HomeMy WebLinkAboutHigh Strength Bolt Inspection ReportsWest Slope Testing & Inspection LLC
Phone: 970-434-6988
Cell: 970-260-2844
Report #1
Page 1 of 1
Inspection Report
Dates: 12-31-22 &. l-4-22
Project: Lot 17 Aspen Glen
Address: 109 W. Diamond A Ranch Rd. Aspen Glen/Carbondale, CO
Building Permit No: BLRE-05-2 I -6867
General Contractor: Bella Villa Builders
Contractor that Performed Work: West Elk Supply
Inspection of shop fabrication or field work at.iob site: Shop
Report: Visually inspected welding at the steel plates & re-bar dowels for two
embed plate assemblies on the project.
The welding inspected above appeared to be in general conformance with the
shop plans & the quality requirements of the AWS Structural Welding Codes.
InspectorlTechnician: Douglas E Yo r02
I
Ste*N ¡S lnspector
Spray-applie<l Fireproofrng lnspeetor
Douglas E younq
cn4 96070131 -
Qû1 EXP.7nna23
West Slope Testing & Inspection LLC
3177 Glendam Dr.
Grand Junction, CO 81504
Phone: 970-434-6988
Cell: 970-260-2844
Inspection Report
Report #2
Page I of 1
Date: 2-21-22
Project: Lot 17 Aspen Glen
Address: 109 W. Diamond A Ranch Rd. Aspen Glen/Carbondale, CO
Building Permit No: BLRE-05-2 I-6967
General Contractor: Bella Villa Builders
Contractor that Performed Work: West Elk Supply
Inspection of shop fabrication or field work at job site: Shop
Report: Visually inspected shop welding at the steel beams & columns piece
marked CI, C2, C3, C4, C5, C6, 81, 82, 83, and 84.
The welding inspected above appeared to be in substantial confonnance with the
shop plans, and the quality requirements of the AWS Dl.l Structural Welding
Code.
Steel materials were also verified to have identification markings, as per AISC &
ASTM standards. Welder qualifications & welding procedures were verified on
previous inspections at this fabricator.
Inspector/Technician: Douglas E
@ Douglas E youno
cw 9607013r -
QCI EXP.7t1t2o2g
'West Slope Testing & Inspection LLC
3177 Glendam Dr.
Grand Junction, CO I1504
Phone: 97A-ß4-6988
Cell: 970-260-2844
Report #3
Page 1 of I
Inspection Re port
Date: 6-20-22
Project: Lot 17 Aspen Glen
Address: 109 W. Diamond A Ranch Rd. Aspen Glen/Carbondale, CO
Building Permit No: BLRE-05-2 l -6967
General Contractor: Bella Villa Builders
Contractor that Performed Work: West Elk Supply
Inspection of shop fabrication or ÍTeld work at .iob site: Field
Report: Visually inspected field welding & high strength A325 bolting at the
column cap to beam connections, steel column bases to shim packs & shim packs
to tops of steel beams, and field welded beam web stiffeners.
The onsite welding & high strength 4325 bolting inspected, as noted above
appeared to be in general conformance with the plans, and the quality
requirements of the AV/S Dl.1 Structural Welding Code & the AISCIRCSC
Specification for high strength bolting.
E. Young
Inspector/Technician: Douglas E Young
Steel &Inspector
Spray*pplied Inspector
Douglas E Young
cwt 96070131
QCl EXP.7t1t2023