HomeMy WebLinkAboutOWTS DesignREGEIVED i:i,i il i :i,1,:f GARFIELD COUNTY COMMUNITY DEVELOPMENTcr-ì(),,-.129 CAINS I*ANE CARBONDALE,CO 41623 970.309.5259 CARLÄ. OSTBERG@GMAI L. COM, Fit,:r,'¡'t( ('( ):i¡i{'l,'l'l¡l'{ ; June 17,2022 Project No. C1724 Mike Podmore podmoremichael@gmail.com Subsurface lnvestigation and Onsite Wastewater Treatment System Design 3-Bedroom Residence Lot 1, Rapids on the Colorado Garfield County, Colorado Mike, CBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system (O!AfIS) design for the subject residence. The 3.65-acre property is located outside of New Castle, in an area where OWTSs are necessary. Legal Description: Section: 4 Township: 6 Range: 91 Subdivision: RAPIDS ON THE COLORADO Lot: 1 Parcel lD: 2181 -043-07-001 SITE CONDITIONS The property is currently undeveloped. A 3-bedroom residence is proposed The residence will be served potable water from a community water system. There were two wells on the property which have both been abandoned. There is an 8-inch water line that runs to a fire hydrant and water tap to the southeast of the proposed residence. The sewer line will cross this water line. The sewer line must be encased at least 5-feet of each side of the crossing (See W4.0/3 Encasement Detail) The proposed soil treatment area (STA) location is relatively flat and vegetated with native grasses. No topography was provided. The area generally slopes to the north toward the Colorado River. There should be no traffic or staging of material over the future STA site to avoid compaction of soils prior to construction of the STA. SUBSURFACE The subsurface was investigated on May 18,2022 by digging two soil profile test pit excavations (lest Pits) A visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.l The materials encountered in Test Pit #1 consisted of medium brourn sandy loam to a maximum depth explored of 7.S-feet. No bedrock or groundwater was encountered. The materials encountered in Test Pit #2 consisted of medium brown sandy loam to a maximum depth explored of 6.0-feet where practical digging refusal was encountered on a boulder. No bedrock or 1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOWVisual and Tactile Evaluation of Soils Training. Page 2 groundwater was encountered. A sample of the soils was taken from Test Pit #1 at 3-feet below grade. Soil structure grade was moderate. The soil formed a ball and a ribbon f -inch in length before breaking. Soil structure shape was blocky and consistence was friable. Soil texture was gritty. STA sizing is based on SoilType 2, Sandy Loam with moderate slructure grade. A long term acceptance rate (LTAR) of 0.6 gallon$ per square foot will be used to design the OWTS. Test Pit #1 looking toward future house location Test Pit #1 \:- ., Test Pit #1 Page 3 'a t à !l Backfill Sieved sample Ribbon approximately f -inch Page 4 " .,y' s- \€ Looking toward Test Pit #2 (lo the northeast) / sidewall .-''1 ! :r'.r ..,.: -l.\{ t-l' ,.ã', if{ Test Pit #2 Backfill DESIGN SPECIFICATIONS Design Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms = 4b0 GpD LTAR = 0.6 GPD/SF 450 GPD / 0.6 GPD/SF x 1.0 (gravity trenches) x 0.7 (chambers) = S2S SF The OWTS design is based on 3-bedrooms. An average daily wastewater flow of 450 GPD will be used. Forthe purposes of this OWTS design, Benchmark Elevation has been established as 100'as the Finished Floor of the residence. CBO lnc. should be notified of any discrepancies or problems with grade elevations of proposed components during installation of the OWTS. Minimum ElevationOWTS Component Approximate horizontal distance 8' / min. 2o/o fall I min. 2" fall Primary Tank lnlet lnvert Approximate horizontal distance 103'/ min. 1o/o fall i min. 12.875" fa$ Automatic Distributing Valve / Distribution Box Approximate horizontal distance to furthest trench 27' I min. 1o/o fall / min. 3.375" fall lnfiltrative Surface Page 5 levations are based upon standard installation practices. Component elevations may change during installation due to site conditions. Minimum grade refers to piping between components. The 4-inch diameter SDR-35 sewer line exiting the residence must have a double-sweep clean out and a minimum 2o/o grade to the septic tank. The system installation must include a 10O0-gallon, two-compartment septic tank (state-approved concrete or poly) with an effluent filter on the outlet tee. We have provided specifications for a 1000- gallon, two-compartment lnfiltrator@ poly septic tank. Risers must bring the manhole lids to grade for access. lf more than one riser is added to the septic tank, an extension handle must be installed on the effluent filter. Effluent will gravity flow to a distribution box, and then to four gravelless chamber trenches. The distribution box must be accessible from grade and must have flow equalizers, or similar product, installed on each outlet pipe in the distribution box to assure equal flow to each trench. Each trench will consist of 1 1 'Quick 4' Standard Plus lnfiltrator@ chambers for a total of 44 chambers and 528 squâre feet of infiltrative area. There must be at least 4-feet of undisturbed soil between each trench. lnspection ports must be installed at the beginning and end of each trench. Ports may be cut to grade and placed in sprinkler þoxes for access. COMPONENT SPECIFICATIONS The component manufacturers are typical of applications used by contractors and engineers in this area. CBO lnc. must approve alternative components prior to inskllation of the OWTS. Requests must be submitted, in writing, to our office for approval prior to installation. Component technical data sheets are available upon request. Construction must be according to Garfield County On-Site WastewaterTreatment System Regulations, the