Loading...
HomeMy WebLinkAboutBuck Point Ranch_Permit_Irrigation-CD_s-revBuck Point Ranch_Permit_Irrigation-CD's-rev.dwg Carbondale CO. 81623 | 970.963.6520 311 Main Street, Suite 102 ECOLOGICAL DESIGN LAND PLANNING & URBAN DESIGN LANDSCAPE ARCHITECTURE 21254.01Buck Point Ranch1708 CR 121, CarbondaleCO 81623PROJECT NO: PHASE BUILDING PERMIT APPLICATION ADDENDUM 08.12.2022 Irrigation Construction NotesIRRIGATION SCHEDULE SYMBOL MANUFACTURER MODEL NO.DESCRIPTION DETAIL NO. RAIN BIRD RD-06-S-P30 WITH MPR FIXED SPRAY NOZZLE POPUP SPRAY HEAD 11 RAIN BIRD RD-12-S-P30 WITH MPR FIXED SPRAY NOZZLE HI-POP SPRAY HEAD 12 HUNTER I-20-06-SS WITH # STANDARD NOZZLE (BLUE)GEAR DRIVEN ROTOR 13 HUNTER I-20-12 WITH # NOZZLE HI-POP GEAR DRIVEN ROTOR 14 RAIN BIRD PESB W/ DECODER ELECTRIC CONTROL VALVE 10 & 19 RAIN BIRD 44-LRC QUICK COUPLING VALVE 5 HUNTER ACC-D (2-WIRE)ELECTRIC CONTROLLER 1 & 2 HUNTER WRF-CLIK WEATHER SENSOR DEVICE 3 N/S OLDCASTLE / CARSON REFER TO SPECIFICATIONS AND DETAILS VALVE BOXES VARIOUS N/S MATCO 201X MANUAL DRAIN VALVE 6 LINE SIZE - 21 2'' AND SMALLER GATE VALVE 7 CLASS 200 BE - 21 2" & SMALLER PVC MAINLINE 8 CLASS 200 BE PVC LATERAL 8 CLASS 160 PVC SLEEVING 9 #100 NSF POLY DRIP LATERAL 8 TORO BLUE STRIPE POLY DRIP TUBING -3 4" MIN. WIDTH 17 NETAFIM TLCV6-12 RINGS SPACED PER DETAIL SUBSURFACE DRIPLINE RING - TREE 16 RAIN BIRD XCZ-075-PRF OR XCZ-100-PRF DRIP VALVE ASSEMBLY 15 &19 DRIP LINE BLOW-OUT STUB 18 N/S RAIN BIRD XERI-BUG DRIP EMITTERS 17 N/S HUNTER ICD-100 VALVE DECODER 19 PAIGE P7354D (FOR HUNTER, BASELINE)2-WIRE DECODER CABLE N/S GROUNDING LOCATION 20 PRECISION PUMPING SYSTEMS POC #1: S##U1S005X00050-85V32X241ONS-2-SS, 50 GPM, 85 PSI, 5 HP, 240V, SINGLE PHASE (FLA: 38 AMPS) WET-WELL PUMP IR-106 DR-11 HDPE WET WELL INTAKE PIPE IR-106 APCO #50 AIR RELIEF VALVE 4 KASCO MARINE, INC., 715-262-4486, WWW.KASCOMARINE.COM AR6-XL, WITH RA-5DP CABINET ROBUST AIRE SYSTEM (9.6 CFM @ 10 PSI, 240, 6.8 AMPS -6 DIFFUSERS MAX.)21 KASCO 2 DIFFUSER AERATION ASSEMBLY TUBING 21 KASCO 5/8" SURE-SINK WEIGHTED TUBING 21 #6 #6 #6 #6 #2.0 #4.0 #4.0 #4.0 P AR GPM CONTROL VALVE SIZE CONTROLLER & STATION NO. POINTS OF CONNECTION & CONTROLLER DATA TAP NO.TAP SIZE (INCH) BACKFLOW PREVENTER SIZE (INCH) ASSOCIATED CONTROLLER CONTROLLER STATION COUNT PEAK FLOW REQUIREMENT (GPM) REQUIRED STATIC PRESSURE (PSI) TAP LOCATION - SEE SHEET 1 PUMP N/A A 96 50 85 IR-102 PUMP DATA TAP & PUMP NUMBER FLOW RATE (GPM) POWER REQUIREMENTS PRESSURE BOOST (PSI) 1 50 240V, 1 PHASE 85 Know what's below. before you dig.Call R 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management 1.DRAWINGS AND BASE INFORMATION ALL BASE AND PLANTING INFORMATION HAVE BEEN PROVIDED BY DHM DESIGN. THE CONTRACTOR IS RESPONSIBLE TO NOTIFY HYDROSYSTEMS*KDI OF ANY DISCREPANCIES BETWEEN THE UTILITY OR PLANTING PLANS AND THE IRRIGATION PLAN. IF CONTRACTOR FAILS TO NOTIFY HYDROSYSTEMS*KDI AND MAKES CHANGES TO THE IRRIGATION SYSTEM DESIGN, HE ASSUMES ALL COSTS AND LIABILITIES ASSOCIATED WITH THOSE FIELD CHANGES. REFER TO SPECIFICATIONS FOR ADDITIONAL PROJECT REQUIREMENTS. CONTACT IRRIGATION CONSULTANT FOR CURRENT SPECIFICATIONS IF NOT PROVIDED. 2.SYSTEM PRESSURE - HYDROSYSTEMS*KDI HAS BEEN INSTRUCTED TO USE STORAGE POND WITH A WET WELL FOR POC #1 WITH A REQUIRED STATIC WATER PRESSURE AT 85 PSI MIN. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PRESSURE PRIOR TO COMMENCING ANY CONSTRUCTION AND NOTIFY HYDROSYSTEMS*KDI OF ANY VARIANCE FROM THE STATED PRESSURE. IF CONTRACTOR FAILS TO FIELD VERIFY PRESSURE AND/OR NOTIFY HYDROSYSTEMS*KDI OR ANY VARIATIONS FROM THIS PRESSURE, THEN HE ASSUMES ALL CONSTRUCTION AND ENGINEERING COSTS ASSOCIATED WITH SYSTEM MODIFICATIONS REQUIRED TO ACCOMMODATE ACTUAL SITE PRESSURE. THE IRRIGATION SYSTEM HAS BEEN DESIGNED FOR A REQUIRED STATIC PRESSURE OF 85 PSI MINIMUM. SUBMERSIBLE PUMPING SYSTEM: HAS BEEN DESIGNED TO PRODUCE A FLOW OF POC#1 50 GPM (85 GPM FOR IRRIGATION / 15 GPM FOR FILTER FLUSH) AND A PRESSURE OF 85 PSI AT DISCHARGE OF THE PUMP. 3.IRRIGATION SYSTEM OPERATION INTENT - THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO IRRIGATE THE ESTABLISHED LANDSCAPE WITHIN A XXX NIGHT PER WEEK, XXX HOUR PER NIGHT WATERING WINDOW. ESTABLISHMENT WATERING WILL REQUIRE UP TO TWICE AS MUCH IRRIGATION FOR A FOUR TO SIX WEEK PERIOD. THE DESIGN IS BASED ON THE FOLLOWING PROJECTED WEEKLY APPLICATION RATES AFTER ESTABLISHMENT. THESE FIGURES ARE BASED ON A 30-YEAR AVERAGE WEATHER DATA AND WILL NEED TO BE ADJUSTED DUE TO SEASONAL CHANGES AND WEATHER CONDITIONS ABOVE AND BELOW THE AVERAGE VALUES UTILIZED. 4. ORNAMENTAL PLANTINGS 0.68" PER WEEK PEAK SEASON NATIVE SEED MIXES 0.82" PER WEEK PEAK SEASON (TWO SEASONS) IT IS THE INTENT OF THIS DESIGN THAT NATIVE AREAS WOULD ONLY BE IRRIGATED FOR ESTABLISHMENT. SYSTEM WILL REMAIN FOR USE DURING YEARS WITH LESS THAN NORMAL RAINFALL. 