Loading...
HomeMy WebLinkAboutOpen Hole Soils Report 08.06.2022www.americangeoservices.com sma@americangeoservices.com Ph: (888) 276 4027 Fx: (877) 471 0369 August 06, 2022 PROJECT NO: 0232-D22 CLIENT: Mr. Jonathan Todd Re: Open Hole Inspection Report, 630 Lariat Rd, Silt, CO American GeoServices, LLC (AGS) have performed a geotechnical field inspection/ evaluation at the referenced site. A detailed geotechnical evaluation and geologic hazards assessment of any kind was beyond our scope of services. SUMMARY OF RESULTS Based on the results of our geotechnical field evaluation we made following conclusions and recommendations: •The subgrades are adequately compacted to at least 95% of ASTM D1557 equivalent maximum dry density for the exposed subgrades and/or compacted soils. •The allowable bearing capacity is at least 1,500 psf, for a minimum footing embedment depth of at least 16 inches, provided proper drainage is maintained. •It is important to assure that the bottom of footing is placed at least 16 inches below the final finished and compated subgrade, throughout the design life of the structure. It should be noted that a detailed geotechnical evaluation or detailed geologic hazards evaluation of any kind was beyond our scope of services. It should also be noted that all our recommendations are valid only if proper drainage and stormwater management as per local city, GEOTECHNICAL & MATERIALS ENVIRONMENTAL STRUCTURAL CIVIL ENGINEERING AND SCIENCE 888-276-4027 COLORADO WYOMING OREGON WASHINGTON FLORIDA Page 2 of 2; 0232-D22 county, and state regulations are implemented and maintained throughout the life of the structures. No warranty of any kind is expressed or implied. LIMITATIONS Our Scope of Work for this project did not include any geotechnical evaluation, flood hazard evaluation, civil engineering evaluation, or structural evaluation of any kind, or research, testing, or assessment relative to past or present contamination of the site by any source. If such contamination were present, it is very likely that the exploration and testing conducted for this report would not reveal its existence. If the Owner is concerned about the potential for such contamination, additional studies should be undertaken. We are available to discuss the scope of such studies with you. No tests were performed to detect the existence of mold or other environmental hazards or the presence or absence of collapsible or expansive soils, as it was beyond Scope of Work. Local regulations regarding land or facility use, on and off-site conditions, or other factors may change over time, and additional work may be required with the passage of time. Based on the intended use of the report within one year from the date of report preparation, AGS may recommend additional work and report updates. Non-compliance with any of these requirements by the client or anyone else will release AGS from any liability resulting from the use of this report by any unauthorized party. Client agrees to defend, indemnify, and hold harmless AGS from any claim or liability associated with such unauthorized use or non-compliance. In this report, we have presented judgments based partly on our understanding of the proposed construction and partly on the data we have obtained. This report meets professional standards expected for reports of this type in this area. Our company is not responsible for the conclusions, opinions or recommendations made by others based on the data we have presented. This report has been prepared exclusively for the client, its’ engineers and subcontractors for design and construction of the proposed structure. No other engineer, consultant, or contractor shall be entitled to rely on information, conclusions or recommendations presented in this document without the prior written approval of AGS. We appreciate the opportunity to be of service to you on this project. If we can provide additional assistance or observation and testing services during design and construction phases, please call us at 1 888 276 4027. Sincerely, Sam Adettiwar, MS, PE, GE, P.Eng, M.ASCE Senior Engineer Attachments