OWI-S Permit provided by Garfield County Building Department, and this design. COMPONENT MANUFACTURER MODEL NO.COMMENTS Septic Tank Valley Precast or lnfiltrator@ Item # 1000T-2CP or Item # 1060-2CP 1000-gallon, 2- compartment septic tank Risers and Lids Orenco@ Douþle-walled PVC risers and lids Effluent Filter Orenco@ 4-inch diameter Fullsize Distribution Box Polylok Distribution box, lids, rises, and (4) flow equalizers Chambers lnf¡ltratoKD standard Plus 44 'Quick 4' Pnge h INSTALLATION CONTRACTOR CBO lnc. expects that the installer be experienced and qualified to perform the scope of work outlined in this design. The installer must review this design thoroughly and coordinate with our office in advance of installation. Any additional conditions in this design or county permit must be completed and documented prior to final approval of the OWI.S installation. Communication between the installer and this office is expected throughout the installation. INSTALLATION OBSERVATIONS CBO lnc. must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. CBO lnc. should be notified 48 hours in advance to observe the installation. ln an effort to improve the accuracy of the record drawing, we request that the installer provide a sketch of the installation, including path of the sewer lines, water line installation (if applicable), septic tank location, STA location, and measurements from building corners or another fixed objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design Packet. Photographs of the installation and final cover are also requested to supplement our installation documentation. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWI-S installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, altemating STAs, and any other components needing maintenance. Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing flxtures should be checked to ensure that no additionalwater is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. lf the OWFS consists of a pressurized pump system, we recommend the laterals be flushed annually, oras needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. PageT ADDITIONAL CONSTRUCTION NOTES lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high- water conditions and shall be connected to a control breaker separate from the high-water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill overthe STA must be uniform and granularwith no material greaterthan minus 3-inch. LIMITS: The design is based on information submitted. lf soil conditions encountered are different from conditions described in report, CBO lnc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions Sincerely, CBO lnc. (t¿rt; t¿t tistúr.r 6 Carla Ostberg, MPH, REHS C8O lnÊ121 Cains LaæCaöondde, Cdo.a& 81623PiDne 9/0-3O9-5259cala.æþ€rg@rf8ilcomFire hPROPOSED(.