4.EQUIPMENT INSTALLATION - IT IS THE INTENT OF THIS DESIGN THAT ALL IRRIGATION EQUIPMENT BE INSTALLED WITHIN PROPERTY LIMITS AND WITHIN LANDSCAPED AREAS. INSTALLATION SHALL BE COORDINATED WITH OTHER UTILITY WORK, ALL OTHER UTILITIES SHALL TAKE PRECEDENCE OVER IRRIGATION LOCATION. ANY EQUIPMENT OTHER THAN VALVE BOXES OR SLEEVING THAT CONTAINS PIPE OR WIRES SHOWN OUTSIDE OF THESE LIMITS IS SHOWN IN THAT LOCATION FOR GRAPHICAL CLARITY ONLY. ALL VALVE BOXES SHALL BE INSTALLED A MINIMUM OF 2'-0" FROM EDGE OF ANY PAVED SURFACES UNLESS SPECIFICALLY INDICATED ON PLANS. BOXES INSTALLED IN OPEN TURF AREAS SHALL BE KEPT TO EDGES AND STAKED FOR REVIEW IF ALONG HIGH TRAFFIC AREAS. ALL VALVE BOXES SHALL BE PLACED A MINIMUM OF 3'-0" FROM THE CENTERLINE OF ANY DRAINAGE SWALE. ALL VALVE BOXES WITHIN PAVEMENT SHALL BE TIER 15 RATED BOXES FOR HEAVY DUTY NON-DELIBERATE TRAFFIC. BOX LID COLOR SHALL MATCH ADJACENT MATERIALS, I.E. GREEN IN TURF, TAN IN WOOD MULCH, GRAY IN STONE MULCH, PURPLE FOR RECLAIMED WATER SYSTEMS (IF REQUIRED). REFER TO LANDSCAPE PLANS FOR MATERIAL COLORS AND TYPES. ALL BOXES SHALL BE INSTALLED TO BE FLUSH WITH GRADE AND IN AN ORDERLY MANNER. WHERE MORTAR PAVING LIDS ARE INSTALLED ABOVE BOXES, IRRIGATION BOX WITH LID SHALL BE LOWERED TO ACCOMMODATE PAVING LID. REFER TO LANDSCAPE FOR ADDITIONAL INFORMATION, TO BE INSTALLED PER MANUFACTURE RECOMMENDATIONS. 5.MANUAL DRAIN VALVES - CONTRACTOR TO INSTALL ONE MANUAL DRAIN VALVE ON PRESSURE SUPPLY LINE DIRECTLY DOWNSTREAM OF BACKFLOW PREVENTER AND AT ALL LOW POINTS AND DEAD ENDS OF PRESSURE SUPPLY PIPING TO ENSURE COMPLETE DRAINAGE OF SYSTEM. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THESE LOCATIONS IN-FIELD AND INSTALLATION LOCATIONS SHALL BE NOTED ON AS-BUILTS. 6.DRIP IRRIGATION - REFER TO IRRIGATION DETAIL SHEET FOR DRIP EMITTER QUANTITIES / DRIP TUBING FLOW AND PLACEMENT. 7.UNLABELED PIPING - ALL UNLABELED LATERAL PIPING SHALL BE 1" MINIMUM UNLESS OTHERWISE NOTED. 8.SLEEVING - ALL SLEEVING UNDER PAVED SURFACES SHOWN ON PLANS IS BY CONTRACTOR UNLESS OTHERWISE NOTED. SLEEVING SHALL BE INSTALLED IN THE SIZES AND QUANTITIES SHOWN ON PLANS OR BASED ON THE SCHEDULE BELOW. WHERE SLEEVES ARE SHOWN, BUT NOT LABELED, FOLLOW THE SCHEDULE BELOW. ALL MAINLINE, CONTROL WIRES AND DRIP LINES UNDER PAVED SURFACES ARE TO BE INSTALLED IN SLEEVING. ALL MAINLINE SLEEVE LOCATIONS TO INCLUDE A SEPARATE WIRE SLEEVE. SLEEVED PIPE SIZE/WIRE QUANTITY REQUIRED SLEEVE SIZE & (QUANTITY) 3 4" - 11 4" PIPING 2" PVC (1) 11 2" - 2" PIPING 4" PVC (1) 212" - 3" PIPING 6" PVC (1) 2-WIRE CABLE 2" PVC (1) 9.2-WIRE SYSTEM NOTES - CONTRACTOR SHALL INSTALL ALL TWO-WIRE COMPONENTS PER MANUFACTURER'S RECOMMENDATIONS AND STANDARDS. 9.1.CONTRACTOR SHALL USE ONLY MANUFACTURED 2-WIRE DECODER CABLE (SEE SCHEDULE FOR SPECIFIC 2-WIRE CABLE). 9.2.ONLY USE SINGLE STATION DECODERS (SEE SCHEDULE FOR SPECIFIC MODEL). 9.3.ONLY USE SENSOR DECODER FOR FLOW SENSOR (SEE SCHEDULE FOR SPECIFIC MODEL) IF INDICATED ON PLANS. 9.4.LOOP 5' OF 2-WIRE DECODER CABLE INTO ALL VALVE BOXES (WITH DECODERS AND SPLICES) FOR MAINTENANCE. 9.5.LOOP 2' OF 2-WIRE DECODER CABLE AS AN EXPANSION LOOP AT ALL CHANGES OF DIRECTION. 9.6.USE ONLY 3M DBR-6 WATERPROOF CONNECTORS ON ALL WIRE SPLICES AND ALL WIRE SPLICES ARE TO BE MADE WITHIN A VALVE BOX WITH CONTROL VALVES OR A SEPARATE 10" ROUND VALVE BOX FOR WIRE SPLICES. 9.7.INSTALL SURGE PROTECTOR RODS OR PLATES 8 LF. PERPENDICULARLY FROM VALVES, DECODERS, AND COMMUNICATION WIRE. WHERE 8 LF IS NOT AVAILABLE, REFER TO ASIC GUIDELINES FOR PLATE LAYOUT. 11.8.GROUNDING SHALL BE IN AN IRRIGATED AREA. 11.9.GROUND ALL DECODERS AND DECODER WIRE A MINIMUM OF EVERY 1000' OF WIRE OR EVERY 12TH DECODER AND AT ALL ENDS OF 2-WIRE DECODER CABLE RUN. 12.PLANS AND SPECIFICATIONS - CONTRACTOR RESPONSIBLE TO ENSURE WORK CONFORMS TO PLANS AND SPECIFICATIONS. AT ONSET OF CONSTRUCTION, VERIFY PLANS ARE CURRENT. WHERE REQUIRED BY CITY OR TOWN, CONTRACTOR SHALL CONSTRUCT ONLY OFF CITY OR TOWN STAMPED PLANS. REVISIONS TO CITY OR TOWN STAMPED PLANS SHALL CONFORM TO CITY OR TOWN FIELD CHANGE PROCEDURES AND DOCUMENTATION. 13.SIMULTANEOUS ZONE OPERATION - THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO OPERATE MULTIPLE ZONES SIMULTANEOUSLY BASED ON INDIVIDUAL ZONE FLOW. THE DESIGN IS INTENDED TO OPERATE MULTIPLE VALVES, UP TO THE MAXIMUM FLOW IN THE POINT OF CONNECTION NOTE. REFER TO CONTROLLER SPECIFICATION FOR MAXIMUM SIMULTANEOUS VALVE COUNT. 14.WATER BUDGETS AND PROJECTIONS - HYDROSYSTEMS-KDI HAS BASED THE IRRIGATION DESIGN AND THE ASSOCIATED PROJECTED WATER USE UPON SUCH FACTORS AS CITY OR WATER DISTRICT IMPOSED REQUIREMENTS, PUBLISHED PLANT SPECIES WATER NEEDS, SELECTED IRRIGATION METHOD EFFICIENCIES AS REPORTED BY INDEPENDENT TESTING FACILITIES, HISTORICAL WEATHER DATA FOR THE PROJECT LOCATION, AND PROPER MAINTENANCE PROCEDURES. HYDROSYSTEMS*KDI IS NOT RESPONSIBLE, AND ACCEPTS NO RESPONSIBILITY, FOR THE ACTUAL WATER USAGE VARIATION THAT IS A RESULT OF FIELD MODIFICATIONS TO THE SYSTEM NOT MATCHING CONSTRUCTION DOCUMENTS, IMPROPER MAINTENANCE, WASTE DUE TO SYSTEM DAMAGE OR VANDALISM, OR WEATHER CONDITIONS THAT DEVIATE FROM PUBLISHED 30 YEAR HISTORICAL AVERAGES. DIRECTORY IRRIGATION SCHEDULE IR-100 IRRIGATION NOTES IR-100 IRRIGATION PLANS IR-101 - IR-102 IRRIGATION DETAILS IR-103 - IR-105 IRRIGATION PUMP DETAILS IR-106 A W AERATION SYSTEM DESIGN NOTES IRRIGATION PLAN IR-101 G 2. 1. 