HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 605 Lions Ridge Road, Carbondale, CO 81623 Parcel No.: _239130401015
Owner Name: Michael and Tammy Koski Owner Phone: (970) 948-2269
Designer: CBO, Inc. Designer Phone: (970) 309-5259
Number of Bedrooms: 5 Minimum Tank Capacity: 1,500-gallon
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7334_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _02/11/2022____________________ Expiration Date_02/11/2023_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, Inc. dated January 30, 2022. Changes to the design and permit must be approved
by Garfield County Public Health and the designer prior to construction.
The existing 3-bedroom residence on the site will be remodeled to a 5-bedroom residence and
utilize the existing OWTS on the parcel. As part of the project, the existing septic tank will be
abandoned in place, and replaced with a new two-compartment 1,500-gallon septic tank with access
brought to grade and an effluent filter in the outlet tee of the tank. Grade of the existing sewer line
exiting the tank shall be verified to ensure proper fall from the house to the tank. A cleanout shall be
installed between the house and the new septic tank if one is not already present. The effluent line
between the tank and the STA should be jetted to remove debris from the existing effluent line due
to years of use.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
02/11/2022
Issued By: Garfield County Environmental Health
Department
Date