\(3-BEDROOMRESIDENCEAddrtronol 3to be retoined otof property.SEPT|Q_Fourc rebor with plocoF,, PLS No. 7972BUILDINGt-\\\ABANDONED.0ld house\ shed towell/r\be\ demolishedl1/oter serrriWoterk)Utilfty, droínoge ond irigoii.rneosements per plot (Rec. No.td-FIREJow0l89'FoundNo.5rebor qt fencec0rnerTHE LOC 'IION OF PROrcSED Ii,I'ROVEIJENIS SHOI,VN AREñIOT THE ìESI.ILT OF Á PROPERTY SURVÊY. TTIE LOCATIONSiARE APPIOXIÀ'IATE. lT S THE HCÍ\,IEOWNERS' DUTY TOENSURE ÀLL C0{STRI.ET|ON AND IMPRO\ÆMENT LOCATIONSARE ACÎURATE PROPERTY LINESAI{D STBACKDISTAI{CES,. "STIOULD BE CON¡HRMED PRICR TO Ð(CA\¡ATÍON- SCÀLEDFOR PRI¡fIlr¡G ON 1 1' X 17' PAPER.Wire fenceReocoted irrìgction lìneA SIÏE PLANDRAIVINGS MUST BE TJSED INCONJUNCTION WITH )ESIGNLETTER DATED 06117ø?2.2.+21.96Podmore / Moretti ResidenceLoa 1, Rapids on the coloradoGarneld County, ColoradoProjec{ lúJmber: C1724TPl(,4mãISTAThe Rapidr on the ColgradoSubdivision ¡s Amendèd(Rec. No. 639203)Jdrî ve w oy(3.65 acrec)Lot L-- (,O.LINE^k)-\lRNob7Y203\TP2\LDale: úl1t2onDeslgned by: CBODrãwn by: DOw1 .0Sheet 1 0F 4coP,PLS No. 1J501 - Witness cornerNwoterservtcevolves(heodLINEhone ond I ectric servìceUiiiity, droinoge ond irrigoiioneosements per plot (Rec. No. 6J9203)SCALE: 1 = 5O'=0"O UTILITY, DRAINAGEANDEASEMENTFound rebor witn olum.cop, PLS Nc. 135û120'Droinoge eosementer ploï-No. 6J920J)IFound rebor*,íth olum. copNo.13501ON335ßÀPDS CBO lnc.129 Cains Lânocã¡bondale, Cdorado 81 623Phile 970.309,5259cârla.oÊtberg @gmil.@mPROPOSEDS,BEDROOMRESIDENCEPROPOSED},BEDROOMRESIDENCE5'MIN TOBUILDINGLot I, Rapids on the Co¡oradoGarlield County, ColomdoProjec{Numben C1724Podmore / Moretti ResidenceDø[e: 0611712U22EÞsigned by: CBODrawn by: DDN4" DIASDR.35 SEWER PIPEWITH CLEANOUTMIN 2% FALL TO TANK-\\\\ \--8'DIAWATER LINE, $DEEPSGALE:1'= 20'{'TWGCÆMPARTMENTSEPTIC TANK WTH EFFLUENT SCREEN\.\\_4'DIA SDR€s SEWER LINE TO STA(MrN. r% FALL TO STA)'\\LINEWATER LINEMINTO':UTILITY, ÐRAINAGE,CLEAN OUT EVERY100'MtN.WATER LINE----)AND IRRIGATION E¡ISEMENTîP2+SCH.40 ENCÂSEMENTPIPE EXTENDS 5 ONEACH SIDE OF WATERLINE CROSSING\.\\'--.4'DtA SDR-35 |NSPECI|ON PORTAT - -BEGINNING AND END OF EACH TRENCHTP1BUILDING ENVELOPEWATERTAPANDWATER LINETORESIDENCEgEm2.'QU|CK.4' CHAMBER TRENCHES.4 TRENCHES wlTH 1 I CHAMBERS PERTRENCHFOR A TOTAL OF 44 CI.I,AMBERS AND 528 SF.4" DIA SDR-35 SEITYER LINE TO EACH TRENCH(MrN. 1% SLOPE TO TRENCH)FIRE HYDRANTANDWATERVALVEDISTRIBUTION BOXWITH ACCESS AT GRADEì^PROPOSED OWTSIìSheet 2 0F 4w2.0 GBO ina129 Cãiß LánéCabondale, Colora(b 816?3Phone 970.309"5259cârla.o6tbêr9@mâ¡ LcoñrEND PLÂÎEGRAVEITESS ,(¡ulctG4CfiA¡t¡8ER (4 x Ð4¡ DIA SDR35EFFLUE¡¡T PIFÊ TNOUSEPTIC TA¡¡KDISTRIBUT]ON BOXwlTHDIA SDR-35GRAI]ÊINSPEGfIONPORfÐtA sDR-35 DtSlRtBUlrONA',LINS TO EACH TRET{CH(MtN. f 9å SLOPE TO TRENCH)so¡Lï.PIPES PL.ACED IN10Þ ÞoRTOFCHAÀ4BER ËNDPLATESEXCAVAT]ON',XLrlCK4ffitrycFt,rÀ,tËER (4',xÐfî\ CTIAMEER TRENCH SEC'IIONLtr----'-'---T@DIA SDR-36 INiPECTIONPffiT AT BÊGINNING AI'IDEND OF EACfI TRENCH/I CfIAITBER IRENCII PL.AN\r,-ffiVALVE Co\rERBOXOR rRRlGqflOi¡VATVE BOX ÀI GRAÞEFINISHED GRÁDEOR THREADÐBOX AND COVER, BROUGHT TO GRAÐEÐLFÁNOUÎ AASEMBLY24'MtN.CONCRETECOT'PACT4'DIA SDR-35 SEWERffiffi-BA¡'E TO sUPPORTBôXPIPE CUTTOFIT(MrN 2% SLOPE TO TANKMrN. 