Loading...
HomeMy WebLinkAboutObservation of Excavation 10.07.2022amaíl:*nBfiuy**Mfffiigrry 5O2t Counly Kçad 1â4 Glenwood Springa, çç 81ç*i phone: lç79r94ö-7988 lax: {97A)945-8454 kaglanw ood Qkumar usa "tam ww.karya#sa,çç{* {3t{rç* L*caltcrzø: tønver {l4Q}, ?ark*r, Çslaradc Spring*, {*r1 Çç1hne, &1enwa*d Springs, and Summil ççu{12y, Ççlara$ç October 7,2022 Revised October 11, 2022 Edwin Gana 1458 County Road 233 Rille, Colorado 81650 (*&tiyø*rz**{}2{&Wçat2.ççw) Project No.22-7-664 Sabject: Observation of Pad Excavations, Proposed Pole Bam, 1458 County F:oad233, Garfield County, Color¿do DearMr. Qarza: As requesteð, arqresentative of Kumar & Associates observed the pad excavations at the subject site on October 6,2022 to evaluate the soils exposed for foundation support. The {indings of our observations and recornmendations for ths foundation support are presented in this report. The services \ryere performed in accordance with our agreement for professional engineenngservices to you dated September 30, 2022. The proposed 30' by 50' pole barn will be supported by 15 spread footing pads designed for ¿n assumed allou¡able soil bearing pressure of 2,000 psf. At the time of our visit to the site, eleven foundation padexcavations had been cut about 4 feet below the surrounding ground surface. The soils exposed in the bottom of ths excavation consisled of slightly clayey, silty sand with gravel-sizs rock fragments. No free water was encountered in the excavations and the soils were slightly moist to moist. Considering tho conditions exposed in the excavation and the nafure of the proposed constructioa, spread footings place,ð on the undisturbed natural soil designed for an allowable soil bearing pressure of 2,000 psf can be used for support of the proposed pole bam. The exposed soils tend to compress when wetted and there could be some post-construction settlement of the foundation if the bearing soils become wet. f'ootings should be a minimurn width af 16 inches for continuous walls anâ2 feet for calumns. Loose and disturbed soils (and existing fi1l) in footing areas should be removed and the bearing level extended down to the undisfurbed natsral soils. Structural fill placed within floor slab areâs can consist of the on-site soils compacted to at least95Yo of standard Proctor density at a moisture content near optimum. Back{tll placed around the structure should be compacted anóthe surface graded to prsvent ponóing within at least 5 feet of the building. Ths recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evalu¿le the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumplion that soils beneath the footings have equal or better support than those exposed. The risk of foundation movemontmay be greater than indicated in this report because of possible Edwin Gama October 7,2822 Revised October 11, 2022 ?age2 variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface canditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change lhe recommendations contained in this letler. Our services do not include determining tho presenceo prevention or possibility of mold or otherbiological contaminants (MOBC) developing ia the fr¡ture. If the client is concemed about MOBC, then ¿ professional in this special field of practice shosld be consulted. I{youhave any questions or need further assistance, please call our office. Sincerely, Waz*Nz'uø x' &'&*øaz *2ø4æs,hat. ÐanielE. Rev. by: SL? DYþl/1<ac Y"umat &, A, soclat*rs,lw,ø Project No.22-7ô64