
Laterally unrestrained structures, retaining the on-site earth, should be designed to resist an
equivalent fluid density of 40 pcf for the "active" case.
The above design rccommendations assume drained backfill conditions and a horizontal
backfill surface. Surcharge loading due to adjacent structures, weight of temporary stored
construction materials and equipment, inclined backfill and hydrostatic pressure due to
undraíned backfill should be incorporated in the design. They should try to prevent the buildup
of hydrostatic pressure behind the retaining wall.
Passive earth pressure of360 psfcan be used for the lateral pressure against the sides of
the footings. Resistance to sliding at the bottom of the footings can be calculated based on a
coefhcient of friction of 0.5, Undisturbed soil or a structural fill compacted to 100 percent of the
maximum dry density and within 2 percent of the optimum moisture content will be used to
resist lateral loads at the sides of the footings.
UNDERDRAIN SYSTEM
To reduce the risk olsurface water intìltrating the f'oundation subsoil, we recommend
installation of a foundation perimeter drain (see Figure No. 4). The foundation perimeter drain
should consist of a 4-inch diameter, perforated pipe, sloped to a suitable gravity outlet, aT. a l14
inch per foot for flexible or at a l/8 of an inch for rigid pipe. The bottom of thc trench adjacent
to the footing should be lined with a polyethylene moisture barrier glued to the foundation wall.
The drain pipe should be covered with a minimum of 6 inches of -3l4-inch free-draining
granular material. Geotextile (Mirafi l40N or equivalent) should be used to cover the free-
LKP Enginecring, lnc.
7
draining gravel to prevent siltation and clogging of the drain. The backfill above the drain should
be granular material to within 2 feet of the ground surface to prevent a buildup of hydrostatic
pressure.
SITE GRADING AND DRAINAGE
The following recommendations are general. Exterior backfill should be compacted at or
near the optimum moisture content to at least 95%o of the maximum standard Proctor density
under pavement, sidewalk and patio areas and to at least 90% of the maximum standard Proctor
density under landscaped areas. They should use mechanical methods of compaction. Do not
puddle the foundation excavation.
The site surrounding the building structure should slope away from the building in all
directions. A minimum of l2 inches in the first l0 feet is recommended in unpaved areas, and
three inches in the first l0 feet in paved areas. The top of the granular foundation backfill should
be covered with a minimum of 1 foot of relatively impervious fìll to reduce the potential of
surface water infiltrating the foundation subsoils.
Surface water naturally draining toward the proposed building site should be diverted
around and away from it by means of drainage swales or other approved methods. The roof
drains and downspouts should extend and discharge beyond the limits of the backfill.
LAWN IRRIGATION
It is not recommended to introduce excess water to the foundation soils by installing
sprinkler systems next to the building. The installation of the sprinkler heads should ensure that
the spray from the heads will not fall within l0 feet of foundation walls, porches or patio slabs.
Lawn irrigation must be controlled.
LKP Engineering, Inc.
I
LIMITATION
This report has been prepared accordíng to locally accepted Professional Geotechnical
Engineering standards for similar methods of testing and soil conditions at this time. The type of
soil testing was selected by the owner and general contractor as the preferred method for the soil
and foundation investigation over a soil and foundation investigation with a drill rig. There is no
other warranty either expressed or implied.
'l'he findings and recommendations of this report are based on held exploration,
laboratory testing of samples obtained at the specific locations shown on the Location Sketch,
Drawing No.I and on assumptions stated in thc rcport. Soil conditions at other locations rn{y
varv. which mav not becomc evident untilthe foundati!¡n excavalign is completed. lf soil or
water conditions seem different from those desuibed in this report, we should be contacted
immediately to reevaluate the recommendations of this report. We are not responsible for
tcchnical intcrprctation by othcrs of the data presented in this report.
This report has been prepared for the exclusive use of Kevin L. Patrick & Andrea
Wendel, for the specific application to the ir proposed residence on Lot l, Stirling Ranch PUD,
1002 Skipper Drive, Carbondale, Garfield County, Colorado.
Sincerely,
LKP ENGINEERING,INC.
,***o.- l.t?ú
,,
.3] :'..:f)r rrr; r'i',' i,
i i.ì
.
M,;,Wu',ii,: ilii,i.i,*
Luiza Petrovska, PE
J:\*WP X4-LKP\ 2021\2 I -3550CLAY-SAND-BASALT-PITS.DOCX
LKP Engineering, Inc.
Þ
ll/
-
/, PROF-I/\ (Þ
(F) \€urrÞÍ.Jc
Ji.'r-ı .--f -7
ENVËLOPE
/enor z
\
I
I
I
SK¡PPER
DRIVE.i\TEST
PIT, 1
"(Þ
/
/
PLATEAU ^r/\/
/
/
--'-a_ n /
/\
/
/
I
/
/ì
/
(
/
/
,/
NOTE: THE LOCAfION OF IHE lÊST PllS JS
APPROXIMATÉ IT IS ÑO' SASED ON A SURVEY
LOCATION SKETCH
CMLICEOTECHNICAL
2 I -3550
- l" = 100'1OO2 SKIPPER DRIVE
CARBONDALE
GARFIELD COUNTY, COLORADO
glneenng,nc.
