January 16,2023
PhilCastine
Project No. C1713
Subsurface lnvestigation and Onsite Wastewater Treatment System Design
3-Bedroom Residence + 1 Future Bedroom
1447 CR321
Garfield County, Colorado
Phit,
CBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The 38.647-acre property is located outside of Silt, in an area
where OWTSs are necessary.
Legal Description: Sectionl 19 Township: 6 Range: 93 NWNE, NENW; EXCEPT A PARCEL OF LAND
CONT. 36.26 AC. +/-, SAID PARCEL BEING MORE PARTICULARLY DESCRIBED PER SPECIAL
WARRANTY DEED RECEPTION NO. 921251Subdivision: SQUIRES MINOR SUB Lot; I AS PER
FINAL PLAT RECEPTION NO.9
Parcel lD: 2177-191-01-001
SITE CONDITIONS
The property is currently developed with an outbuilding with no plumbing. A 3-bedroom residence is
proposed with the possibility of an additional bedroom in the future.
The residence will be served potable water from a private well on the propeñy. The well is located on the
southern portion of the property, greater than 50-feet from the proposed septic tank and greater than
1O0-feet from the proposed soiltreatment area (STA). The water line has not been depicted on the site
plan, but no OWTS component will come within 25-feet of the water line.
There is a spring to the north of the property with a 1S-foot wide spring, pump house, and water line
easement running north of the property line onto Lot 2 of the Squires Minor Subdivision. The OWTS
component will come within 2S-feet of this easement.
The proposed soiltreatment area (STA) location has an approximate five percent slope to the northeast.
The proposed area is located in an open field vegetated with sparse native grasses.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
Page2
-; --f$::j': .-
Pt
-s,"#{fr1
I lP:ì"+-tt!
I*
View of property and well
SUBSURFACE
The subsurface was investigated on April 12,2022 by digging two soil profile test pit excavations (Test Pits)
A visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.l
The materials encountered in Test Pit #1 consisted of light brown silt clay loam to 3.O-feet, underlain by tan
silt clay loam to a maximum depth explored of 8.0-feet. No bedrock or groundwater was encountered.
The materials encountered in Test Pit #2 consisted of light brown silt clay loam to 2.O-feet, underlain by
tan silt clay loam to a maximum depth explored of 7.O-feet. No bedrock of groundwater was
encountered.
A sample of the soil was taken from Test Pit #1 at 3-feet below grade. Soil structure grade was
moderate. The soilformed a ball and a ribbon 1 to 2-inches in length before breaking. Soil structure
shape was blocky and consistence was friable. Soil texture was smooth.
STA sizing is based on SoilType 3, Silt Clay Loam with moderate structure grade. A long term
acceptance rate (LTAR) of 0.35 gallons per square foot will be used to design the OWTS.
I Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
I
Page 3
f.'.
'' -:íhr .'
Sieved sample
1 e 3 4 _:
, ¡(^
t.!
Test Pit #1
View of site
)iË\:
1í ffi
'¡!'.:'a
;*-: ..úi.)'r
'r*. .¡ "-
"r.q. Þ+ | a'-', '
. -'':* L.t-'t' ^å
1
I:{
Ribbon 1 to 2 inches in length before breaking
Page 4
Test Pit #2
.lÞ
. .r .,a
.d:
-" -t
.ì
ii
Backfill
DESIGN SPECIFICATIONS
Desiqn Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 75 GPD (4th bedroom) = 525 GPD
LTAR = 0.35 GPD/SF
525 GPD / 0.35 GPD/SF = 1500 SF
1500 SF x I .0 (gravity trenches) x 0.7 (chambers) = min. 1050 SF
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD will be used
Page 5
For the purposes of this OWTS design, Benchmark Elevation at approximate grade 5615' has been
established as 100' (Finished Floor). CBO lnc. should be notified of any discrepancies or problems with
grade elevations of proposed components during installation of the OWTS.
*Elevations are based upon standard installation practices. Component elevations may change ng
installation due to site conditions. Minimum grade refers to piping between components
The 4-inch diameter SDR-35 sewer line exiting the residence must have a double-sweep clean out and a
minimum 2o/o grade to the septic tank.
The system installation must include a minimum 125O-gallon, two-compartment septic tank with an
effluent filter on the outlet tee. We have provided specifications for a 15OO-gallon, two-compartment poly
lnfiltrator@ septic tank, but any state-approved poly or concrete septic tank is acceptable. Risers must
bring the manhole lids to grade for access. lf more than one riser is added to the septic tank, an
extension handle must be installed on the effluent filter.
Effluent will gravity flow to a distribution box, and then to six gravelless chamber trenches. The
distribution box must be accessible from grade and must have flow equalizers, or similar product,
installed on each outlet pipe in the distribution box to assure equalflow to each trench.
