Loading...
HomeMy WebLinkAboutConditions of Permitco NDITIONS OF PERMIT B LRE-08-2 2-77 52 DAN & DONNA MILLER New S/F Dwellin gwl attached garage 21 Tellico Ct., Carbondale Roaring Fork Mesa @ Aspen Glen, Flg 2, Lot 4 1) ALL WORK SHALL COMply W|TH THE 2015 INTERNATIONAL RESIDENTIAL CODE (r.R.c.)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C,) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS", NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTI FICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. 5) OPEN-HOLE SOTLS REPORT REOUTRED AT FOOTING INSPECTION. 2.000 PSF SOIL BEARING CAPACIry. PROVIDE COPY OF ENGINEER'S OBSERVATION REPORT. ó) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGINEERING FOR INSPECTOR AT TIME OF FRAME INSPECTION. 7) ENTIRETY OF STRUCTURE SHALL BE LOCATED INSIDE THE PLATTED BUILDING ENVELOPE. AT FOUNDTION INSPECTION PROVIDE A LOT IMPROVEMENT CERTIFICATE, SEALED BY A COLORADO PROFESSIONAL LICENSED SURVEYOR, VERIFYING THAT THE STRUCTURE - INCLUDING ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WITH GARFIELD COUNry'S BUILDING ENVELOPE REOUIREM ENTS. 8) AN ELEVATION SURVEY, SEALED BY A COLORADO PROFESSIONAL LICENSED SURVEYOR, IS REOUIREDAT FRAME INSPECTION TO VERIFYTHATAS.BUILT ROOF'S COMPLY WITH GARFIELD COUNry'S 2s-FOOT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE.