HomeMy WebLinkAboutOWTS Design 2789 Riverside Parkway
Grand Junction, Colorado 81501
Phone: 970-255-8005
Info@huddlestonberry.com
October 4, 2022
Project#02196-0007
Wiseland Construction
3677 G 4/10 Road
Palisade, Colorado 81526
Attention: Mr. Parker Moreland
Subject: OWTS Design
515 Stover Valley Road
Glenwood Springs, Colorado
Reference: Geotechnical Investigation, 515 Stover Valley Road, Glenwood Springs,
Colorado by Huddleston-Berry Engineering & Testing, LLC for Parker
Moreland, September 19, 2022.
Dear Mr. Moreland,
At your request, Huddleston-Berry Engineering & Testing, LLC completed design of an Onsite
Wastewater Treatment System (OWTS) for a single-family residence at 515 Stover Valley Road
in Glenwood Springs, Colorado. The site location is shown on Figure 1 – Site Location Map. A
site plan is included as Figure 2.
Site Description
At the time of the investigation, the western portion of the site was occupied by an existing
residence and shop structure. The remainder of the site was open and sloping down towards the
west. Site topography is shown on Figure 2. Vegetation consisted primarily of weeds, grasses,
and brush. The site was bordered to the north and west by rural residential properties and to the
south and east by vacant residential parcels.
Subsurface Investigation
As discussed in the referenced report, the subsurface conditions at the site were fairly consistent.
The test pits encountered 2.0 feet of topsoil above tan, dry to moist, medium dense to dense silty
sand with gravel and cobble soils to the bottoms of the excavations. Groundwater was not
encountered in the subsurface at the time of the investigation.
Although groundwater was not encountered during the subsurface investigation, HBET believes
that the seasonal high groundwater elevation is deeper than 8.0 feet below the existing grade at
this site.
The locations of the test pits are shown on Figure 2. Copies of the test pit logs are included in
Appendix A.
515 Stover Valley Rd.
#02196-0007
10/04/22
Z:\2008 ALL PROJECTS\02196 - Wiseland Construction\02196-0007 515 Stover Valley Road\200 - Geo\02196-0007 LR100422.doc 2
Onsite Wastewater Treatment System
In order to evaluate the site soils for onsite wastewater treatment, percolation testing was
conducted at the site. The percolation rate in the native soils ranged from 4 to 5 minutes-per-
inch. The percolation testing data are included in Appendix C.
In accordance with Garfield County regulations, a percolation rate of between 5 to 60 minutes-
per-inch is required for soils to be deemed suitable for onsite wastewater treatment. Although
the percolation rates were fairly fast, the native soils contain an appreciable quantity of fines and
will provide excellent filtration of effluent. Therefore, based upon the results of the percolation
testing, HBET believes that the native soils are suitable for onsite wastewater treatment.
In addition to the percolation rate of the subsurface materials, the seasonal high groundwater
elevation is an important factor in determining the suitability of the site for Onsite Wastewater
Treatment Systems. For OWTS suitability, the seasonal high groundwater elevation should be at
least four feet below the bottom of the proposed absorption bed. As discussed previously,
groundwater was not encountered at the time of the investigation. In general, based upon the
results of the subsurface investigation, HBET believes that the seasonal high groundwater level
is deeper than 8.0 feet below the existing grade at this site.
Seepage Bed Design
The design of the absorption system generally follows the requirements of the Garfield County
Department of Public Works as outlined in the Garfield County On-Site Wastewater Treatment
System Regulations, effective June 2018. The proposed construction at the site is anticipated to
include a garage containing a bathroom. The proposed bathroom is anticipated to include a water
closet (toilet) and sink.
Based upon the soil percolation rate and visual tactile classification of the soils, a Long-Term
Acceptance Rate (LTAR) of 0.6 will be utilized for the absorption field design. Infiltrator
Systems Quick4 Standard Chambers are proposed. The daily flow of the sewage disposal system
is calculated below, and a plan and profile of the absorption system are shown on Figure 3.
Average Daily Flow = (24.8 GPD/water closet)+(5.8 GPD/sink)
= 31 GPD
Soil Treatment Area = (31 GPD / 0.6) = 51 Square Feet
Adjusted Soil Treatment Area = (51 SF)(1.2)(0.7) = 43 Square Feet
# of Quick4 Chambers = (43 / 12) = 4 Chambers
System Installation
The installation of the septic tank, plumbing lines, Infiltrators, etc. should be completed in
accordance with the Garfield County On-Site Wastewater Treatment System Regulations and
Infiltrator Systems, Inc. specifications. In addition, the following construction procedures are
recommended:
515 Stover Valley Rd.
#02196-0007
10/04/22
Z:\2008 ALL PROJECTS\02196 - Wiseland Construction\02196-0007 515 Stover Valley Road\200 - Geo\02196-0007 LR100422.doc 3
The septic tank and distribution box should be placed level over native soils that have
been scarified to a depth of 8 to 12 inches, moisture conditioned, and recompacted to
a minimum of 95% of the standard Proctor maximum dry density, within ±2% of
optimum moisture content. However, up to 3-inches of washed rock or pipe bedding
passing the 1-inch sieve may be used as a leveling course under the septic tank and/or
distribution box.