Each trench will consist of 15 'Quick 4' Plus Standard lnfiltrator@ chambers for a total of 90 chambers
and 1080 sguare feet of infiltrative area. There must be at least 4-feet of undisturbed soil between each
trench. lnspection ports must be installed at the beginning and end of each trench. Ports may be cut to
grade and placed in sprinkler boxes for access.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO lnc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
OWTS Gomponent Minimum Elevation
Primary Tank lnlet lnvert Approximate horizontal distance 18'/ min. 2%fall I
min.4.5" fall
Distribution Box Approximate horizontal distance 22' I min. 1% fall I
min. 2.75" fall
lnfiltrative Su¡face Approximate horizontal distance to furthest trench
43'l min. 1%fall / min.5.375" fal!
COMPONENT MANUFACTURER MODEL NO COMMENTS
Septic Tank lnfiltrator@ Item # lM-1530-2CP 1500-gallon,2-
compartment septic tank
lmin. 1250-qallons)
Risers and Lids Orenco@ Double-walled PVC
risers and lids
Effluent Filter Orenco@ 4-inch diameter Fullsize
Distribution Box Polylok Distribution box, lids,
rises, and (4)flow
equalizers
L;hambers lnflltratone Plus standard 90 'Qulck 4' chambers
Page 6
Construction must be according to Garfield County On-Site Wastewater Treatment System Regulations, the
OWTS Permit provided by Garfield County Building Department, and this design.
INSTALLATION CONTRACTOR
CBO lnc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS
CBO lnc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO lnc. should be notified 48 hours
in advance to observe the installation.
ln an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the STA. Untilvegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additionalwater is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
PageT
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
lf the design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk
of freezing. The pump shall have an audible and visual alarm notification in the event of excessively
high- water conditions and shall be connected to a control breaker separate from the high-water alarm
breaker and from any other control system circuits. The pump system shall have a switch so the pump
can be manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS:
The design is based on information submitted. lf soil conditions encountered are different from conditions
described in report, CBO lnc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO lnc.
r'l -
Carla Ostberg, MPH, REHS
N
DRAWINGS MUST BE USED IN
CONJUNCTION WITH DESIGN
LËTTER DATED O1 I 1612023
SCALE: 1 - 50'=0"
Non-Buildo6¡¿ ¿v¿q -J
{¿f 7.5',J tol'-
c.joì
t:
Area
of ItApproual
I
PROPERTY
l.f)
ol
Èl\-
Driuewag r ñ ^i ñ: _ . f :._
CBO lnc.
129 Calns Lane
Carbondale, ColoEdo 81623
Phone 970.309.5259
cala,ostbðrg@gmâll.com
Gastine Residence
1447 CR321
Garfield County, Colorado
ProjêctNumber: C1713
Dale: o1116t2923
Designed by: CgO
Drawn by; DD
w1 .0
Sheet 1 0F 4
N
F::ll
SCALE: 1" = 30L0"
'QUICK-4' CHAMBER TRENCHES. 6 TRENCHES
WITH 15 CHAMBERS PER TRENCH FOR A
TOTAL OF 90 CHAMBERS AND 1O8O SF.
4" DIA SDR-35 INSPECTION PORT AT
BEGINNING AND END OF EACH
HOLY CROSS EASEMENT
o"*ld/
ñ"/Ur/
TP2
4'DIA SDR-35 SEWER LINE TO
EACH TRENCH
(MrN. 1% SLOPE TO TRENCH)
+
DISTRIBUTION BOX
WITH ACCESS AT GRADE
+TPl
4" DIA SDR-35 SEWER LINE TO SÏA
(MrN. 1% FALL TO STA)
MIN STA
BM 100'
FF AAPROX,5615'
MIN. 1 25O.GALLON, TWO-COMPARTMENT
SEPTIC TANK WITH EFFLUENT SCREENÀ/¡
--t I
4" DIA SDR-35 SEWER PIPE WITH CLEANOUT
/ - (MtN 2% FALL TO TANK)
/'I
)
//////////PROPOSED DRIVEWAY
PROPOSED
4-BEDROOM
RESIDENCE
CBO lnc.
