Loading...
HomeMy WebLinkAboutPlansJOINS PANEL 1453 r Zo JOINS PANEL 1855 KEY TO MAP 500-Year Flood Boundary 100-Year Flood Boundary Zone Designations 100-Year Flood Boundary 500-Year Flood Boundary Base Flood Elevation Line 513 With Elevation In Feet** Base Flood Elevation in Feet (EL 987) Where Uniform Within Zone** Elevation Reference Mark RM7x Zone D Boundary - River Mile • M 1.5 **Referenced to the National Geodetic Vertical Datum of 1929 EXPLANATION OF ZONE DESIGNATIONS ZONE EXPLANATION A Areas of 100-year flood; base flood elevations and flood hazard factors not determined. AO Special Flood Hazard Areas inundated by types of 100-year shallow flooding where depths are between 1.0 and 3.0 feet; depths are shown, or areas of 100- year alluvial fan flooding,. depths and velocities shown, but no flood hazard factors are determined. AH Areas of 100-year shallow flooding where depths are between one (1) and three (3) feet; base flood elevations are shown, but no flood hazard factors are determined. Al-A30 Areas of 100-year Flood; base flood elevations and flood hazard factors determined. A99 Areas of 100-year flood to be protected by flood protection system .under construction; base flood elevations and flood hazard factors not determined. B Areas between limits of the 100-year flood and 500- year flood; or certain areas subject to 100-year flood- ing with average depths less than one (1) foot or where the contributing drainage area Is less than one square mile; or areas protected by levees from the base flood. (Medium shading) C Areas of minimal flooding. (No shading) D Areas of undetermined, but possible, flood hazards. V Areas of 100-year coastal flood with velocity (wave action); base flood elevations and flood hazard factors not determined. V1-V30 Areas of 100-year coastal flood with velocity (wave action); base flood elevations and flood hazard factors determined. NOTES TO USER Certain areas not in the special flood hazard areas (zones A and V) may be protecteu by flood control structures. This map is for flood Insurance purposes only; it does not neces. sarily show all areas subject to flooding In the community or all planimetrlc features outside special flood hazard areas. For adjoining map panels, see separately printed Index To Map Panels. INITIAL IDENTIFICATION: DECEMBER 15, 1977 FLOOD HAZARD BOUNDARY MAP REVISIONS: FLOOD INSURANCE RATE MAP EFFECTIVE: DECEMBER 15. 1977 FLOOD INSURANCE RATE MAP REVISIONS: Map revised January 3, 1986 to change flood plain boundaries, zone designations, base flood elevations, corporate limits, scale, cultural features, or map format. To determine if flood insurance is available in this community, contact your insurance agent, or call the National Flood Insurance Program, at (800) 638-6620. APPROXIMATE SCALE IN FEET 1000 O 1000 NATIONAL FLOOD INSURANCE PROGRAM FIRM FLOOD INSURANCE RATE MAP GARFIELD COUNTY, COLORADO (UNINCORPORATED AREAS) I III III II (SEE MAP INDEX FOR PANELS PANEL 1465 OF 1900DT PRINTED) COMMUNITY -PANEL NUMBER 080205 1465 B MAP REVISED: JAN UARY 3, 1986 z yy.y Federal Emergency Management Agency I 34" TYP INFILTRATOR QUICK4 STANDARD CHAMBER BED NOT To SCALE BACKFILL MATERIAL — NATIVE, OR ESTABLISH VEGETATIVE COVER — FILL PER DESIGN SPECIFICATIONS ail yx 1 �J TYPICAL CROSS SEC7712N HIGH CAPACITY H-20 INFILTRATOR CHAMBER SYSTEM NOT TO SCALE *MEETS ASTM C-1227 SPEC INCLUDING C-1664-06 FOR RESILIENT CONNECTORS • 4000 PSI CONCRETE • CAN BE DELIVERED COMPLETE WITH INTERNAL PIPING • PVC, POLY OR CONCRETE RISERS AVAILABLE • PUMP OR PUMP / SCREEN KIT I 500 GALLON STANDARD: BUTYL RUBBER SEALANT E" WEEP HOLE PUMP OR PUMP/SCREEN KIT H PER DESIGN DIGGING SPECS INVERT DIMENSIONS NET CAPACITY NET WEIGHT LID TANK TOTAL 7' L X 7' W 56" BELOW INLET INLET 56" OUTLET 73" LENGTH 58" WIDTH 58" HEIGHT 92" 522 GAL 1,340 LEIS 4,100 LBS 5,64OLB 500 GALLON PUMP VAULT NOT TO SCALE DESIGN NOTES • Design per performance test per ASTM C1227 • Top surface area 62.33 ft' • Vc @ 28 days; concrete = 6,000 PSI Min. Installation: • Tank to be set on 5" min. sand bed or pea gravel • Tank to be backfilled uniformly on all sides in lifts less than 24" and mechanically compacted • Excavated material may be used for backfill, provided large stones are removed • Excavation should be dewatered and tank filled with water prior to being put in service for installation with water table less than 2' below grade • Meets C1644-06 for resilient connectors • Inlet and Outlet identified above pipe • Delivered complete with internal piping • 4' Maximum bury depth Flexibl Boc ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 0' — 0" 3' — 0" 1' 0" 3'-0" 2' - 0" 4' - 0" 3' 0" 4' -0" DRY 4' - 0" 20" Clear Ac r rTANKI IDS er int Section View Digging Specs Invert Dimensions Net Capacity Net Weight 13' Long x 8' Wide 56" below inlet Inlet Outlet Length Width Height Inlet Side Outlet Total I Lid I Tank I Total 56" 53" 132" 68" 68" 1002 gal 507 gal 1509 gal 3600 Ibs 11180 Ibs 14780 Ibs 1500 GALLON SEPTIC TANK NOT TO SCALE LOCATE DRAIN CLEANOUTS AT ALL DIRECTION CHANGES GREATER THAN 45' IN THE HORIZONTAL AND VERTICAL STEPS MAXIMUM HORIZONTAL RUN BETWEEN CLEANOUTS TO BE 100 FEET. FINISHED SURFACE PLUG 45' PVC C ELBOW 410 PERFORATED y4y5* PVC OR V,P� PIPE ELBOW FLOW — — FLOW CLEAN —OUT DETAIL NTS COORD. w/ MEP FOR PLUMBING IF INTERNAL CLEANOUT SUF77CES JUST PRIOR TO LEAKING STRUCTURE USE FOR CLEANOUTS OR DOWNSPOUT CONNETIONS UNPAVED AREAS PAVED AREAS MATCH EXISTING AC PVMT. SAW CUT ASPHALT ONLY Jt- NO OTHER TYPE CUT UNCLASS. FILL v >> L MATCH EXISTING LEVELING COURSE, COMPACTED TO 90% v COMPACT TO 95% MAX. DRY DENSITY MAX.DRY DENSITY MATCH EXISTING SUB —BASE U0 0C, SLOPE PER OSHA REQUIREMENTS NON —FROST SUSCEPTIBLE FILL COMPACT PER GEOTRCH REC. BURIED PIPE TRENCH WIDTH r BEDDING MATERIAL COMPACT PIPE DIA +9" SAND OR CLASS 6 ABC MIN. 4" ABOVE AND BELOW PIPE NOTES: 1. PLACE AND COMPACT BEDDING MATERIAL BEFORE INSTALLING PIPE. 2. PIPE BEDDING MUST BE IN PLACE, COMPACTED AND PIPE INSTALLED AT TIME OF CONC INSTALLATION OBSERVATION 3. 12" OR LARGER PIPE, USE CDOT STANDARD DETAILS. DRAINAGE & SMALL PIPE TRENCH DETAIL USE FOR SINGLE CONDUITS WHERE NOT OTHERWISE SPECIFIED BY UTILITY PROVIDER AND SEPTIC SYSTEM PUMP DISCHARGE PIPE 6" SCH 80 PVC BEND 1O'X 6" SCH 80 PVC REDUCING COUPLING FROM WA TANK 8160.0 4 1/2" NST FITTING W/ CAP (STANDARD PUMPER NOZZLE) d I FINISH GRADE 0 DRY HYDRANT N. T.S. 1 1/2" COPPER WATER SERWIC£ FROM EXIST ON—MYN. WATER LINE GRADE 10" SCH 80 PVC BEND MANWAY DETAILS PROVIDED BY o MANUFACTURER 41 8f53.0 O - O � I I 8142.67 3" DIP SUPPLY TO PUMPHOUSE AND ON—MTN BACK DRAIN LINE 1 1/2" FL4RE/MALE ADAPTOR 2" X 1 1/2" REDUCER TANK WALL (TYP.) TANK LAYUP (7YP.) ­-4 — - " CONCRETE PAD " DIA. MANWAY ?ER �SEE DETAIL ABOVE LV 4" FLANGED CONNECDON TO TANK —4" x J" DIP FL x MJ REDUCER -3" DIP MJ 90' MALE ADAPTOR —2" PVC 90' b PEA GRAVEL OR CRUSHED STONE (TYP.) 2" PVC DRAIN LINE W/2" VALVE TO DAYLIGHT NOTES: 1. THE CONTRACTOR SHALL PROVIDE FIBERGLASS REINFORCED PLASTIC (FRP) U.L. LABELED UNDERGROUND STORAGE TANK AS SHOWN ON THE DRAWING. SIZES AND FITTINGS SHALL BE AS SHOWN. THE TANKS SHALL BE "CENTURY CAST" TANKS AS MANUFACTURED BY XERXES CORPORATION AND AVAILABLE THROUGH DODSON ENGINEERED PRODUCTS, OR EQUAL. 2. TANKS SHALL BE TESTED AND INSTALLED WITH PEA GRAVEL OR CRUSHED STONE AS SPECIFIED IN THE CURRENT INSTALLATION INSTRUCTIONS PROVIDED WITH THE TANK. (PUBLICATION CF-123) 3. MANWAY MUST NOT REST UPON THE TANK. MANWAY TO BE SUPPORTED BY CONCRETE PAD. MANWAY TO BE LOCATED 41 1/4" FROM CENTER OF TANK TO THE CENTER OF MANWAY. 10.000 GALLON TANK DETAIL N.T.S. o� CV (0 a) 00 �® U)U E ss� (n o vJ iT) L 0 � U 0 X � c U)0'i . O On O T: to ' > C ?� U) U J "U c: E C E 0 U U Cn 0 N i J *1_I7I I I I I I I I l a Job No. 2022.3567 Drawn by: 7 Print Date: QC: XX I PE: 7 File: UCS•Deta OWTS Details Dwg No. C10 X ub-basin (Basing Area DETENTION \ sgft cuft l EXISTING DETENTION DITCH 1824 CUFT OF STORAGE OVERFLOW LOCATION FOR VOLUMES GREATER THAN 25-YEAR DETENTION , 1 __-__ I t \ - ; --- - :�- _ - ---- _ APPROX RIDGELINE- 7------- NO SURFACE CHANGES `* \ NORTH OF THIS LINE ------------- , IRRIGATION AND DRAINAGE CULVERT/DITCH - NO CHANGE ------------ ,. _ ` ^ \\,•\ `, \ ',\ 1, : , - , , j • - / , • �� - . , \' n , , - --- , y 62 3Y 1uft ------------- ``,�j � , ,�'.,, ',, ,,\.,\ `. �: w �� / C•`; f i , � '.Ja I�-'•. w � iris! t }, , •' . , � . � \ ,\ }\', �\ / \ s i i \., t r :`� it v / r , : y \; \. y : , y j/ •`�� Yf_.l- K�77'—_—��- _ - ___ � _ __. `>Q,-- j' fir%- — p ti . ___ _ -•------------ - ___ - --__•_ _ _ < _ _ _ __ _ _ - - --- -- - -� r' _ - - - - - <- - -- r - - - i� _-_----'Z ( CORYELL ROAD DRAINAGE REMAINS IN ROW --------------- / , Graphic Scale 0 10 20 40 In Feet: 1" = 20' O O O N 00 (D 00 �0 0 ou) O 0 Cn • i O U X_ (n O C O U) O LO C: V V VI v � J • L a) O E W \V Cn O Z 0 F- U F z Z 0 U 0 w O Z z J w 0 a. C 0 N N 0 a` Job No Drainage Basin Map No. Dwg DA-MAP Of'. 1 ■ a a y ` k \ r' , S1, O, f ; i S\ r ;' �� �� � .ill , l l 1 l l l l•, �, \ \.�' ,,, ,� i` I �`' l l. l l l. l l l l l l: l l l l ,'l - -• rN: 1G � �� h' l :1 i l . l l 1 . l l l � l l l' l =l. h; :- - •`~. �'r:,;\���''•, °� \ �� ll1 111 lllllll.l l" -- y \r -- .- EX OH POWER l u l l I l :1 l 1 l \ TO REMAIN . i qq. r ¢ 59 k r / 60' - , 1/ < , \ Coi - -ter �\ \ �pq _ --- - / f ORENCO OR APPROVED F ` EQUAL AUTOMATIC �<Q DISTRIBUTION VALVE N1602726.50 MODEL 44 3 E2499287.07 STA CORNER E' N 1602721.91 s'� . f' /, / a / 1� •,� \ `. q\\�E2499282.51 CP ADV If E.- / T e `� 4 TRANSPORT LINES lS. / "i`.iF �� q ` 1-1/2'0 SOLID WALL \ _ SCHEDULE 40 PVC PIPE Y \` Iro sdo ` �; N7602715.6363 Y • \ p� \ \ •, E2499281.98 STA CORNER Y\ N1602668.30 to E2499211.35 SEPTIC TANK �k 16026 .56 �..\ E2499221.55 ` - ------ -- S f SEPTIC TANK ` INSTALL CLEANOUT WITHIN Sg \PAY, w' _ 5.0' OF STRUCTURE. SEE SHEET C10r / \F q 5950- �, �, 9 ' o' 8 \ \ \ £\ TRANSPORT LINE \ <pq PROPOSED BUILDING - �1-1/2"0 SOLID WALL FF 5 - _ -- SCHEDULE PE 960.52 DULE 40 PVC PI l / / CONC PROP 1,500 GALLON SEPTIC TANK; TWO COMPARTMENTS \\ AND W/HIGH HEAD PUMP` j / wa4 vm---_ ._____va4_ VaT Ve4 aa4 rvanvas vm- 5955- - `: = : -- - _ = - k _ _ - - - - -_ --- __- - - - ---- ---- - ----- -max -- __- -- --------- - - ------ ---- -- - -- r=ice aFfi - 5945 _- -:594 , i^ .. ___ __ _ .- - -.-_ �- .____ � - _T __-='tT,•---a,P,_ �v-r .,r--�--Gfr�--_^^---7��.-z"�_-+' c�?="C j..:r .ems-.oEfi-=-��`��__- O �•- GQ� Coryell `' Road X s- r s-+':`----i _'`�ri ry - CAN_ _ �CATV_- C'AA� ___ CCAw r /`�• z I / 5940-- �•' _ / �� , 31TE W ATER T NT GENER THIS SHEET IS PART OF A CIVIL ENGINEERING DESIGN COMPRISED OF 11 SHEETS, WITH ACCOMPANYING REPORTS AND SUPPORTING INFORMATION. THE INSTALLER SHALL REVIEW THESE DbCUMENTS AND BECOME FAMILIAR WITH THEM PRIOR TO THE CONSTRUCTION OF THIS ON -SITE WASTEWATER TREATMENT SYSTEM (OWTS). THE INSTALLER SHALL BE APPROVED BY GARFIELD COUNTY AND SHALL CONFORM TO ALL COUNTY REGULATIONS. ALL COMPONENTS OF THE OWTS SHALL MEET APPLICABLE REGULATIONS, THE INSTALLER SHALL NOTIFY GARFIELD COUNTY ENVIRONMENTAL HEALTH AND THE CIVIL ENGINEER AT LEAST THREE DAYS IN ADVANCE OF THE OWTS INSTALLATION SO THAT THE REQUIRED INSTALLATION OBSERVATIONS CAN BE MADE OF THE SEPTIC TANK, SOIL TREATMENT AREA, AND RELATED COMPONENTS BEFORE BACKFILLING. THE SEPTIC TANK AND SOIL TREATMENT AREA INSTALLATIONS SHALL BE SUBSTANTIALLY COMPLETE AND READY TO BE BACKFILLED PRIOR TO REQUESTING AN OBSERVATION. THE OWTS SHALL BE INSTALLED IN ACCORDANCE WITH SGM PLANS, DETAILS AND SPECIFICATIONS, AND MANUFACTURERS' RECOMMENDATIONS. SUBSTITUTIONS OF COMPONENTS OR MATERIALS WILL NOT BE ALLOWED WITHOUT THE WRITTEN APPROVAL OF THE CIVIL ENGINEER. INSTALLER SHALL PROVIDE CATALOG CUT WHEN REQUESTING SUBSTITUTIONS. ALL ELEVATIONS GIVEN ARE RELATIVE TO NAVD88. THE INSTALLER SHALL DETERMINE ALL ELEVATIONS AND DIMENSIONS AT CRITICAL TIE-IN POINTS IN THE FIELD. QUESTIONS ON VERIFICTION OF CRITICAL ELEVATIONS SHALL BE DIRECTED TO THE ENGINEER. THE SOIL TREATMENT AREA (STA) SHALL BE PROTECTED FROM COMPACTION. VEHICULAR TRAFFIC SHA LL BE KEPT OFF OF THE STA AND VEHICLES SHALL NOT BE PARKED ON THE STA. DUMP TRUCKS AND HEAVY TIRED VEHICLES SHALL NOT BE ALLOWED ON THE SOIL TREATMENT AREA. ALL SOIL RUTTED OR COMPACTED SHALL BE REMOVED AND REPLACED WITH SAND. ALL PVC PIPE CONNECTIONS SHALL BE SOLVENT WELDED, UNLESS OTHERWISE SPECIFIED. ALL RISERS, VALVE BOXES, AND HAND HOLES SHALL EXTEND 2 INCHES ABOVE SURROUNDING FINISHED GRADE. SOIL SHALL BE BUILT UP AROUND RISERS AND SLOPED AWAY FROM RISERS AT A 2% MIN. SLOPE; SLOPE TO DAYLIGHT. SEWER PIPE AND EFFLUENT PIPE SHALL BE PROPERLY BEDDED PER THE TRENCH DETAIL PROVIDED ON SHEET C10. REVEGETATION OF ALL AREAS DISTURBED FOR OWTS CONSTRUCTION SHALL BE SEEDED PER COUNTY REGULATIONS. SEEDING SHALL BE THE RESPONSIBILITY OF / THE OWNER AND CONTRACTOR. 12. SEPTIC TANK ASSEMBLIES SHALL BE CONSTRUCTED WATER TIGHT TO ASSURE NO GROUND OR STORM WATER WILL EFFECT DESIGN VOLUMES OF THE ASSEMBLIES. 13. INSTALLER TO PROVIDE CLEANOUTS AT THE BUILDING AND UPSLOPE OF TWO OR MORE BENDS CLOSER THAN 10' PER THE DETAIL ON SHEET C10. / /''•, \ 14. ALL 90' BENDS SHALL BE CONSTRUCTED FROM TWO 45' ELBOWS. '\ 15. DESIGN AND LOCATION OF SITE IRRIGATION BY OTHERS. THE STA SHALL NOT BE IRRIGATED. \\ \ 16. AIR/VACUUM RELIEF VALVES SHALL BE PROVIDED AT ANY LOCATION WHERE THE Tv, VERTICAL PROFILE OF THE SEWER LINE CHANGES ABRUPTLY. r 17. LOCAL BENCH MARK FOR STA TO BE DETERMINED IN THE FIELD. \ ` SOIL TREATMENT BED AREA (STA); 480 EFFLUENT PUMPING SYSTEM: FT2; 4 COLUMS, 2 CONTAIN 9 1. THE PUMPING SYSTEM SHALL HAVE A COLD WEATHER DISCHARGE ASSEMBLY. A 1 10 INFILTRATORS; 38 CHAMBERS TOTAL. / `INFILTRATORS, WHILE THE OTHER 2 HAVE 4'0 DRAIN HOLE IN THE COLD WEATHER DISCHARGE ASSEMBLY SHALL DRAIN 1-1/2"0 SCHEDULE 40 PVC PIPE BACK INTO SEPTIC TANK, W/ORIFICES. SEE DISTRIBUTION LATERAL NOTES, SHEET C10. \ 2. THE DISCHARGE ASSEMBLY SHALL HAVE A DISCONNECT UNION ACCESSIBLE FROM \ GROUND LEVEL FOR PUMP REPLACEMENT. y f 1 \\ ;, y;' 3. THE PUMP SYSTEM SHALL INCLUDE THREE FLOAT SWITCHES; AN "ON" FLOAT, AN "OFF" FLOAT, AND A HIGH WATER ALARM. AN ADDITIONAL LOW WATER ALARM/REDUNDANT OFF FLOAT IS OPTIONAL. SEE THIS SHEET FOR SETTINGS. 4. FLOAT TREE HANDLE AN 01 D FILTER HANDLE SHALL EXTEND TO A MAX. DEPTH OF 12 INCHES BELOW THE TOP OF THE TANK RISER. N1602709.54 y E2499323.29 �r 5. INSTALLER SHALL FURNISH AND INSTALL EXTERNAL SPLICE BOXES. STA CORNER 7 `'OO • `- ;�� `-.� '•. ~` --\- 6. SPLICE BOXES SHALL BE UL APPROVED FOR WET LOCATIONS, SHALL BE LOCATED n OUTSIDE OF THE PUMP ACCESS RISER, AND SHALL BE ACCESSIBLE FROM FINISHED S J I ! ; '•. � � GRADE. 7. ALL WIRE SPLICES SHALL BE COMPLETED WITH UL LISTED WATERPROOF CONNECTORS. / \ CONTROL PANEL: /N16o2696.67 THE INSTALLER SHALL PROVIDE AN ORENCO S1 SERIES CONTROL PANEL FOR THE E2499318.20' '•, �- % STA CORNER SEPTIC TANK PUMP, OR APPROVED EQUAL. THE CONTROL PANEL SHALL HAVE AN i ,�'6'j ' j' EVENT COUNTER AND AN ELAPSED TIME METER. THE CONTROL PANEL SHALL BEAR THE SEAL OF A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL), SUCH AS UL OR ETL. \-' 2. THE INSTALLER SHALL CONSULT THE OWNER AND/OR GENERAL CONTRACTOR FOR THE LOCATION OF THE CONTROL PANEL. THE CONTROL PANEL SHALL BE MOUNTED /< ON THE EXTERIOR OF THE BUILDING WITHIN SIGHT OF THE RESPECTIVE PUMPING SYSTEM. IF THERE IS NOT A SUITABLE LOCATION ON THE BUILDING, THE INSTALLER c• / \ SHALL CONTACT THE CIVIL ENGINEER FOR GUIDANCE ON AN ALTERNATE PANEL LOCATION. i 3. THE CONTROL PANEL SHALL BE MOUNTED AT A CONVENIENT HEIGHT TO ALLOW ACCESS AND MAINTENANCE. 4. THE CONTROL PANEL SHALL BE LOCATED SUCH THAT THE ALARM CAN BE READILY SEEN AND HEARD. / °Y -0 5. THE CONTROL PANEL SHALL BE CONNECTED TO A CONTROL BREAKER SEPARATE P FROM THE ALARM BREAKER AND FROM ANY OTHER CONTROL SYSTEM CIRCUITS. AN �j ELECTRICAL DISCONNECT SHALL BE PROVIDED WITHIN THE LINE OF SIGHT OF THE d n �o- / PUMP CHAMBER. BASIS OF DESIGN P SOIL TREATMENT AREA DESIGN CALCULATIONS / Qb = 225 GPD. USDA SOIL TEXTURE 3 (SANDY CLAY LOAM), SOIL TYPE 3. EFFLUENT TREATMENT LEVEL PRIOR TO DISPERSAL INTO STA = TL1; LTAR = 0.35. (225.0 GPD)/(0.35 GPD/SQUARE FEET) = 643'x 1.00 x 0.70 = 450 SQUARE FEET OF TREATMENT AREA REQUIRED, 480 SQUARE FEET PROVIDED. MAX. BED WIDTH = 12.0 FEET. NUMBER OF INFILTRATOR CHAMBERS AS 12 SQUARE FEET/CHAMBER = 38. SOIL TREATMENT AREA DOSING TOTAL DOSE VOLUME = 56.1") GALLONS (SOIL TREATMENT AREA DOSING VOLUME _ 56.25 GALLONS) ON, 1. 2. 3. 4. 5. 7. 8. 9. 10. 11. Graphic Scale 0 10 20 40 In Feet: 1" = 20' O O O O N N00 :3 � U E U) L O (n XCnC•� in 0 T7 E � c' `" oO N �s U W J � I •� Q� 0 c: E M 0 ^0 U W 0 0 J � E D z O � U H- U z O U O ILL z M Q > z J W ui s d 0 u d- a Job No. 2022.356-001 Drawn by: XX Print Date: 9.19.22 OC: XX PE: XX OWTS Plan v E m i Dwg No. 11 m