Loading...
HomeMy WebLinkAboutGCPH Final Acceptance Letter 03.10.2023Garfield County Public Health Department – working to promote health and prevent disease   Public Health James M. “Mike” Chmura  12750 Highway 82  Carbondale, CO 81623  Via email: mike@korultd.com      Subject: Final Acceptance Letter    12750 Highway 82  Carbondale, CO 81623  OWTS Permit #: SEPT‐7506      March 10, 2023      Mike,    Due to unforeseen circumstances, Garfield County Public Health was unable to visit the  site of the residence at 12750 Highway 82 near Carbondale in Garfield County, Colorado to  observe the OWTS installation pursuant to OWTS Permit # SEPT‐7506. The designer provided  new plans for the system on September 7, 2022. However, the OWTS permit issued by GCPH  was not revised at the time. This letter documents GCPH approval of the installed components.     GCPH was able to speak with the designer of the system, who observed multiple stages  of the installation and provided an observation letter to us dated February 14, 2023. According  to the letter, the contractor had installed the new poly 1,500‐gallon two‐compartment septic  tank (to allow a total of 5 bedrooms to connect to the tank)  with an effluent filter in the outlet  tee of the tank followed by a 500‐gallon pump chamber with a high‐head pump in the chamber,  the pump line, the Automatic Distributing Valve (ADV), and three unlined sand filter bed Soil  Treatment Areas (STAs). The STAs were each 77’ x 44.5’ (total of 934.54 ft2 of STA) and each  STA bed consists of two laterals with 5/32” orifices facing down at 3’ spacing. Orifice shields  were installed under each orifice on the laterals. The laterals were encased in GeoMat filter  fabric distribution media placed directly on the sand filter material. The new tank and ADV were  installed level with access to grade. The ADV was installed at the high point of the OWTS. The  laterals ended in an upward‐facing 90‐degree ell with a ball valve to allow flushing of the  laterals. Inspection ports were provided at each corner of each bed. Additionally, we were  provided with a start‐up latter of the pump and system by Valley Precast, which indicated the  pump was started properly, and the system went through several cycles without issues. In our  195 W. 14th Street  Rifle, CO 81650  (970) 625‐5200 2014 Blake Avenue  Glenwood Springs, CO 81601  (970) 945‐6614  Garfield County Public Health Department – working to promote health and prevent disease   opinion, this system was installed in general conformance with Garfield County OWTS  Regulations. Please submit an As‐built drawing of the system when available. No further action  or review from Garfield County Environmental Health is required regarding this permit.      Thank you,      Edward R. “Ted” White, P.E.   Environmental Health Specialist III  Garfield County Public Health  2014 Blake Avenue  Glenwood Springs, CO 81601  (970) 945‐6614 ext. 8106  twhite@garfield‐county.com