1%TOSTA)US€ HOLE ÊAW T)CUT TTIRU TOP OFSCREENEDEt{oORSAND FORBEDDING3'MlN.8" MIN-BAFFLE ORANGLED PIPE/IDISTRIBUTION BOX\¿,-æTO BE USEDAT INLETATRENCTI DETAIL\z¡-----'-----"'Æ\ DISÍRIBU'ÍICI'I BOX DFÍAIL\zr_--_-__ffiaræ1 I Cfl¡{iIBER.S PËR TRB.ICHéOUTLEÏSooooPodmore 1 Moretti ResidenceLot 1, Ræids on the ColoradoGarfield County, CobradoP¡ojed Numben C1724w3.0Sheei 3 0F 4 DESIGN+ãÊDROOil RESTDEI{CEr¡5 GPÐ x 2 PERSONS/BEDROOIT,I x3 BEDROOMS)WÄ,STEWÂTÊR FLOW = /ts! GPDowTs coMPoNENrs ¡¡¡ÞPHYSICAL FEATURESMINIMUM REQUIREDSETBACKÀPPROXIMATE PROPOSEDSETBACKHOUSE TO SEFTIC TANK5'SEPTIC TANKTO WELL50'NIASÊPÎIC TANKTO RIVËR50167STATO HOI.JSEñ7$STATOì,VELL100'N/ASÍATO RIVER50'271'TANKMIN- ,IOOO GALLONSUSE lOOO.GALLON. TWO-COMPARTMENT SEPTIC TANKSOIL TRFáTMENT AREà (STA);LONG TERM ACCEPTANCE F*4rE (LTffi) = 4.6 GAU SFGRAVIÍY, TRENCHES = 750 SF X 1.0 = 750 sFCHAMBERS = 750 SF X 0.7 = 525 SF / f2 SF / CHÀMBER = ¡t4 CHAMBERSFOUR GRAVELLESS CI-IAMBER TRENCHESI 1 'OUICK 4' CHAMBERS IN EACH TRËNCHTOTAI- ,I4 QUICK 4' CHAMBERSSLIP-ON Fr'CDO NOTGLUEINSULATEDTRACERWREFINISHED GRADE$OIL PROFILE TESI PIT NO. ISOIL PROFILË TEST PIT NO.24" DtÀSE$'ERLINEFUuLTruo-0Elt-i: MEDTUM BRowN SANDYLoAtT¡r[*H- Drc,GrNc REFU.AL oN A Bouu)ERMEDIUM BROWN SANDY LOAMLEGENDffi mnoytmTOTA¡IKHOUSE4567II10ACTEAN OUT DETAIL\ár-rüæENCASEMÊNTPIPEÊND CAP MUST BEGLUED OR SECUREDIN AWATÊRTIGHÍFASHION WITHUNDERGROUNDSEATÂNT40 RIGID ENDCAPATEACH ÊNDOF PIPÊNO GROUNDWATER OR BEDROCK ENCOUNTEREDDURING EXCAVATIONDRILLED IN ENDDIA SDR-Js SEV!'ER LINE.CAP MUST ONLY BËLARGE ENOTJGHTOAIIOì,YSEWER LINE TOFfTTHROUGH^sols LoG\rrrcMUST RESTON BOTTOMOF ENCASEMENT PIPE^ENCASilENT DETAIL\y trþffw4.0Sheet 4 0F 4Dalßi O6l17nO22Designed by: CBODrawn by: DDPodmore / Moretti ResidenceLot '1, Rapids orì the ColoradoGarfield County, ColoradoPro¡ecf Number C1724CBO lnc.129 Câin6 LaneCaôondale, Cobrådo 81 623PhoÌìe 970.309.5259carla.ostberg@gmail.com SurvCo, Inc.!-f 9f $qþleuê¡g*qs¡lelr rglslylsçg-SÉruíng Wêste CÐJorodo s/nce t99t"A2è- : .,:l i."crt a'.'e.i."ir'ç-r'.t.c 3.r' :,!r, l!:. 8: iti:t.. ;¿ /ù1^):)CËAPHI| SCALEhtffit Lwthù Cqtñ6h(CatiftÛtlø Èßot io CR.s 38-5f-108)ir:acr ,ê¡i!;) ilai ii:: ni!vc:rctt :acci,¡i tÈriÍic!ie rcs ar€ia.:a :i:_:rri,r f: '!r l_isa li.e'ti:!i:; c:i Valai frCiîJ.:, ::oi i: iS rol a iôraJ!',€/ iirì Cr ¡ai a.,i ì[:i i ji fai ;n ]a ro ¡C rptr i¡"::t esicr:tfreii ai:eria, !-i{¡', lr C:le. l!ir'g ir:.Cvir:îl;¡iÈs-_s ;e¡lilc:l.t is uili sr I i:: Jja rf Li5o ,01! ii¡.tii; c1a Siln€l )crrar"c¡. j€5cr:brs i5e r¡r:ns rpie--rj.i€ 0r Llc,ch rij, ?î2:.a.ie, \l.rci i-i Ziì22, *i.ai .iiii:i a.:¡,aalìtrs. ar: e.i'ey ?