The bottoms of trenches and backfill around the septic tank and distribution box
which will support sewer or effluent lines should be compacted to at least 90 percent
of the standard Proctor maximum dry density, within ±2% of optimum moisture
content. Pipe bedding should have a maximum particle size of 1-inch.
Vehicular or heavy equipment traffic and placement of structures should not encroach
within 10 feet of the septic tank or distribution box.
Inspection Schedule
Huddleston-Berry Engineering & Testing LLC should be retained to monitor the construction of
the OWTS. The following schedule of observation and/or testing should be followed:
Observe the absorption bed excavation prior to placement of Infiltrator chambers.
Observe placement of the septic tank, distribution box, and all connecting sewer and
effluent lines prior to backfill. Verify proper fall between inverts.
Observe and verify installation of the absorption bed prior to placement of cover and
backfill.
In conformance with Garfield County regulations, HBET will be required to provide the Garfield
County Health Department with documentation certifying that the OWTS was placed in
conformance to the plan and profile and Garfield County regulations.
General Notes
The OWTS design was based upon the results of the subsurface investigation and on our local
experience. The design is valid only for the proposed construction.
We are pleased to be of service to your project. Please contact us if you have any questions or
comments regarding the contents of this report.
Respectfully Submitted:
Huddleston-Berry Engineering and Testing, LLC
Michael A. Berry, P.E.
Vice President of Engineering
10/04/22
FIGURES
Garfield County, CO
Developed by
Date created: 8/18/2022
Last Data Uploaded: 8/18/2022 5:53:17 AM
6,406 ft
7562
7564
7566
7560
7558
7556
7554
2789 Riverside Parkway
Grand Junction, CO 81501
Project No.: 02196-0007
Date: 10/04/22
By: MAB
515 STOVER VALLEY ROAD
PARCEL#218735100010
FIGURE 2 - SITE PLANTEST PIT
C.I. = 2 FT
SCALE: 1" = 200'
**NOTE: TANK AND BED LOCATIONS APPROXIMATE AND MAY SHIFT SOME DURING
CONSTRUCTION BASED UPON SITE TOPOGRAPHY, OWNER PREFERENCE, AND/OR OTHER
FACTORS AS LONG AS APPLICABLE SETBACKS ARE MET. ACTUAL LOCATION OF TANK AND
BED WILL BE INDICATED ON AS-BUILT DRAWINGS.**
SITE PLAN
ENLARGED VIEW
~50'
~90'
(10' MIN)
~278'
~125'~150'
~30'
~80'
~375'
~475'~435'
~40'
~33'
~265'
(100' MIN)
TP-1
TP-2
7568
16'
~41'~34'
5' MIN
~78'
~32'
3'
TP-1
TP-2
C.I. = 2 FT
SCALE: 1" = 30'
REPAIR AREA
STA
EXISTING
GARAGE
MINIMUM 1,000
GALLON TANK
WATER LINE
EXISTING HOME
EXISTING
GARAGE
EXISTING STA
NEW STA EXISTING SEPTIC TANK
WATER LINES
WELL
DRIVEWAY
10/04/22
2789 Riverside Parkway
Grand Junction, CO 81501
Project No.: 02196-0007
Date: 10/04/22
By: MAB
MINIMUM SETBACKS
(UNITS = FT)
**OTHER SETBACKS NOT LISTED HERE SHOULD BE IN ACCORDANCE WITH GARFIELD COUNTY OWTS REGULATIONS
**USE SWEEP 90'S OR
TWO 45'S AT 90
DEGREE BENDS**
DETAIL AREA
SCALE: 1" = 20'
515 STOVER VALLEY ROAD
PARCEL#218735100010
FIGURE 3 - SEPTIC SYSTEM
DETAILS
5' MIN
20' MIN
SEPTIC TANK WITH
MINIMUM 1,000
GALLON CAPACITY
INFILTRATOR SYSTEMS QUICK4
STANDARD CHAMBERS
EXISTING
GARAGE
4-INCH DIAMETER SEWER AND
EFFLUENT PIPE MEETING ASTM D1785,
SCHEDULE 40 OR SDR 35
WATER LINE
16'
3'
INSPECTION PORT
GENERALIZED SYSTEM PROFILE
GENERALIZED BED PROFILE
COVER SOIL; NATIVE SOILS OR OTHER SUITABLE
TOPSOIL. GRADE TO CARRY SURFACE WATER
AWAY FROM BED.
NONWOVEN, NEEDLE PUNCHED, GEOTEXTILE
FABRIC IMMEDIATELY ABOVE CHAMBERS
INFILTRATOR SYSTEMS QUICK4
STANDARD CHAMBERS
INSPECTION PORT
10/04/22
APPENDIX A
Typed Test Pit Logs
Silty Sand with Cobbles and Organics (TOPSOIL)
Silty SAND with Gravels and Cobbles (SM), tan, dry to moist,
medium stiff to stiff
GB-1: Lab Classified
Bottom of test pit at 8.0 feet.
