HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-0 6-22-7567
BENJAMIN & SUSANNA ALTER
SINGLE-FAMILY DWELLING WITH ATTACHED GARAGE
789 HIDDEN VALLEY DR, GWS
SPRINGRIDGE RESERVE, PH. 3, LOT ó1
1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATIONAL RESIDENTIAL CODE
(r.R.c,)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED
IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER
REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST,
3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC
BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION.
ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION &
CERTI FICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION
AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE
AND LOCAL FIRE DISTRICT,
5) PURSUANT TO ATTACHED RECORDED PLAT NOTE #ó -- AND A PROPOSED
BUILDING OVERALL FIRE AREA IN EXCESS OF 3,óOO SOUARE FEET -- THIS
PROPERry SHALL INCLUDE A FIRE SUPPRESSION SYSTEM. FIRE MARSHAL GREG
BAK INITIAL SIGN OFF OBTAINED FOR RELEASE THE BUILDING PERMIT FOR
ISSUANCE. FIRE SPRINKLER ROUGH-IN INSPECTION APPROVAL IS REOUIRED
BEFORE FRAMING INSPECTION. FINAL FIRE SPRINKLER APPROVAL REOUIRED
PRIOR TO BUILDING FINAL / CERTIFICATE OF OCCUPANCY. (SEE ATTACHED
DOCUMENTS),
ó) OPEN HOLE SOILS REPORT lS REOUIRED AT FOOTING INSPECTION BY
GEOTECHNICAL ENGINEER, 4,OOO PSF SOIL BEARING.
7) A LOT IMPROVEMENT CERTIFICATED, SEALED BY A COLORADO LICENSED
SURVEYOR, IS REQUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE -
INCLUDING ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS - IS IN
COMPLIANCE WITH MINIMUM SETBACKS AND/OR BUILDING ENVELOPE
REOUIREMENTS,