3. CONTRACTOR SHALL SUPPLY AND INSTALL SPECIFIED EQUIPMENT CONTRACTOR IS RESPONSIBLE FOR ALL CONNECTIONS BETWEEN ELECTRICAL SUPPLY AND AERATION STATION. CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION BETWEEN SUPPLIER AND AERATION MANUFACTURER TO COMPLETE THE INSTALLATION. 4.REFER TO MANUFACTURES SPECIFICATIONS FOR ADDITIONAL INSTALLATION INFORMATION AND HANDLING REQUIREMENTS. ALL ELECTRICAL WIRING REQUIRED FOR PUMP SYSTEM CONTROL ENCLOSURE SHALL BE IN RIGID ELECTRICAL CONDUIT. WORK SHALL CONFORM TO ALL APPLICABLE ELECTRICAL CODES. FEES, DIAGRAMS AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. 5. PUMP SYSTEM CONTROL PANEL IS A NEMA 3R INDUSTRIAL ELECTRICAL ENCLOSURE WITH 12'' SUPPORT LEGS AND REQUIRES A MIN 6'' THICK REINFORCED CONCRETE MOUNTING PAD WITH ELECTRICAL CONDUITS. SUBMIT SHOP DRAWINGS AS NEEDED. 6. 7. 8.. 9. NEW ELECTRICAL SUPPLY, EQUIPMENT AND INSTALLATION TO PUMPING SYSTEM IS BY CONTRACTOR. ELECTRICAL PERMITS SHALL BE OBTAINED, SUBMITTED AND PAID BY CONTRACTOR CONTRACTOR IS RESPONSIBLE FOR ALL ADDITIONAL EQUIPMENT FOR THE INSTALLATION OF THE PUMPING SYSTEM AND ENCLOSURE THAT IS NOT SUPPLIED BY PUMP MANUFACTURER. ELECTRICAL ENGINEERING AND DRAWINGS REQUIRED FOR PERMITTING SHALL BE PREPARED AND SUBMITTED BY CONTRACTOR. 10.CONTRACTOR SHALL VERIFY ALL GRADE ELEVATIONS FOR NEW WORK PRIOR TO ORDERING ANY MATERIALS. CONTACT CONSULTANT FOR ANY DIFFERENCES FROM ELEVATIONS CALLED ON PLAN. 11.ALL AERATION EQUIPMENT SHALL BE INSTALLED PER SUPPLIERS AND MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS. (KASCO MARINE, INC., 715-262-4486, WWW.KASCOMARINE.COM) 21 2'' 21 2'' 21 2'' 21 2'' 21 2'' 21 2'' (1)4''(1)2'' (1)4''(1)2'' (1)4''(1)2'' 48 2" A24 32 1.55" A23 32 1.5" A22 40 2" A18 48 2" A20 30 1.5" A21 48 2" A14 48 2" A17 40 2" A6 36 1.5" A7 21 1" A9 42 2" A12 4 1" A13 6 1" A11 5 1" A5DR1" A15 DR 1" A16 DR 1" A8 DR 1" A10 DR 1" A4 #4.0 #4.0 #4.0 #4.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0#8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 G G G (1)2'' (1)2'' (1)2'' (1)2'' (1)2'' (1)4''(1)2'' (1)4''(1)2''(1)4''(1)2''21 2''21 2''21 2'' 1'' 11 4'' 112'' 2'' 11 2'' 1'' 1'' 1'' 1''1''114''11 2''112'' 2'' 2'' 2'' 1'' 48 2" A19 2''112'' 1'' 11 ''11 '' 2'' 1'' 2'' 2'' 2'' 2'' 2'' 2'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 114'' 114'' 114'' 114'' 114'' 11 4'' 114'' 11 4'' 114'' 114'' 114'' 11 4'' 114'' 114'' 112'' 11 2'' 114'' 11 2'' 112'' 11 2'' 11 2'' 11 2'' (1)2'' 112'' 112'' 112''112'' 112'' 112'' 11 2'' 1''1'' 11 4'' 11 4'' Scale: 1" = 20'-0" 0'10'20'40' IRRIGATION PLAN IR-101 Buck Point Ranch_Permit_Irrigation-CD's-rev.dwg Carbondale CO. 81623 | 970.963.6520 311 Main Street, Suite 102 ECOLOGICAL DESIGN LAND PLANNING & URBAN DESIGN LANDSCAPE ARCHITECTURE 21254.01Buck Point Ranch1708 CR 121, CarbondaleCO 81623PROJECT NO: PHASE BUILDING PERMIT APPLICATION ADDENDUM 08.12.2022 IRRIGATION PLAN 1 SCALE: 1" = 20'-0" 0A7C+ L,1E: ':* 2  S+7 ,5-102 Know what's below. before you dig.Call R 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR-100 IRRIGATION NOTES IR-100 IRRIGATION PLANS IR-101 - IR-102 IRRIGATION DETAILS IR-103 - IR-105 IRRIGATION PUMP DETAILS IR-106 P 731 4 731 6 731 8 73 2 0 731 2 A R 731 0 73 3 0 21 2'' 21 2'' 21 2'' 21 2''21 2'' 21 2'' 21 2'' 21 2'' 48 2" A29 40 2" A26 40 2" A30 40 2" A32 48 2" A33 48 2" A3 8 1" A27 4 1" A31 4 1" A2 #4.0 #4.0 #4.0 #4.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0#8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 #8.0 G G AR 26 1.5" A25 DR 1" A28 DR 1" A1 1'' 1''114'' 11 2'' 11 2'' 112'' 2'' 1'' 1'' 114'' 114'' 1 2'' 11 2'' 112'' 1'' 1'' 11 4'' 114'' 11 2'' 112'' 114'' 114'' 114'' 114'' 114'' 11 4'' 11 2'' 112'' 112'' 2'' 2'' 2'' 2'' 2'' 2'' 2'' 2'' 2'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 1'' 114'' 11 4'' 11 4'' 114'' 114'' 114'' 11 4'' 114'' 114'' 114'' 11 4'' 114'' 114'' 11 4'' 114'' 11 4'' 11 4'' 11 4'' 114'' 11 4'' 114'' 112'' 112'' 11 2'' 112''(1)4'' 112'' 112'' 11 2'' 112'' 11 2'' 112'' 11 2'' 11 2'' 11 2'' IRRIGATION PLAN IR-102 Buck Point Ranch_Permit_Irrigation-CD's-rev.dwg Carbondale CO. 81623 | 970.963.6520 311 Main Street, Suite 102 ECOLOGICAL DESIGN LAND PLANNING & URBAN DESIGN LANDSCAPE ARCHITECTURE 21254.01Buck Point Ranch1708 CR 121, CarbondaleCO 81623PROJECT NO: PHASE BUILDING PERMIT APPLICATION ADDENDUM 08.12.2022 POINT OF CONNECTION #1- POND PUMP CONTROLLER LOCATION "A" PEDESTAL MOUNT ONE HUNTER, 2-WIRE, CONTROLLER AT INDICATED LOCATION. CONTROLLER SHALL BE PROGRAMMED TO OPERATE MULTIPLE DRIP VALVES SIMULTANEOUSLY TO STAY WITHIN THE MAXIMUM 48 HOURS PER WEEK WATER WINDOW. CONTROLLER MAY OPERATE UP TO (1-2) DRIP VALVES SIMULTANEOUSLY. 120 VOLT POWER IS AVAILABLE WITHIN 25 LF. OF CONTROLLER LOCATION FROM NEW ELECTRICAL PANEL (RE: ELECTRICAL). SEPARATE ELECTRICAL METER (IF REQUIRED), WIRE/CONDUIT, AND POWER CONNECTION TO CONTROLLER IS BY CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES. FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. FINAL CONTROLLER LOCATION SHALL BE APPROVED BY OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. CONTRACTOR TO INSTALL NEW WET WELL ASSEMBLY WITH SELF CLEANING IN TAKE SCREEN. A SUBMERSIBLE PUMP STATION PACKAGE W/ FILTRATION IN A VAULT WILL BE INSTALLED AT THE APPROXIMATE LOCATION. PUMP POWER PANEL TO BE INSTALLED NEXT TO IRRIGATION CONTROLLER, AS SHOWN. 