Loading...
HomeMy WebLinkAboutPermit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 5169 CR 154 Glenwood Springs _ Parcel No.: _219501100098 Owner Name: Loose Cannon LLC Owner Phone: (970) 618-8372 Designed By: SGM, Inc. Designer Phone: (970) 945-1004 Number of Bedrooms: _0_ Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 450 ft 2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-7909_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _12/29/2022____________________ Expiration Date_12/29/2023_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by SGM, Inc. dated May 31, 2022 and revised December 5, 2022. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a commercial building with up to 15 employees during an 8-hour work day. The system will consist of a new, two-compartment 1,500-gallon septic tank set level with access to grade with a high-head pump in the second chamber of the tank. Effluent will be pumped to an automatic distributing valve set at the high point of the system that will distribute effluent to 480 ft 2 of STA. The new STA will consist of one gravelless chamber bed, consisting of four rows of chambers with 10 chambers per trench (40 chambers total). Distribution laterals are to be 1 ½ inch Schedule 40 PVC, with orifices. Laterals are to be hung from the underside of the chambers with zip-ties. The orifices are to be facing upward, except for the first and last orifice (which shall face downward for drainage purposes). Inspection ports are to be installed at each corner of each bed. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 12/29/2022 Issued By: Garfield County Environmental Health Department Date