Loading...
HomeMy WebLinkAboutPermit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 1452 CR 259 Rifle, CO Parcel No.: 212734200303 Owner Name: Jose Mendoza Owner Phone: (970) 710-1549 Inspected By: Boundaries Unlimited, Inc. Designer Phone: (970) 945-5252 Number of Bedrooms: _4_ Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 613 SF OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-7837_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _11/1/2021____________________ Expiration Date_11/1/2022_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by Boundaries Unlimited, Inc. dated August 28, 2022. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The owner is proposing to add a new bedroom in an existing 3-bedroom residence to an existing OWTS that was constructed under permit Number SEPT-01-15-3516. The existing OWTS was designed to accommodate 3-bedrooms. The system will consist of an existing, two-compartment 1,250-gallon septic tank set level with access to grade. Effluent will gravity flow to 613 ft2 of STA. The altered STA will consist of three existing gravelless chamber trenches, with two new trench extensions consisting of 5 additional chambers and the third extension consisting of 6 new chambers (16 chambers total). Inspection ports are to be installed at the end of each trench extension. Maintain all setbacks and elevations as designed. In order to accommodate the additional bedroom, alteration to the existing STA is necessary. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 11/1/2022 Issued By: Garfield County Environmental Health Department Date