240V -SINGLE PHASET POWER IS AVAILABLE WITHIN 25 LF. OF PUMP LOCATION FROM NEW ELECTRICAL PANEL (RE: ELECTRICAL). SEPARATE ELECTRICAL METER (IF REQUIRED), WIRE/CONDUIT, AND POWER CONNECTION TO CONTROLLER IS BY CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES. FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. EXTEND CLASS 200 PVC MAINLINE AS SHOWN. Peak Flow - 50 GPM, STATIC PRESSURE - 85 PSI MIN. A 1 1 A Scale: 1" = 20'-0" 0'10'20'40'IRRIGATION PLAN 2 SCALE: 1" = 20'-0" Know what's below. before you dig.Call R 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR-100 IRRIGATION NOTES IR-100 IRRIGATION PLANS IR-101 - IR-102 IRRIGATION DETAILS IR-103 - IR-105 IRRIGATION PUMP DETAILS IR-106 0A7C+ L,1E: ':* 1  S+7 ,5-101 SEE PUMP DETAIL SHEET IR-106 AR AERIATION SYSTEM CONTRACTOR TO INSTALL ALL AERATION EQUIPMENT, PER SUPPLIERS AND MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS (KASCO MARINE, INC., 715-262-4486, WWW.KASCOMARINE.COM), AT THE APPROXIMATE LOCATION. POWER PANEL TO BE INSTALLED NEXT TO IRRIGATION CONTROLLER, AS SHOWN. 240V -SINGLE PHASE POWER IS AVAILABLE WITHIN 25 LF. OF CONTROLLER LOCATION FROM NEW ELECTRICAL PANEL (RE: ELECTRICAL). SEPARATE ELECTRICAL METER (IF REQUIRED), WIRE/CONDUIT, AND POWER CONNECTION TO CONTROLLER IS BY CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES. FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. AR IRRIGATION DETAILS IR-103 Buck Point Ranch_Permit_Irrigation-CD's-rev.dwg Carbondale CO. 81623 | 970.963.6520 311 Main Street, Suite 102 ECOLOGICAL DESIGN LAND PLANNING & URBAN DESIGN LANDSCAPE ARCHITECTURE 21254.01Buck Point Ranch1708 CR 121, CarbondaleCO 81623PROJECT NO: PHASE BUILDING PERMIT APPLICATION ADDENDUM 08.12.2022 PEDESTAL MOUNT AREA IRRIGATED CLOSEST SURFACE OF ACCESS PANEL. CORRESPONDING WITH FIELD UNIT # ON OUTSIDE INSTALL 4" HT. SELF ADHESIVE VINYL LETTERING RECOMMENDED BY MANUFACTURER. VALVE BOX (TYPICAL). QUANTITY AS #6 BARE COPPER GROUNDING WIRE ROD W/ BRONZE CLAMP & 10" ROUND 5/8"x8 FT. COPPER-CLAD GROUNDING 1" SWEEP ELL - GROUND WIRE 3" SWEEP ELL - CONTROL WIRES CONCRETE PAD 5" 1" CONTROLLER FINISH GRADE 1ELECTRIC CONTROLLER - MANUFACTURER"S RECOMMENDATIONS AND GROUND PROTECTION FOR CONTROLLER IN ACCORDANCE WITH CONTRACTOR TO GROUND AND PROVIDE SURGE 6" 3/4" PVC CONDUIT W/ SWEEP ELL - 120v SERVICE SLOPE 0.5% 6" 18" 6"TO LOCAL CODE. ALL ELECTRICAL WORK TO CONFORM GFI RECEPTACLE WITHIN PEDESTAL INSTALL A DISCONNECT SWITCH AND 120 VOLT NOTES: ROD(S) SHOWN. CONTROLLER GROUNDING SHALL COMPLY W/ MANUFACTURER'S SPECIFICATIONS. PLAN VIEW 3/4" NON-METALLIC LIQUIDTITE CONDUIT W/ MALE ADAPTERS (2) AND LOCK RINGS, WASHERS CONTROL WIRES - NEATLY BUNDLE WIRING & SECURE W/ LOCKING WIRE TIES PROVIDE 48" LENGTH OF ALL SPARE WIRES WITHIN PEDESTAL, NEATLY COILED. DISCONNECT SWITCH & RECEPTACLE FINISH GRADE CONTROLLER GROUNDING SATELLITE CONTROLLER(S) #6 CONTINUOUS SOLID BARE COPPER WIRE (TYPICAL) CADWELD GT1161G "ONE SHOT" WELD 5 8" x 8FT COPPER-CLAD GROUNDING ROD #6 CONTINUOUS SOLID BARE COPPER WIRE (TYPICAL) COPPER GROUNDING PLATE 4"x96"x0.0626" GROUND ENHANCEMENT MATERIAL PER MANUFACTURER'S RECOMMENDATIONS 1' 8'15' 3' 2 Know what's below. before you dig.Call R 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR-100 IRRIGATION NOTES IR-100 IRRIGATION PLANS IR-101 - IR-102 IRRIGATION DETAILS IR-103 - IR-105 IRRIGATION PUMP DETAILS IR-106 NOTE: MOUNT RAIN SENSOR RECEIVER PER CONTROLLER DETAIL. 10' MIN. 36" MIN. 12" DIAMETER CONCRETE BASE - FORM W/ SONA-TUBE OR EQUAL. POST SHALL BE CENTERED WITHIN BASE. FINISH GRADE 112" DIAMETER SCH. 40 GALVANIZED STEEL POST 112"x12" FxF SCH. 40 GALVANIZED TEE W/ 112" MIPT PLUG WIRELESS RAIN SENSOR (MODEL PER SCHEDULE) - TOP OF SENSOR TO BE ABOVE RAIN SHADOW OF BUILDING GUTTERS, TREES AND/OR ANY OTHER OBSTRUCTIONS WEATHER SENSOR 3POLE MOUNTED - Wireless PVC FITTINGS AND ALL NIPPLES APPLY TEFLON TAPE TO ALL MALE THREADED PVC PRESSURE MAINLINE SEE TECHNICAL SPECIFICATIONS 3/4" CRUSHED GRAVEL SUMP 3/4"x4" PVC NIPPLE SCH. 80 3/4" MxF SCH.40 PVC 90 ELL SOIL BLANKET COVERING SUMP 3/4" BRASS GLOBE VALVE FOR SUMP SIZE 6 4" FINISH GRADE 3/4"x6" SCH. 80 GALVANIZED STEEL NIPPLE 3/4"xCL PVC NIPPLE SCH. 80 (2) 3/4" FxF SCH.80 PVC 90 ELL (2) 2" CL160 PVC ACCESS SLEEVE - 3/4" CRUSHED GRAVEL SUMP TECHNICAL SPECIFICATIONS THE LETTER "D" IN LID- REFER TO 10" ROUND VALVE BOX - BRAND LENGTH AS REQUIRED 1 CU. FT. 2" VALVE MARKER QUICK COUPLING VALVE 5 LASCO #G 13S-212 UNITIZED SWING JOINT PRESSURE MAINLINEx1" PVC SERVICE TEE - SOLVENT WELD OR GASKETED FITTING REFER TO SPECIFICATIONS 1/2"X12" REBAR STABILIZING STAKE TYPICAL TWO SIDES PER QUICK COUPLING VALVE LOCATION W/ BRASS INSERT STABILIZER ELBOW. PROVIDE WITH 1" MIPT INLET QUICK COUPLING VALVE BRAND "QC" INTO VALVE BOX FINISH GRADE 10" ROUND VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. 