GB
1 455413299
NOTES
GROUND ELEVATION
LOGGED BY TC
EXCAVATION METHOD Trackh/Backhoe AT TIME OF EXCAVATION Dry
AT END OF EXCAVATION Dry
AFTER EXCAVATION ---
TEST PIT SIZE
EXCAVATION CONTRACTOR Client GROUND WATER LEVELS:
CHECKED BY MAB
DATE STARTED 8/19/22 COMPLETED 8/19/22
DEPTH(ft)0.0
2.5
5.0
7.5 GRAPHICLOGATTERBERG
LIMITS
MATERIAL DESCRIPTION
SAMPLE TYPENUMBERFINES CONTENT(%)RECOVERY %(RQD)BLOWCOUNTS(N VALUE)POCKET PEN.(tsf)DRY UNIT WT.(pcf)MOISTURECONTENT (%)LIQUIDLIMITPLASTICLIMITPLASTICITYINDEXPLASTICITYINDEXPAGE 1 OF 1
TEST PIT NUMBER TP-1
CLIENT Wiseland Construction
PROJECT NUMBER 02196-0007
PROJECT NAME 515 Stover Valley Road
PROJECT LOCATION Glenwood Springs, CO
GEOTECH BH COLUMNS 02196-0007 515 STOVER VALLEY ROAD.GPJ GINT US LAB.GDT 9/15/22Huddleston-Berry Engineering & Testing, LLC
2789 Riverside Parkway
Grand Junction, CO 81501
970-255-8005
Silty Sand with Cobbles and Organics (TOPSOIL)
Silty SAND with Gravels and Cobbles (sm), tan, dry to moist,
medium dense to dense
Bottom of test pit at 8.0 feet.
NOTES
GROUND ELEVATION
LOGGED BY TC
EXCAVATION METHOD Trackh/Backhoe AT TIME OF EXCAVATION Dry
AT END OF EXCAVATION Dry
AFTER EXCAVATION ---
TEST PIT SIZE
EXCAVATION CONTRACTOR Client GROUND WATER LEVELS:
CHECKED BY MAB
DATE STARTED 8/19/22 COMPLETED 8/19/22
DEPTH(ft)0.0
2.5
5.0
7.5 GRAPHICLOGATTERBERG
LIMITS
MATERIAL DESCRIPTION
SAMPLE TYPENUMBERFINES CONTENT(%)RECOVERY %(RQD)BLOWCOUNTS(N VALUE)POCKET PEN.(tsf)DRY UNIT WT.(pcf)MOISTURECONTENT (%)LIQUIDLIMITPLASTICLIMITPLASTICITYINDEXPLASTICITYINDEXPAGE 1 OF 1
TEST PIT NUMBER TP-2
CLIENT Wiseland Construction
PROJECT NUMBER 02196-0007
PROJECT NAME 515 Stover Valley Road
PROJECT LOCATION Glenwood Springs, CO
GEOTECH BH COLUMNS 02196-0007 515 STOVER VALLEY ROAD.GPJ GINT US LAB.GDT 9/15/22Huddleston-Berry Engineering & Testing, LLC
2789 Riverside Parkway
Grand Junction, CO 81501
970-255-8005
APPENDIX B
Percolation Testing Results
Project Name:
SOIL PROFILE
(ft) (ft) (ft)
(in) (in) (in)
(in) (in) (in)
(min.) (in.) (in.) (min.) (in.) (in.) (min.) (in.) (in.)
Rate (min/in): Rate (min/in): Rate (min/in):
Average Percolation Rate (min/in):
515 Stover Valley Rd. City:Glenwood Springs Date: 8/19/2022
Testing Conducted By: T. Collins
PERCOLATION TESTING
STP322
Project No. 02196-0007
Test Pit No. TP-2
State Colorado
Supervising Engineer: M. Berry
TEST PIT DIMENSIONS
Length
(ft)
Width
(ft)
Depth
(ft)
Water Level Depth (ft)
Depth (ft) Not Encountered
Remarks
0-2 Silty Sand with Cobbles and Organics (TOPSOIL)
2-8
Silty SAND with Gravels and Cobbles (sm), tan, dry to moist, medium
dense to dense
8.0 X
Depth
(ft)Description
Top of Hole Depth: 2 Top of Hole Depth: 4 Top of Hole Depth:
Test Number: 1 Test Number: 1 Test Number:
Depth of Hole: 13 Depth of Hole: 12 Depth of Hole:
Diameter of Hole: 4 Diameter of Hole: 4 Diameter of Hole:
Time Water
Depth Change
02 02.25
Time Water
Depth Change Time
Water
Depth Change
10 8.25 6.25 10 7.75 5.5
20 12.25 4 20 12 4.25
40 0.75 40 0.75
30 Dry 30 Dry
50 2.75 2 50 3.25 2.5
60 4.5 1.75 60 4.75 1.5
80 11.25 5.5 80 Dry
70 5.75 1.25 70 11 6.25
90 Dry 90 0.5
100 0.625 100 2.75 2.25
120 4.625 1.75 120 8.25 2.25
110 2.875 2.25 110 6 3.25
54
5