Loading...
HomeMy WebLinkAboutEngineer's Letter 02.06.2023 February 6, 2023 Nick Shirley MM-Eight Construction (970) 230-9082 RE: Pinyon Mesa – Lot 76 380 Pinyon Mesa Drive, Glenwood Springs, Colorado 81601 Evolve Project #21.238C Nick, We were notified that the location of a floor joist’s proximity to the shower drain in the Master Bathroom resulted in notching the top flange of the TJI. The floor joists at this location are 11 7/8” TJI 360 @ 16”o.c. spanning approximately 17’-6” and the notch is 4ft from the south bearing location. We have reviewed the joist with a notched top flange and have found it to be acceptable if the notch is less than 30% of the top flange of the TJI 360. Should you have any further questions regarding this matter, please feel free to contact our office. Sincerely, Evolve Structural Design LLC Chris Bridges, E.I. Steve Edmiston, P.E., S.E. Project Engineer Principal 02/06/2023