3" 1" BRASS NIPPLE LENGTH AS REQUIRED 2" OF BOTTOM OF QCV LID SUMP - FILL BOX TO WITHIN 3/4" CRUSHED GRAVEL 2" APPLY TEFLON TAPE TO ALL THREADED NIPPLES LINE SIZE BRASS COUPLING FINISH GRADE 2" 3" 10" ROUND VALVE BOX. BRAND "GV" ON LID OF VALVE BOX. REFER TO TECHNICAL SPECIFICATIONS. GATE VALVE W/ CROSS HANDLE AND SOLID WEDGE DISC. 3 4" CRUSHED GRAVEL SUMP - FILL BOX TO WITHIN 2" OF TOP OF 6" PVC ACCESS SLEEVE∅ 6" CLASS 160 PVC SLEEVE BOTTOM TO BE NOTCHED AND CONTACT TOP OF PRESSURE MAINLINE PVC PRESSURE MAINLINE SCH. 40 PVC MALE ADAPTER (2) - SIZE TO EQUAL GATE VALVE DIAMETER UNDISTURBED SOIL GATE VALVE 8TRENCH BACKFILL MATERIAL (TYPICAL) CONTROL WIRES -2 WIRE PVC MAINLINE FINISH GRADE 18" 12" 24" ROTOR LATERAL PIPING SPRAY HEAD LATERAL PIPING NOTE: REFER TO TECHNICAL SPECIFICATIONS FOR MINIMUM TRENCH WIDTHS. 7 MANUAL DRAIN VALVE FINISH GRADE AIR RELIEF VALVE 12" RECTANGULAR VALVE BOX W/ EXTENSION. BRAND "AR" IN VALVE BOX LID - REFER TO TECHNICAL SPECIFICATIONS. 4" APCO #50 - 1" AIR RELEASE VALVE W/ TWO SCH. 40 PVC MxF 90 ELLS INSTALLED ON AIR OUTLET. SET ASSEMBLY IN PLUMB POSITION. 1"xCL SCH. 80 PVC NIPPLE & 1" FxF SCH. 80 PVC ELL 1"x4" SCH. 80 PVC NIPPLE 1" BRONZE BALL VALVE 1"xCL SCH. 80 PVC NIPPLE 3 4" CRUSHED GRAVEL SUMP - FILL TO BOTTOM OF BALL VALVE 1" FxF SCH. 80 PVC ELL 1" SCH. 80 PVC NIPPLE - LENGTH AS REQUIRED DUCTILE IRON GASKETED SERVICE TEE (LINE DIA.x1") PVC PRESSURE MAINLINE NOTE: AIR RELEASE ASSEMBLY SHALL REST ON GRAVEL SUMP FIELD-LOCATE AIR RELEASE AT HIGH POINT IN MAINLINE PIPING APPLY TEFLON TAPE TO ALL MALE THREADED FITTINGS AND NIPPLES 4 IRRIGATION DETAILS IR-104 Buck Point Ranch_Permit_Irrigation-CD's-rev.dwg Carbondale CO. 81623 | 970.963.6520 311 Main Street, Suite 102 ECOLOGICAL DESIGN LAND PLANNING & URBAN DESIGN LANDSCAPE ARCHITECTURE 21254.01Buck Point Ranch1708 CR 121, CarbondaleCO 81623PROJECT NO: PHASE BUILDING PERMIT APPLICATION ADDENDUM 08.12.2022 Know what's below. before you dig.Call R 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR-100 IRRIGATION NOTES IR-100 IRRIGATION PLANS IR-101 - IR-102 IRRIGATION DETAILS IR-103 - IR-105 IRRIGATION PUMP DETAILS IR-106 IRRIGATION SLEEVING B A 36" ROUGH GRADE 12" MIN. 24" MIN. CURB AND GUTTER - IF APPLICABLE PAVED SURFACE PVC SLEEVING (TYPICAL) NOTE: 1) ALL SLEEVING TO BE CLASS 160 BE PVC, SIZE AS NOTED. 2" PVC PIPE SLEEVE MARKER- INSTALL AT BOTH ENDS OF EACH SLEEVE LOCATION AND EXTEND AT LEAST 3' ABOVE GRADE. SPRAY EXPOSED PORTION OF MARKER WITH GREEN FLUORESCENT PAINT. 9 SEAL ENDS OF SLEEVE WITH CLOTH DUCT TAPE (TYPICAL) C INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLE SLEEVES ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DO NOT STACK SLEEVES VERTICALLY. 2) 3/4'' CRUSHED GRAVEL SUMP - FILL BOX TO TECHNICAL SPECIFICATIONS. RECTANGULAR VALVE BOX - BRAND BOX LID W/ CONTROLLER AND STATION NUMBER - REFER TO BOTT0M OF VALVE BODY. ALL VALVE ASSEMBLY COMPONENTS SHALL BE CLEARLY VISIBLE WITHIN VALVE BOX DRIP VALVE ASSEMBLY INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN ENTIRE ASSEMBLY WITHIN BOX. NO VALVE BOX EXTENSIONS WILL BE ACCEPTED PROVIDE 3''-4'' CLEARANCE BETWEEN TOP OF CONTROL VALVE SOLENOID AND BOTTOM OF VALVE BOX LID. TOP OF VALVE BOX TO BE FLUSH WITH FINISH GRADE NOTE: 15 SCH. 80 VERTICAL NIPPLE - LENGTH AS FxF SCH. 40 PVC 90d ELL W/ 1"x3/4" MIPTxINSERT PVC ADAPTER STAINLESS STEEL WORM GEAR OR PINCH PRESSURE SUPPLY LINE RAIN BIRD 1" DVX CONTROL VALVE DRIP TUBING/PIPING - REFER TO SCHEDULE 1" PVC BALL VALVE (MIPTxMIPT) REQUIRED IN-LINE WYE FILTER CLAMP VALVE BOX SHALL NOT REST ON DRIP TUBING WATER PROOF CONNECTION DECODER SECURED TO PVC PIPE TWO BLACK WIRES TO VALVE SOLENOID DECODER CABLE FROM PREVIOUS DECODER BLACK WIRES TO VALVE SOLENOID DECODER CABLE PATH TO NEXT DECODER IN-LINE PRESSURE REGULATOR RAIN BIRD PSI-L40X RAIN BIRD RBY-100-200MX BLAZING WIRE CONNECTORS -BVS-2 NOTE: DIAMETERS OF BALL VALVES, PVC FITTINGS AND NIPPLES SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER. VALVE BOXES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS AND HARD SURFACES WHERE APPLICABLE. APPLY TEFLON TAPE TO ALL MALE THREADED FITTINGS AND THREADED NIPPLES. ELECTRIC CONTROL VALVE TWO WIRE SYSTEM PVC LATERAL - 45 ELL TO SPECIFIED DEPTH SCH. 40 PVC REDUCING MALE ADAPTER RECTANGULAR VALVE BOX. BRAND LID WITH CONTROLLER & STATION #. REFER TO TECHNICAL SPECIFICATIONS. CENTER BOX OVER ASSEMBLY. PVC BALL VALVE - FIPTxFIPT 3 4" CRUSHED GRAVEL SUMP - FILL BOX TO BOTTOM OF VALVE BODY SCH. 80 PVC NIPPLE - LENGTH AS REQUIRED SERVICE TEE - SOLVENT WELD OR GASKETED FITTING - REFER TO SPECIFICATIONS ELECTRIC CONTROL VALVE 4" FINISH GRADE TWO BLACK WIRES TO VALVE SOLENOID DECODER DBR-6 (2) PROVIDE 60" CONTINUOUS COILS OF ALL "MAINTENANCE" SPARE CONTROL/COMMON WIRING WITHIN VALVE BOX (PER DECODER) TWO-WIRE PATH TO NEXT DECODER TO EARTH GROUNDING LOCATION INSTALLED PER ASIC GUIDELINES. 