¡ìiil ile Þrli(or'e¡:' :a :J":9, +rfepl :! l tn_. _.ci l.e'. l-i i ¡-i oj: a;.t: -a1.. :-L- (?;-.itr:î-?-!C! :,:a:1 17 'l¿a.!i. a.a:':t .¡t'. I'C O:¡:.Þ. r, ar3: 11" :: ::.:t::e-ð': crJsiia .' ::'1e.'0 :at:0r: c il : t:rce, iy:¿:: :s rJ:(C.:r: 5n:r!e I '-¡€cs;oa tiao iìcsìreij P¡iiÊr!'øq/ "it i c.l" :r :ii,:, '.: i: "(i lrllr ,¡!r-cri^oå/ ^ \y."-¡$¡. ".- . ' :- - lt '-'c-'€.'1I - r'. :^.!"-r¡c-/¡(ii,ic.!: ¿cle1n.;ligh Ml¿¡l¡.e oiColmdo R*r* lcccad bv æ*e1 04-ùl-20Ì 6|Íüril;¡l-Í:¡r¡¡ .¡rc¡ + lr t ¡rl.rm :cl.r:) lC. i:U, - lilials: ;La arnil¿r rdii!e !1r;es( rñ F¡['r )I irch,,' B0 fi..ì"iii i!, rr¡cç¿ irí ¡i4r::c^Ècsyrcrt! psr rri ile. ¡{0. i,3ç1:lil-5:ì ra ;îj ioih1¡:. i :. -:i,,1\iç!,ì¡ rtbii qitlcaî, ir':S \â'lt .i " i\: |". .r,)ì:ir a'ìí r' tÊrÈii ri ::r¡rå. rr¿ i{ t.iað ir"ia,ilin-i.!! c; r(rii'ircii,rì \1c'.f il¡. :l::ilillili lrcxirrje ,ì1i I'r iaicrcolcreiir, pei iJoi 1ft!:3. i\ü.r4rt;l¡òti! lPMLto C.Rs. 13-80-105Ìrliciti.i iì :;a)fr(J itr* :?ar :!: a:rneiac q.! ira.i r(iic,, ¡çs¡¡ rÕir !¡ilr a€;cLì ìn i¡liÍp.1itî!ri lú;ii;r!r Ùn'lifi-0.Ê r1"i. lrr!p ¡e.rs.ii!. '¡L'irJl listcror ícr {€i!rì.,¡r .a:!,, -Ç! qrì! tair,r'i:Js;i r?a. !n! Ctieai i. lljia. i:r.çvelnEri !aùrirCn ilt"::ÍCCr¿:dLjJrìñt¡!rìc aÌare tij¡ t¡f jaC., Í.i.r. t.ae dctg ¿i ceili,!ii9. tfCÌi l.aaeo¡.c !;'lcilr È.veltle)'¡cùr,l üc 5!lill rttriliel-;t¡rsiFi-Lot 1Tlc Rapidr on ti¡c Coloftdo^nend¿diRe.. \o. 6J9:03i(3.65 3(rcr)l¡gt dæqþtiæ:r:ì:r! ;:jilas if lre':1a'attlaa:ar!i., ìc re arì¿.aÉj !Ì{'tl,rer' at il,c i.. .cù.ijlrì. 14 zíri-ì ,.xcsf ì+;epl.n. s4. 6Jn::j,,t ':: ! .,'J e t\Shd odeæ'ier C4si:e dC ! ô4ì{":t !:lìi. r!,ii.lpc 'inìiisilitla!J' ì . c' 30.f €l¡¡:tir i' iala€rImprovemcnt Location CertificateLot 1, The Rapids on the Colorado SubdivisionAs Ärncnded$ituated ín the SWi/4 Section 4Township ó South, Range 91 West of the 6th P.M.County of Garfield, State of ColoradoiltI lr'.-tl---irir:sii, .op, f;LtGarfie\dCountYRoadNo. 335S¡¡qs's ñilæl) ii;s lñr.)Éreni io.a!ro. l?.Ìla¡ìe c.e:1a:.er.ls?r1 o tjilÉ reaial l! :.r!l!.¿ t,'fìr.. r'li.t :+'!¿ìi.! .a-,pa.i. ì" ¡iÕrn:iÍ ¡¿r:i-ì! .i ttrtig'..raseh!èri' ün¡r cti-,'e.aiiiíaice! ci ilcoaa i5 1iÊ', Ina i l;ile i:j.Ã'ecri'ìiiîeriis\r.í ¡y,(14 liic l.r'!:iÉi iaflllrl. :itlr 'ì¡!r!.ie iir,:- i'r'rr: t,i:.lio. CE6iCl6¿01. ¡iieciire 3!1r .;a" 2 . i.t:i2 i: l0l i.l¿.2] ini; rrrc;':L ìi s!tjeôi io nì:.ti riqt.llettcta1. ).a lrS t. gi'l;.ie :! .¡::i:: i'+ ;:a.. r't.i.:e::l ih'r ires:.ij::j JLb]aaì :a l'rÌ?(lr\{, rivcrlal! !ra .,'airic:;aij r: f;:j i iri ..-.,ft4, 'f: mpr)?crralÌ i¡aa':i' Cl'l i:ì:ìt ! :a:!( J;.' :,':e r >1'fr'!.1a,:+' l: -1 : ',"t .'J! ja -ì:l- r?-tc_ :îa _îi .í'a.: :: 'a :. :.:.':-' ^- .i2- ,'.,:.: .- . ::l:l: .i] ¡i: i'":c' rit,r,':0,[ .iiutit':rt.c: xia ]'.a Jt':t. .,rl¡i ierin;. cii inlei a¡irai a: lre rJirí,3.;r Ð:.r !: ::e :1.-i:¿r .1 .ta ai.,ar¿::: !