HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 726 County Road 137, Glenwood Springs, CO 81601
Parcel No.: 212325300001
Owner Name: Natalie and Tim McDonald Owner Phone: (303) 919‐3434
Designed By: CBO Septic Consulting, Inc. Designer Phone: (970) 309‐5259
Contractor: Trevor Dunston Contractor Phone: (970) 471‐6292
Number of Bedrooms _3__Minimum Tank Capacity _1,000‐gal__Minimum Absorption_630 SF
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐7763________________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 08/26/2022 Expiration Date 08/26/2023
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by CBO
Septic Consulting, Inc. dated August 6, 2022. Changes must be approved by Garfield County Public
Health and the designer prior to construction.
The new Soil Treatment Area (STA) will serve an existing 3‐bedroom residence. The system will
consist of the existing two‐compartment 1,000‐gallon septic tank and include a new inlet tee and an
effluent filter in the outlet tee of the tank. Effluent will gravity flow to a level manifold that will
distribute effluent to 672 ft2 of STA. The new STA will consist of one four‐row gravelless chamber
bed. Each row will consist of 14 Quick4 chambers, for a total of 56 chambers. Inspection ports are to
be installed at each corner of the bed. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
08/26/2022
Issued By: Garfield County Environmental Health
Department
Date