Loading...
HomeMy WebLinkAboutPermit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 335 Elk Range Road, Carbondale, CO 81623 Parcel No.: 239117401049 Owner Name: Ashley Bean and Jerry Daughty Owner Phone: (719) 510-1011 Designed by: Kumar and Associates, Inc. Designer Phone: (970) 945-7988 Number of Bedrooms: _3_ Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 525 ft2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-7871_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _11/9/2022____________________ Expiration Date_11/9/2023_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by Kumar and Associates, Inc. dated August 10, 2022. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will consist of an existing, two-compartment 1,000-gallon septic tank that is set level with access to grade. An effluent filter shall be added to the outlet tee of the existing septic tank as part of the construction of the new OWTS. Effluent will gravity flow to a distribution box set level with access to grade to distribute effluent to 540 ft2 of STA. The STA will consist of three gravelless chamber trenches consisting of 15 Quick4 chambers per trench (45 chambers total). Inspection ports are to be installed at the end of each trench. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 11/9/2022 Issued By: Garfield County Environmental Health Department Date