HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 5169 CR 154 Glenwood Springs _ Parcel No.: _219501100098
Owner Name: Loose Cannon LLC Owner Phone: (970) 618-8372
Designed By: SGM, Inc. Designer Phone: (970) 945-1004
Number of Bedrooms: _0_ Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 450 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7909_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _12/29/2022____________________ Expiration Date_12/29/2023_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by SGM, Inc. dated May 31, 2022 and revised December 5, 2022. Changes to the design
and permit must be approved by Garfield County Public Health and the designer prior to
construction.
The new OWTS will serve a commercial building with up to 15 employees during an 8-hour work day.
The system will consist of a new, two-compartment 1,500-gallon septic tank set level with access to
grade with a high-head pump in the second chamber of the tank. Effluent will be pumped to an
automatic distributing valve set at the high point of the system that will distribute effluent to 480 ft 2
of STA. The new STA will consist of one gravelless chamber bed, consisting of four rows of chambers
with 10 chambers per trench (40 chambers total). Distribution laterals are to be 1 ½ inch Schedule 40
PVC, with orifices. Laterals are to be hung from the underside of the chambers with zip-ties. The
orifices are to be facing upward, except for the first and last orifice (which shall face downward for
drainage purposes). Inspection ports are to be installed at each corner of each bed. Maintain all
setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
12/29/2022
Issued By: Garfield County Environmental Health
Department
Date