129 Cains Lâne
Cårbondale, Colorådo 81623
Phone 970.309.5259
carlâ.ostberg@gma¡l.com
Castine Resldence
1447 CR321
Gârfleld County, Colorado
Project Number: C1713
Daþ: 4111612023
Deslgned by: CBO
Drawn by: DD
w2.0
Sheet 2 0F 4
(:It{ },.CBO lnc.'129 Ca¡ns LaneCarbondale, ColoEdo 81623Phone 970.309.5259Érla.ostberg@gma¡|.æmDIA SDR.35INSPECTIONPORl4sotLILIMITÊXCAVATIONSCARIFIGRAVELLESS NUICK4'CHAMBER (4'x 3)4' DIA SDR-35 DISTRIBUÎON LINE TO EACHTRENCH (MrN. 1% SLOPE TOTRENCH)4" DIASDR-35EFFLUENT PIPE FROMSEPTICTANK/ñ CHAMBER 'IRENCH SEC'IION\lr--ffiE¡3END PUTE'QUtCK-4'CHAMBER {4'x 3')DISTRIBUTION BOX WßVALVE COVERBOX OR IRRIGATIONVALVE BOX AT GRAÐECAP OR THREADEDCLEANOUT ASSEMBLYCOMPACTBASE TO SUPPORTBOXPVC PIPE CUT TO4'FITUSE HOLE SAWTOCUT THRU TOP OFPIPÉS PLACEÞ INENDTOP PORT OF CHAMBER ÊNDPLATES/ãINSPECÎON PORI DEÌA|L\:ir-æ4" DIA SDR-35 INSPÊCTION PORTAT BEGINNING AND END OFEACH TRÈNCHFINISHED GRADE/^CHAMBER 'IRENCH PLAN\r-------trfEE24'MtN.4'DIA SDR-35 SEWER LINE(MrN 2olo SLOPE TO TANK,MtN. 1olo TO STA)SCREENEDOR SAND FORBEDDING3" MtN.I'MtN./I IRENCTI DETAIL\3/----rnirffi15 CHAMBERS PÊRÎRENCHIICastine Residence't447 CR321Garfield County, ColoradoProjectNumben Cl713lDaþi 01t16r2023loes¡gneo nv: ceolDrawn uv: oDw3.0Sheet 3 0F 4
CBO lnc.129 Cains LaneCarbondale, CdoEdo 81623Phone 970.309.5259carla.ostbe¡g@gmail.comDESIGNSTA TO WATER COURSE50'nlaSTATO WELL100'350'STATO HOUSE20'SEPTIC TANK TO WATER COURSE50'nlaSEPTIC TANK TO WELL50'313HOUSE TO SEPT|C TANK5'14',OWTS COMPONENTS ANDPHYSICAL FEATURESMINIMUM REOUIREDSETBACKAPPROXIMATE PROPOSEDSETBACK3€EDROOû| RÊSIDENCE + 1 FUTURE BEDROOM75 GPD x 2 PERSONSiBEDROOM x 3 BEDROOMS + 75 cPD (4th BEDROOM)WASTEWATER FLOW = 525 GPDTANK:MIN.1250 GALLONSUSE 125o-GALLON, TWO.COMPARTMENT CONCRETE SEPTIC TANK ORJsOO-GALLON, TWO,COMPARTMÊNT POLY SEPTIC TANKSOIL TREATMENT AREA (STA}:LONG TERM ACCEPTANCE RATE (LTAR) = 0.s5 GAU SFCALCULATED STA = Q/LTAR = 525 / 0.35 = 1500 SFGRAVITY, TRENCHES = I s00 SF X 1.0 = 1500 SFCHAMBERS = 1s00 SF X 0.7 = 1050 SF / 12 sF / CHAMBER = 88 CHAMBERSSIX GRAVELLESS CHAMBER TRENCHES15'QUICK 4'CHAMBERS IN EACH TRENCHTOTAL 90 'QUICK 4' CHAMBERSBOX AND COVER BROUGHT TO GRADECONCRETE LID.Ñf,SOIL PROFILE TEST PIT NO. 1SOIL PROFILE TEST PIT NO.2LEGENDnsilt dayloam-0-1-2-34LIGHl BROWN SILT CLAY LOAMLIGHT BROWN SILT CLAY LOAMBAFFLE ORANGLED PIPETO BE USEDAT INLÊT,.À DIS'IRIBUTON BOX DETAIL\3---ÊãæTAN SILT CLAY LOAMTAN SILT CLAY LOAM-5-6-7:!a!L.t"!10SLIP-ON PVCDO NOT GLUEINSULATEDTRACER WIREFINISHED GRADE4'DIASEWER LINENO GROUNDWATER OR BEDROCK ENCOUNTEREDDURING EXCAVATIONTOTANKHOUSE/ã,CLEAN OUT DETAILE/r-'.trriffiOUTLÊTSooooGastine Residence1447 CR321Garfield County, ColoradoProjectNumber: C1713Ðate: 0111612023Designed by: CBODrawn by: DDw4.0Sheet 4 0F 4
zfÀùtØà=Èúr+P2m8SHEETSITE PLANñsÌds/rrs¡!s"ns3ö2?0¡r--"Ì¡--oÛ16&S¡trItrFE-r=-êÆLruCtuntA Road 321@n2
fþE
AccountNumber R084999
ParcelNumber 277779IOIOOT
Acres 39
LandSqFt 0
TaxArea O24
2019 Mill Levy ó5.5390
Date created: I/20/2O23
Läst Data Uploaded: t/20/2O23 2:24:03 AM
D"u"looudbY&ï.., _, .. . ; L.