1 PER 12 DECODERS OR EVERY 1000 ft TWO-WIRE PATH TO NEXT DECODER DBR-6 (2) DBR-6 10 HI-POP SPRAY HEAD PVC THREADED FITTINGS APPLY TEFLON TAPE TO ALL MALE NOTE: SET HEAD PERPENDICULAR TO \" MALExBARB 90 ELBOW \" MALExBARB ADAPTER LINE SIZEx\" SLIPxFIPT FITTING PVC LATERAL PIPING W/ SCH. 40 PVC \" FLEX PIPE (6"-12" LENGTH) FINISH GRADE 12 12" HI-POP SPRAY HEAD CURB AND GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE SET BOTTOM OF CAP AT GRADE 3" SWING JOINT CONNECTION SIDE INLET IS NOT TO BE UTILIZED FOR SET LIP AT FINISHED GRADE CURB AND GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE GEAR DRIVEN ROTOR MIPxFIP SCH. 40 PVC ELL (2) 6" 12" SCH. 80 PVC NIPPLE MIPxFIP SCH. 40 PVC 90 ELL SCH. 40 SLIPxFIPT PVC FITTING NOTE: DIAMETERS OF FITTINGS AND NIPPLES SHALL EQUAL ROTOR INLET DIAMETER SET ROTOR PERPENDICULAR TO FINISH GRADE HI-POPGEAR DRIVEN ROTOR 14 FITTINGS APPLY TEFLON TAPE ALL PVC MALE THREADED DEGREES 30-60 24" 3" SET BOTTOM OF CAP AT GRADE CURB & GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE POP-UP SPRAY HEAD 12" MALExBARB ELL 12" DIA. POLYETHYLENE SWING PIPE (4 L.F. MAXIMUM LENGTH) 12" MALExBARB ADAPTER NOTE: ·SET HEAD PERPENDICULAR TO FINISH GRADE. ·APPLY TEFLON TAPE TO MALE PVC THREADED FITTINGS. ·DOUBLE CLAMP 112" & 2" DIAMETER FITTINGS. PVC LATERAL SWING W/ LINE SIZEx12" SLIPxFIPT FITTING POP-UP SPRAY HEAD 11SWING PIPE - PVC SET HEAD PERPENDICULAR TO FINISH GRADE SET LIP AT FINISHED GRADE CURB AND GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE 6" GEAR DRIVEN ROTOR 12"x3 4" BARBxMALE ELL 12" DIA. POLYETHYLENE SWING PIPE (4 L.F. MAXIMUM LENGTH) 12" MALExBARB ADAPTER PVC LATERAL PIPING W/ LINE SIZEx12" SLIPxFIPT FITTING GEAR DRIVEN ROTOR 13SWING PIPE - PVC IRRIGATION DETAILS IR-105 Buck Point Ranch_Permit_Irrigation-CD's-rev.dwg Carbondale CO. 81623 | 970.963.6520 311 Main Street, Suite 102 ECOLOGICAL DESIGN LAND PLANNING & URBAN DESIGN LANDSCAPE ARCHITECTURE 21254.01Buck Point Ranch1708 CR 121, CarbondaleCO 81623PROJECT NO: PHASE BUILDING PERMIT APPLICATION ADDENDUM 08.12.2022 3 4" PVC BALL VALVE WITH 3 4" PVC INSxMIPT ADAPTER AND S.S. CLAMP 3 4" DRIP TUBING - COIL SUFFICIENT LENGTH IN BOX TO EXTEND HOSE ADAPTER OUTSIDE OF VALVE BOX. 3 4" WASHED RIVER ROCK SUMP (1 CU. FT.) INSERT TEE WITH CLAMPS 10" ROUND VALVE BOX WITH COVER - BRAND "DB" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. SECTIONPLAN DISTANCES VARY: CONTRACTOR SHALL LOCATE FLUSH VALVE BOX TO BE SCREENED BY PLANT MATERIAL AND ACCESSIBLE. OPERATIONAL INDICATOR SHALL BE LOCATED FOR EASY VISIBILITY DURING OPERATION PLANT MATERIAL INDICATOR HEAD PLANTER BED WALL OR EDGER FLUSH VALVE POLY PIPE FROM EXHAUST HEADER OR DRIP LATERAL FINISH GRADE DEFLECT TUBING TO PERMIT ENTRY THROUGH BOTTOM OF VALVE BOX. 12" POP-UP SPRAY HEAD WITH CHECK VALVE, CLOSED NOZZLE, & SWING PIPE (ZONE OPERATIONAL INDICATOR) DRIP FLUSH VALVE PLANT MATERIAL PLANT SIZE EMITTER FLOW RATE EMITTER QTY. AT MULCHED BED LOCATIONS EMITTER QTY. AT NATIVE SEED LOCATIONS 1 - 2 GALLON MATERIAL 0.5 GPH ONE EACH ONE EACH 5 GALLON MATERIAL 0.5 GPH TWO EACH TWO EACH 112" CALIPER TREE 1.0 GPH THREE EACH FOUR EACH 2" CALIPER TREE 1.0 GPH FOUR EACH SIX EACH 212" CALIPER TREE 1.0 GPH SIX EACH EIGHT EACH 3" CALIPER TREE 1.0 GPH EIGHT EACH TEN EACH 31 2" CALIPER TREE 1.0 GPH NINE EACH ELEVEN EACH 4" CALIPER TREE 1.0 GPH TEN EACH TWELVE EACH 6 FT. CONIFEROUS TREE 1.0 GPH FOUR EACH SIX EACH 8 FT. CONIFEROUS TREE 1.0 GPH SIX EACH NINE EACH 10 FT. CONIFEROUS TREE 1.0 GPH EIGHT EACH TWELVE EACH 12 FT. CONIFEROUS TREE 1.0 GPH TEN EACH FOURTEEN EACH NOTES: ·INSTALL EMITTERS ON OPPOSING SIDES OF ROOTBALL. THREE OR MORE EMITTERS SHALL BE EQUALLY SPACED AROUND ROOT BALL. ·EMITTERS ARE TO BE INSTALLED TO CLEAR SURFACE BY A MINIMUM OF 1" AND A MAXIMUM OF 2". ·FLUSH ALL LINES THOROUGHLY, INCLUDING EMITTER MICRO-TUBING PRIOR TO EMITTER INSTALLATION. ·IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL BOTH EMITTERS ON UPHILL SIDE OF ROOT BALL. ·EMITTERS SHALL BE SELF-FLUSHING, PRESSURE COMPENSATING-TYPE UNLESS NOTED OTHERWISE WITHIN TECHNICAL SPECIFICATIONS. ·DRIP VALVE ZONES ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT REQUIREMENTS (HYDROZONES) AND SUN EXPOSURE. ·CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN. ·SITE CONDITIONS MAY DICTATE THAT MULTIPLE SUN EXPOSURES ARE VALVED TOGETHER DURING THE DESIGN PROCESS. CONTRACTOR SHALL ADJUST EMITTER SCHEDULE AS FOLLOWS: ··EMITTER QUANTITIES SHALL REMAIN THE SAME BUT EMITTER GALLONAGES SHALL BE DOUBLED FOR PLANTS WITH SOUTH AND WEST EXPOSURES. ··EMITTER QUANTITIES AND GALLONAGE SHALL BE AS SHOWN IN SCHEDULE FOR PLANTS WITH NORTH AND EAST EXPOSURES. ··PLANTINGS WITH NORTH AND EAST EXPOSURE SHALL DICTATE VALVE RUN-TIMES AND CONTRACTOR SHALL ADJUST SCHEDULING ACCORDINGLY. DOWN 4:1(+)-SLOPE SECTION 10" MIN 4"-6" PLANTING BACKFILL MATERIAL POLY DRIP TUBING PLANT ROOTBALL EMITTER - STAKE TO EDGE OF ROOTBALL EMITTER MICRO-TUBING - 60" MAXIMUM LENGTH PLANT MATERIAL EMITTER - REFER TO SCHEDULE FOR EMITTER QUANTITY. REFER TO SPECIFICATIONS FOR MANUFACTURER AND MODEL NUMBER. MULCH LAYER EMITTER MICRO-TUBING POLY DRIP TUBING - RE: TECHNICAL SPECIFICATIONS 6" 10 GAUGE JUTE STAKE OR APPROVED EQUAL PLAN Know what's below. before you dig.Call R 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management 18 17DRIP EMITTER DIRECTORY IRRIGATION SCHEDULE IR-100 IRRIGATION NOTES IR-100 IRRIGATION PLANS IR-101 - IR-102 IRRIGATION DETAILS IR-103 - IR-105 IRRIGATION PUMP DETAILS IR-106 PLANT SIZE MINIMUM EMITTER QTY. PER TREE 5 GALLON SHRUBS THREE EACH 112" CALIPER TREE EIGHT EACH 2" CALIPER TREE TWELVE EACH 212" CALIPER TREE SIXTEEN EACH 3" CALIPER TREE TWENTY EACH 