com
P.O. Box 724, Íogle, CO 816J1
lel (970) J90-OJ07 www,
Test Pit f 1DATE OBSÊRVED: SEPTEMBER 2, 2021
ELEVAÏON:
LABORATORY.IEST RESULTS
REMARKSDEPTH
FEET
s
Y
M
B
o
I
s
A
M
P
L
E
DESCRPNON OF MA\ERIAL
AND SAMPLE LOCANON
N
,,W
OD: 76.6 pcf
MC= 13.3 Ztr
Topsoil with roots
Reddìsh-brown, blocky clay wÌth
bosolt cobbles ond boulders
Whitish, silty, clayey sond,
col coreous, g¡rpsiferous
Bosolt rocks
No Ground Woter
Encountered
Refusol of 5.5 feet on bosolt
boulders
_t0
-15
_20
5
- Bulk Somple
- Noturol Dry Density (pcf)
- Noturol Moìsture Content
- Percent Possing No. 200
- Lìguid Limit
- Plosticity lndex
- Ground woter
trI
DO
MC
LL
PI
GW
(z)
Sieve-200
LEGEND:
- 2-inch O.Ð. Colifornio Liner Sample
PRO,ECÍ NO.:2t-3550
SUBSURFACE EXPTORATION tOG ndnÊ tfrJ ItKP ENGINEERTNG, INC.
Test Pit ¡f; 2DATE OBSER\ED: SEPTEMBER 2, 2021
ELEVATON:
LABORATORY
TFST RFSU¿ß
REMARKSDEPfH
FEET
s
Y
M
B
o
L
5
A
M
P
L
E
DESCRPNON OF MA|ERIAL
AND SAMPLE LOCANON
Topsoil w¡th roots
Reddish-brown, blocky cloy
WhitÍsh, sílty, gravelly sand, with
volconÌc cobbles and boulders,
colcoreou s, gypsìferous
_15
_20
10
5
Refusol of 4 feet on bosolt
boulders
No Ground Woter
Encountered
- Bulk Somple
- Noturol Dry Density (pcf)
- Noturol Moisture Content
- Percent Posslng No. 200
- Liquid Limit
- Plostìcíty lndex
- Ground woter
(z)
Sieve
tlI
DD
MC
-200
LL
PI
GW
- 2-inch O.D. Colifornia Liner Somple
I,EGEND:
PK ECf fiO.:2t-3550SUBSURFACE EXPIORATION LOG nffiNa:2I,KP ENGINEERING, INC.
Ã
4
z
2
o
-l
c.3 -2co
a.
l!
-3
b\
-4
s
.9Vttvr -¿
P
a_
Eoo-6
-7
-8
-9
-,0
-11
-12
Swell - Consolìdotion Test ResultsEngÍnsælng,ila:J
AWAY FROM BUILDING
BACKFILL WITH A MINIMUM
OF ONE FOOT OF RELATIVELY
IMPERVIOUS SOIL
GRANUI-AR F/{.1"
TER FABRIC (MIRAFI
14ON OR EQUIVALENT)
3/4.INCH DIAIVETER, COARSE,
CLEAN CRUSH ROCK
30 MIL MINIMUM THICKNESS,NCH DIAMETER PERFORATED PIPE SLOPED TO
PLASTIC LINER, GLUED TO A DAYLIGHT LOCATION AWAY FROM THE
FOUNDATION AT .I/4-INCH PER FOOI FOR
FLEXIBLE AND 1/8.INCH IVfNIMUM FOR RIGID PIPE
FOUNDATION WALL
¡ Þ rtollNt;
Þ
Þ
Þ
Þ
Þ
Þ
¡
Þ Þ
\J
s
È
\
:Iot-
PERIMETER DRAIN
CTVIL/GEOTECIÍNICAL
21-3550
scALE: N,f ,s.
J90-OlO7 www.LKPEngineering.comlel
t
P.0. Box 724, Ecqle, C0 816J1
1OO2 SKIPPER DRIVE
CARBONDALE
GARFIELD COUNTY, COLORADO
OVE REXCAVATI ON-STR UCTU RAL F I LL
AND GEOGRID
N.T.S,
5'mtn
oulside
MINUS 3/4.INCH CLEAN CRUSH
ROCK (for under slab on grãde
TËNâAR TriAx
UND¡STURBED TXI 50
INUS 3-INCH ROAD BASE OR OTHER
SUITABLE STRUCTURAL FI LL
APPROVED BY THE ENGINEER
NOTE:
1. EXCAVATE THE TOPSOIL AND OTHER UNSUITABTE SOIL
2. BACKFILL W|TH 6-INCHES OF STRUCTURAL F¡LL
3. CONSTRUCT THE FIRST LAYER OF IENSAR TTiAx GEOGR¡D OVER THE STRUCTURAL FILL
4 CONÎINUE WTH THE STRUCTURAL FILL AND TENSAR GEOGRID TO WITHIN 6.INCHES OF THE BOTTOM OF
SLAB ON GRADE ELEVATION.
5, BACKFILL OVER THE LAST LAYER OF GEOGRID WITH 6-INCHES OF MINUS 3/4-INCH CLEAN CRUSH ROCK,
6. ANY SUBSTITUTIONS MUST BE VERIFIED WITH THE ENGINEER,
rHE GEOGRID AND GEOTEXIILE PLACEMENT WILL BE ACCORDING TO THE MANUFACTURERS
RECOMMENDATIONS,
FOR STRUCTURAL FILL PLACEMENT OVEREXCAVATE:
4 FEET BELOW THE PROPOSED FOOTINGS ELEVAÏION
3 FEET BELOW THE PROPOSED SLAB ON GRADE ELEVATION
SLAB ON GRADE
I
STRUCTURAL FILL WITH GEOGRID
PROJECI NO
21 -3550LOT 1, STIRLING RANCH PUD
CItrIL,/GEOTSCHNTCAL
SCALf
N.T S,IOO2 SKIPPER DRÍVE
CARBONDALE
GARFIELD COUNTY, COLORADO FIGURE ÑO
5
,
comTel390- 0307
P.O. Box 724, íaqle, CO 81631