Garfield County, CO
Overuiew
Legend
; ' Parcels
Roads
Parcel/Account
Numbers
Owner Name
Lakes & Rivers
- County Boundary
Line
Physical Address 1447 327 COUNTY RD
RIFLE 81ó50
Owner Address SQUIRES,JESSEWADEJR
T4øTCOUNTy ROAD321
RTFLE CO 81ó50
2019Total ActualValue $67,660 Last2Sales
Date Price
7O/s/2O22 $O
4/8/2O7e $O
0787 rll R21 0786r
711 840031ll "\ , rrrll I I rr¡tt
lli,[,1,i ¡ l]i I
830031 5 21
CORPORATION lll '
.ROW-.:. !#-1,q.
1:
,,#,
2 1 3 1 771 92001 38
SANDRA 3785 LLC G@ñI'-¡---
j'j
;"ii't.''.iii"-j:¡:liì,l
'lrÌ
R024404
2177ß2A0214
j
.n ,_ _ Í!.' g:ì'' R009118
217719100495 R024395
217719140136
:
li
¿-.1,:,eirìil
' ,'.::: ,1'1.'
Ëii:¡
I
.2
BRUNËR
CRAIG Nrlii'
¡o3 R247333
217715400454
. R007577
21 7720301 001
$
ft t:.i
1120123, 12:23 PMqPublic.net - Garfield County, CO - Propefly Recod Gard: R084999r%qGarfield County, COSurnrvraryAccountParcelProp€rtyAddressLegalDescriptionAcresLard SqFtTaxAreaM¡ll l-e!ry9¡bdivisionR08499921779tOtOO|u47 32r COUNTY RD, R|FLE, CO 81ós0Section: 19 Township: ó Range: 93 NWNE, NENW; EXCEPTA PARCEL OF LAND CONT.3ó.2ó AC. +/-,SAID PARCEL BEING MORE PARTICULARLY DESCRIBED PER SPECIALWARRANTYDEEDRECEPTION NO. 921251Subd¡v¡s¡on: SQUIRES MINOR SUB Lot: 1AS PER FINAL PLAT RECEPTIONNO.938.647o246s.5390sQUIREs MINORSUBS,¡vr¡er1447 COUNTY ROAD 321RTFLE CO 81ó50LandUnitType SINGLE FAM.REs.-LAND - 1112 (RES¡DENTIAL PROPERry)Squâre Fæt 0,4ctma[ VaiueçAssessedYearLand Actuallmprovement ActualTotalActualÂssessecl ValuesAssessedYearLand Assessedlmprovement AssessedTotal AssessedTax å-listoryTaxYearTaxes Billed2022$ós,000.00$2,óó0.00$ó7,óó0.002022$4,520.00$18o.oo$4700.002022https://qpublic.schneidercorp.com/Application.aspx?ApplD=1038&LayerlD=2238'l&PageTypelD=4&PagelD=9447&Q=259274217&KeyYalue=R084999$308.041t3
1120123,12'.23 PMTra¡'¡sfersqPublíc.net - Garfield County, CO - Property Record Card: R084999Reception NumberSale DateIO/5/20224/8/2079!125/20187/8/207670/u2013lo/2/20t37/30/2æ78/75/2006u9/2æ62/9/20066/8/20054/4/2AOt8/7712æO8/t7/2æO6/9/7977LA/t4tt9&Deed TypePlatSTATEMENTOFAUTHORITYDEATH CERTIFICATEBENEFICIARY DEEDSPECIALWARRANTY DEEDSTATEMENT OFAUTHORITYQUITCLAIM DEEDQUITCLAIM DEEDEASEMENTAGREEMENTEASEMENTDEATH CERTIFICATEASSIGNMENTQUITCLAIM DEEDWARRANW DEEDDEEDBook - Page1835-15ó1844-6827772-9427697-339t207-5781205-5540497-05340201-00óóSale Price$o$o$o$o$o$o$o$o$o$o$o$o$o$o$o$oproperty Kelateei Fuhlic ü*cr"¡n-re*rtsFhatusNo data available for the followìng modules Buildings, Sketches.https://qpublic.schneidercorp.com/Application.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=9447&Q=259274217&KeyValue=R0849992t3
il24¡23,12:23 PMqPubl¡c.net - Garfield County, CO - Property Record Card: R084999{*IijËr)Ii};\i i,qilhttps://qpublic.schneidercorp"com/Application.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=9447&Q=259274217&KeyVgrlue=R0849993/3