-..,,.,ai.ai tiir:i ìir,, rrìrrai p.!ierì., /iêl ?r irì: 19i¿,i-i:t i'r -1.1.:i a.:t:.0,D. PhÉtpsIolSheetI;r:r!.. i:l),. S. r¡e.rtl).):-È. i¿t:,:1 .) ????Jon \.. 13 úi:,ii!:ìrå :e.C-j.Üar- 6117122,1:38 PM qPublic.net - Garfield County, CO - Property Recsrd Card: R170353 ÐqPublic,net " Garfield County, CO Summary Account Parcef Property Address legal Descriptlon Acres Land SqFt TãxArea MlllLevy Subdivisíon Sale D¡te 5/5t2022 9t3/t997 rl7119æ uu790a 7/UL900 7/1./L9AO 7/U1900 7/U!9W 7/U1900 tlu1900 R1703s3 218104307001 -SgtT SsfconNTY RD NEW CASTLE, CO 81ó47 Sect¡on:4Township: ó Range: 91 Subdivision: RAPIDS ON THE COLORADO LÖt: 1 3,ós 0 L7 62.3270 RAPIDSONTHECOLORADO Yisu-UlÈs Owner MORETTI, LI5AJANE & PODMORE, MICHAEL PO BOX353 NEW CASTLE CO 81ó47 Land Unit Typê 1 AC TO UT 5 AC . O52O (VACANT LANÞ} SquareFeet 0 Astual Values AssessedYear Land Actual lmprovement Actual Total Actua¡ Assessed Values Assessed Year LandÂssessed lmprovement Assessed TotalAssessed Tax History TaxYear Taxes Billed 2A2L $8e7.M 2o.2:¿ $51,170.00 $o.oo $51,170.00 2A22 $14840.00 $0.00 $148¡().C1) 2020 $53û.40 2021 $49,670.00 $o.oo $r,9,670.@ 2027 $14,400,00 $o.oo s14,¿100.00 2019 $sog.t2 20'20 $32,sóO.00 $o.oo $3¿5óO.00 zom se,4q.æ $o.00 $9,¡l4O.0O 2018 $664.24 Sale Prlce $2ú0,000 el içt ¡e rç-to yiqw t!,ìeJla,{- bf oì:Ilg tlqì-loJ tlr is Transfers DeedType SPECIALWARRANWDEED SPECIALWARRANTYDEED Deeds Deeds Deeds Deeds Deeds Deeds Deeds Deeds Reception Number 974427 Book - Page 1032-0945 7032-0967 1032-0948 o996-4665 0834-0233 o4.79-0429 0466-0247 o466-O2V 046ó-OO29 $o $o $o $o $o $o $0 $o $o Property Related Public Documents cl içklere tqJ¡€wft anÊrt-visl4çd-ecþliçÐpsunenl: https://qpublic.schneidercorp.comlApplication.aspx?ApplDE103B&LayerlD=22381&PageTypelÐ=4&PagelD=9447&Q*1790770566&KeyValue=R170353 112 61171?2.,1:38 PM qPublic,net - GarfielrJ County, GO - Property Recod Gard: R170353 Photor No data arallable forthe followlry modules: Buildings, Skekhes. Uqçr_P,!:lvacy Ppliçy QÞPB. P¡iv¿cyNoüce Last D-qta !f plo¿d.: 6/ 17 / 2O22, t:26l.20. AM C)Fçþ¡pJf,çi https:llqpublic.schneidercorp.com/Application.aspx?ApplD=1o38&LayerlD=22381&PageTypelD=4&Pagelp=$/l4/!Q=!/90770566&KeyValue=R170353 212 R 1 7t378 2181043 218104307034 ', R170386' -,!,' ' .*jn :. 40 ,t ü15 R :l -t "t ;""' I ,. f'. : #ÐqPublic"Ílet"'' Garfield County, CO 3347335 COUNry RD NEWCASTLE MORETTI, LISA JANE & PODMO RE, MICHAÊL PO BOX353 NEW CASTLE C O 87647 2019Total Actual Value Overview {i3 Legend Parcels Roads Parcel/Account Numbers Highways , Limited Access Highway Major Road Local Road MinorRoad Other Road Ramp Ferry Pedestria n Way Owner Name Lakes & Rivers - CountyBoundary Line $51,170 Last2Sales Date Price 5/5/2022 $2ó0,CI00 9/3t7997 $O Account Number Parcel Number Acres LandSqFt TaxArea 2019Mil1 Lew R170353 218104307001 Physlcal Address Owner Address 87ór''7 4 o ot7 623214 t ate cr e ated: 6/ !7 12O22 Last Data Uploaded: 6/17 12Q22 3:26:2O ltl,A Deveroped bv{*! Fpþ*eif, çl