312" CALIPER TREE TWENTY-TWO EACH 4" CALIPER TREE TWENTY-FOUR EACH 6 FT. CONIFEROUS TREE TWELVE EACH 8 FT. CONIFEROUS TREE EIGHTEEN EACH 10 FT. CONIFEROUS TREE TWENTY-FOUR EACH 12 FT. CONIFEROUS TREE TWENTY-EIGHT EACH NOTES: ·EMITTERS SHALL BE EQUALLY SPACED AROUND ROOT BALL. ·EMITTER FLOW RATE PER SCHEDULE. ·DRIPLINE EMITTER SPACING PER SCHEDULE. EDGE OF EXCAVATION EMITTER DRIPLINE (BELOW MULCH AND FABRIC, AROUND THE ROOT BALL) 6'' FROM ROOTBALL LATERAL SUPPLY PIPE (WITH IN-LINE CHECK VALVES IF REQUIRED) POLY DRIP SUPPLY TUBING NO EMITTERS EMITTER DRIPLINE (BELOW MULCH AND FABRIC, AROUND THE ROOT BALL) 6'' FROM ROOTBALL PLANTING BACKFILL MATERIAL STAKE DRIP PIPE TO EDGE OF ROOTBALL ROOTBALL TRUNK SUBSURFACE EMITTER TREE RING 16 DECODER GROUNDING DETAIL 20 10" ROUND VALVE BCX WIRE CLAMP 3/4" CRUSHED GRAVEL 8 FT. COPPER GROUNDING ROD #6 BRAIDED COPER WIRE TO DECODER 3" RECTANGULAR VALVE BOX WITH CONTROL VALVE AND FINISH GRADE DECODER DECODER 8'-12' MINIMUM" SUMP (2 C.U. FT.) 3/4" PVC SUBGRADE SECURE DECODER TO PVC PIPE WITH NYLON WIRE TIE (2) 1" MIN. 12" MIN. DECODER, WIRE TIE (2) TO [" PVC PIPE TO STABILIZE IN VALVE BOX NOTE: USE DBR/Y-6 ON WIRE CONNECTIONS TO EARTH GROUND INSTALLED IN SEPARATE LOCATION PER ASIC GUIDELINES. 1 PER 12 DECODERS OR EVERY 1000 FT. AND AT EVERY END OF TWO WIRE PATH. BARE COPPER WIRE TO BE EXTENDED USING A CADWELD TO GROUND ROD. GROUND ROD TO BE LOCATED A MINIMUM OF 10 LINEAR FEET FROM VALVE BOX AND TWO WIRE PATH. WIRE PATH FROM CONTROLLER ALLOW 5 FT. SLACK PER DECODER. ALL WIRE TO BE TO 14 UAG STANDARDS. REFER TO TWO WIRE PLAN FOR CONTROLLER WIRE MANUFACTURE AND MODEL NUMBER. BLAZING WIRE CONNECTORS -BVS-2 DECODER (REFER TO SCHEDULE FOR MODEL NUMBER) ID WIRE PATH TO NEXT DECODER (3M) DBY (2) TWO-WIRE DECODER WIRING DIAGRAM 19 KASCO AERIATION SYSTEM -TYPICAL 21 ALL AERATION EQUIPMENT SHALL BE INSTALLED PER SUPPLIERS AND MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS. (KASCO MARINE, INC., 715-262-4486, WWW.KASCOMARINE.COM) P 731 4 731 6 731 8 73 2 0 731 2 A R 73 3 0 21 2'' 21 2 #8.0 #8.0 GAR 1'' 11 4'' IRRIGATION PUMP DETAILS IR-106 Buck Point Ranch_Permit_Irrigation-CD's-rev.dwg Carbondale CO. 81623 | 970.963.6520 311 Main Street, Suite 102 ECOLOGICAL DESIGN LAND PLANNING & URBAN DESIGN LANDSCAPE ARCHITECTURE 21254.01Buck Point Ranch1708 CR 121, CarbondaleCO 81623PROJECT NO: PHASE BUILDING PERMIT APPLICATION ADDENDUM 08.12.2022 Know what's below. before you dig.Call R 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management H) 2-POINT LEVEL CONTROL/SAFETY FOR WET WELL F) OWNER TRAINING PER SPECIFICATIONS. G) PRESSURE RELIEF VALVE A) VARIABLE FREQUENCY DRIVE WITH 5 HP PUMP (38 FLA @ 240V/1 PHASE). 1. Pumping System Notes B) PUMP PANEL AND CONTROLS PER SPECIFICATIONS. 240 VOLT, 1 PHASE POWER SUPPLY (APPROX. 73 FLA) C AUTOMATIC FILTER WITH 200 MICRON SCREEN, FLUSH ASSEMBLY (ISOLATION VALVE, ELECTRIC CONTROL VALVE) AND CHECK VALVE I) SELF-CLEANING SCREEN RETURN LINE ASSEMBLY SHALL CONSIST OF 1" BRONZE BALL VALVE, 1" BRONZE CHECK VALVE, 1" SOLENOID OPERATED ELECTRIC VALVE E) PHASE MONITOR D) VFD BY-PASS SWITCH J) PUMP STATION SHALL BE ACTIVATED VIA PRESSURE DROP AND DEACTIVATED VIA NO FLOW PRIMARY PUMP SHALL BE CAPABLE OF 100 GPM AT 85 PSI DISCHARGE PRESSURE (85 GPM FOR IRRIGATION, 15 GPM FOR FILTER) K) PRESSURE TANK L) HOA SWITCHES (FOR SYSTEM), ON-OFF SELECTOR SWITCHES (ONE PER PUMP), PUMP RUN LIGHTS (ONE PER EA. PUMP, LAKE SCREEN, FILTER) GENERAL FAULT LIGHT (RED) M) STATION DISCHARGE ISOLATION VALVE N) DISCHARGE PRESSURE GAUGE COMPACT SOIL TO 95% STANDARD PROCTER DENSITY TYPICAL FOR AROUND WET WELL AND UNDER CRUSHER FINE BASE. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES CONTRACTOR IS RESPONSIBLE FOR ALL CONNECTIONS BETWEEN ELECTRICAL SERVICE AND PUMPING SYSTEM 2. 3. 5. CONTRACTOR TO INSTALL A PRECISION PUMPING SYSTEM OR APPROVED EQUAL SINGLE SKID PUMPING STATION THE PUMP STATION SHALL MEET REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS, DETAILS AND SPECIFICATIONS. SUBMIT WITH BID. 6. ELECTRICAL PERMITS SHALL BE OBTAINED AND PAID BY CONTRACTOR. ELECTRICAL DRAWINGS REQUIRED FOR PERMITTING SHALL BE PREPARED AND SUBMITTED BY CONTRACTOR 7. 8. CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION AND INSTALLATION PIPING BETWEEN FINAL PUMP LOCATION AND IRRIGATION AND AUGMENTATION PIPE CONNECTIONS ANCHOR PUMPING SYSTEM CONCRETE PAD PER MANUFACTURERS RECOMMENDATIONS CONTRACTOR IS RESPONSIBLE FOR ALL ADDITIONAL EQUIPMENT FOR THE INSTALLATION OF THE PUMPING SYSTEM AND ENCLOSURE THAT IS NOT SUPPLIED BY PUMP MANUFACTURER 1. 