HomeMy WebLinkAboutEngineer's Framing LetterI¡JE!E!Hb
E EISSEE:EEITEE¡
9TRUETURAL TN€INTEFS
Re
February 14,2023
RC Schneider Construction, lnc
Garage Outlookers
1965 Elk Sprlngs Road,
Glenwood Springs, Colorado
Gentlemen:
A representative of Weeks & Associates reviewed the 2x6 hem-fir outlooker framing at
the garage roof. Our review referenced the lnternational Building Code (2O15) and used
a roof dead load ol2C psf and a roof snow load of 4O psf. The 2x6 hem-fir outlookers
spaced at24" O.C. are sufficient.
lf we can be of further assistance please contact us.
Sincerely,
Weeks & Associates, lnc,
#¿¿Gary
Weeks
Gary G. Weeks, P.E.
Structural Engineer
4730 SorJth College /,ve, Suite 2O1 , Fort Collins, CO 80525
Phone (97o\ .'25.2422 - Fax (s7o) 225.2622
tlglt¡lly t¡gned by Gary Wælç
tNr 6.Gary Wæk!, ÊWe€l¡
& Artodatet lnç otl
qElLgary.wlsewældßß
m,FUS
D¡ts 2{t23.0¿1,1 @rO59
{rb0'
Evan Birschbach, E.l.T.
Staff Engineer