4. AS DETAILED. EQUAL SUBMITTAL MUST BE A COMPLETE SET OF DRAWINGS AND LIST EQUIPMENT USED. PUMP STATION OFF-LOAD CRANE REQUIREMENTS BY CONTRACTOR 9. NOTES CONTRACTOR TO INSTALL PRECISION PUMPING SYSTEM: #S##US1005X0050-085V32X241ONS-2-SS SUBMERSIBLE (ENCLOSURE) PUMP STATION AS DETAILED. PUMP STATION SHALL PROVIDE 50 GPM AT DISCHARGE PRESSURE OF 85 PSI. PUMP STATION SHALL MEET REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS, DETAILS AND SPECIFICATIONS. REQUIREMENTS SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: CONTRACTOR IS RESPONSIBLE FOR ALL WORK AND EQUIPMENT REQUIRED FOR INSTALLATION OF BUT NOT LIMITED TO, PUMPING SYSTEM, ENCLOSURE, PIPING, WET WELL AND ELECTRICAL. ANY ADDITIONAL EQUIPMENT NOT SUPPLIED FROM MANUFACTURER FOR INSTALLATION OF ANY PRODUCT IS THE RESPONSIBILITY OF THE CONTRACTOR. REFER TO ALL MANUFACTURERS RECOMMENDATIONS FOR REQUIRED EQUIPMENT. INTAKE INV. LOW WATER SHUT-OFF BOTTOM OF WET-WELL (FLOOR) BOTTOM OF SUBMERSIABLE PUMP BOTTOM OF POND 7313.34 FT. P1 36'' PRECAST CONCRETE WET-WELL - RAM-NECK OR EQUAL ALL JOINTS PEA GRAVEL LEVELING COURSE - MINIMUM 12'' DEEP PUMP STATION AND WET WELL - SECTION NTS 8" HDPE DR-11 FUSED WET WELL INTAKE LINE FROM POND, WITH LINK SEAL APPROXIMATELY 140 FT. LONG BOTTOM OF WET WELL 7316.50 FT. 7315.00 FT. 7312.00 FT. 7313.00 FT. PUMP VAULT COVER (SET AT GRADE) PUMP VAULT (40"W x 63"L x 48"D) BELOW GRADE FILTER -SELF FLUSHING SUBMERSIBLE PUMP AND RISER PIPE PUMP DISCHARGE PIPE PUMP STATION POND INTAKE PIPING NTS DO NOT SLOPE INTAKE PIPE (PIPE INV. 7315.00 FT) POND BOTTOM ELEV. 7313 +/- FT. 1.5'' 100 PSI NSF POLYETHYLENE, SELF-CLEANING SCREEN RETURN LINE, SHOULD BE STRAPPED TO PVC PIPE ON 10' O.C. WHERE EXPOSED IN POND. INSTALL PIPE BOOT AS NEEDED. COORDINATE FINAL LOCATION WITH POND LINER. CONTROL WIRING FROM POWER PANEL TO BE LOCATED AT BUILDING. ALL WIRING FROM PANEL TO JUNCTION BOX TO BE INSTALLED IN CONDUIT, PER LOCAL CODES. 40 INCH WIDE 63 INCH LONG 6574.00 + FT. WSE 7325.00 FT. VAF1 - FINISH GRADE PUMP VAULT COVER, 3" ABOVE GRADE ELECTRIC CONTROL VALVE FOR INTAKE SCREEN - 1.5" PIPE TO INTAKE SCREEN SUBMERSIBLE PUMP AND RISER PIPE 3" PUMP DISCHARGE PIPE 7330.00 + FT.TOP OF WET WELL & LEVELING BASE ELECTRIC CONTROL VALVE FROM FILTER, PIPE BELOW GRADE AND DAY LIGHT. 4" FLOOR DRAIN, INTO WET WELL PUMP VAULT (36"W x 60"L x 48"D) BELOW GRADE 48 INCH DEEP PRESSURE TANK SELF FLUSHING FILTER 1" ELECTRIC CONTROL VALVE FOR INTAKE SCREEN - 1.5" POLY PIPE TO INTAKE SCREEN 1" ELECTRIC CONTROL VALVE FROM FILTER, 1.5" POLY x 3" PVC PIPE BELOW GRADE AND DAY LIGHT. SUBMERSIBLE PUMP AND RISER PIPE PRESSURE TANK CONTROL WIRING FROM POWER PANEL TO BE LOCATED AT BUILDING. ALL WIRING FROM PANEL TO JUNCTION BOX TO BE INSTALLED IN CONDUIT, PER LOCAL CODES. CONCRETE PAD 3 INCH AIR RELIEF VALVE 4" FLOOR DRAIN, INTO WET WELL PEA GRAVEL LEVELING COURSE - MINIMUM 12'' DEEP PEA GRAVEL LEVELING COURSE - MINIMUM 12'' DEEP COMPACT SOIL TO 95% STANDARD PROCTER DENSITY TYPICAL FOR AROUND WET WELL AND UNDER CRUSHER FINE BASE. PUMP ASSEMBLY WILL INCLUDE FIBERGLASS ENCLOSURE AND PUMP ASSEMBLY. REFER TO PUMP SYSTEMS NOTES NO.1, FOR MODEL NUMBER AND REQUIREMENTS. SECURE ENCLOSE TO WET WELL WITH ANCHOR BOLTS (4 REQUIRED). SECURE ENCLOSE TO WET WELL WITH ANCHOR BOLTS (4 REQUIRED). SAKRETE BAGS - QTY. AS REQUIRED P2 MINIMUM 6'' CLEARANCE FROM WATER LEVEL 24'' MINIMUM PUMP MANUFACTURER SUPPLIED CLEMONS CW-400 -6" SELF-CLEANING POND INTAKE SCREEN W/ 12 MESH SCREEN. PROVIDE WITH SEALED BEARINGS OR APPROVED EQUAL. 8'' HDPE x 6" PVC FLANGED CONNECTION 8" HDPE DR-11 FUSED INTAKE LINE 3" PVC FILTER DISCHARGE PIPE INSTALL MINIMUM 6'' ABOVE HIGH WATER LEVEL. COORDINATE WITH LANDSCAPE ARCHITECT AS TO CONNECT POLY PIPING TO SCREEN VIA INSERT FITTING & TWO STAINLESS STEEL WORM SCREW CLAMPS WSE 6571 + FT. 1.5'' POLY NSF 100 PSI PIPE FROM PUMP TO SELF-CLEANING POND INTAKE SCREEN. DISCHARGE PIPE LOCATION AND RIP-RAP BOULDER PLACEMENT AND REQUIREMENTS. NOTE: ANY PENETRATIONS THROUGH POND LINER SHALL BE PIPE BOOTED Scale 1'' = 10' REPAIR EXCAVATION AND POND LINER WITH SIMILAR MATERIALS AS ORIGINAL CONDITION OF POND 120V / 240V ELECTRICAL CONTROL PANEL (FURNISHED WITH PUMP ASSEMBLY), TO BE INSTALLED BY OTHERS (TBC). ALL REQUIRED POWER & CONTROL WIRES FROM CONTROL PANEL TO PUMP VAULT JUNCTION BOX (PER LOCAL CODES). ELECTRICAL PERMITS AND DRAWINGS ARE REQUIRED BY THE CONTRACTOR. 2.5" PVC MAINLINE 74 +/-FT. DIRECTORY IRRIGATION SCHEDULE IR-100 IRRIGATION NOTES IR-100 IRRIGATION PLANS IR-101 - IR-102 IRRIGATION DETAILS IR-103 - IR-105 IRRIGATION PUMP DETAILS IR-106 (REDUCE TO 2" PVC MAINLINE) AUTOMATIC LAKE INTAKE SCREEN AND CONCRETE SUPPORT STRUCTURE 1.5'' POLY NSF 100 PSI PIPE FROM PUMP TO AUTOMATIC LAKE SCREEN. 3'' CL200 PVC AUTOMATIC FILTER DISCHARGE PIPE. DAYLIGHT ABOVE WATER EDGE AND INSTALL 3' RIP-RAP TO 6" MIN. HEIGHT ABOVE WATER LEVEL. RIP-RAP BOULDER DISCHARGE BASIN: PUMP VAULT LOCATION AND WET WELL LOCATION 120V / 240V -SINGLE PHASE ELECTRICAL CONTROL PANEL (FURNISHED WITH PUMP ASSEMBLY), TO BE INSTALLED BY STRUCTURE TO THE EAST OF PUMP LOCATION (APPROX. 48'). INSTALL PVC CONDUIT(S) AND ALL REQUIRED POWER & CONTROL WIRES FROM CONTROL PANEL TO PUMP VAULT JUNCTION BOX (PER LOCAL CODES). ELECTRICAL PERMITS AND DRAWINGS ARE REQUIRED BY THE CONTRACTOR. 1.5" POLY PIPE FROM AUTOMATIC FILTER TO BE EXTENDED OUT OF PUMP VAULT, AND TRANSITION TO 3'' CL200 PVC DISCHARGE PIPE. 1.5" POLY PIPE FROM 1" ELECTRIC CONTROL VALVE OUT OF PUMP VAULT, TO INTAKE SELF FLUSHING SCREEN. 3" PVC FILTER DISCHARGE PIPE INSTALL MINIMUM 6'' ABOVE HIGH WATER LEVEL. COORDINATE WITH LANDSCAPE ARCHITECT AS TO DISCHARGE PIPE LOCATION AND RIP-RAP BOULDER PLACEMENT AND REQUIREMENTS. 8" HDPE DR11 FUSED WET WELL INTAKE LINE FROM POND ENLARGEMENT OF PUMP STATION EP1