Loading...
HomeMy WebLinkAboutConditions of PermitCOND ITIONS OF PERMI T BLRE-O3-23-801ó Stephen & Swanny Harkins New S/F Dwelling w/ Attached Garâ9e, Deck & Patio, Porte Cochere & 3,4ó3 sq ft Unfinished Basement 17 43 H ig h Aspen Dr. GWS High Aspen Ranch, Lot 20 $ 1) ALL WORK SHALL COMply W|TH THE 201s INTERNATTONAL RESIDENTIAL CODE (l.R.C.)AND 2009 I NTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL pERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION A CCRT ICRTE OF OCCUPANCY. 4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. 5) OPEN-HOLE SOTLS REPORT REOUTRED AT FOOTTNG TNSPECTION. 2.000 PSF SOIL BEARING CAPACIry. SITE ELEVATION > 8,OOO FT - MIN 42 INCH FROST DEPTH. ó) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR INSPECTOR AT TIME OF FRAME INSPECTION. 7) ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS)TO BE INSPECTED BYA PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO. PROVIDE ENGINEER'S FINAL REPORT TO GARFIELD COUNTY ENVIRONMENTAL HEALTH PRIOR TO FINAL BUILDING INSPECTION & CERTI FICATE OF OCCUPANCY. 8) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSIONAL LICENSED SURVEYOR, lS REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS-BUILT ROOFS COMPLY WITH GARFELD COUNry'S 25-FOOT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE. 9) SECONDARY DWELLTNG SHOWN ON THE S|TE PLAN rS NOI PART OF THIS PERMIT SCOPE. FUTURE BUILDING TO BE REMITTED UNDER A SEPARATE PERMIT AND IN ACCORDANCE WITH LAND USE AND BUILDING CODES IN EFFECT AT TIME OF FUTURE WORK. 10) LOWER LEVEL FLOOR PLAN APPROVED W|TH STAIRWELL, 197 SO FT MECHANICAL STORAGE AND FULLY UNFINISHED BASEMENT. IF ANY FUTURE UNDERGROUND DWV / WATER / GAS PIPING IS ROUGHED IN, WORK SHALL BE STUBBED OUT i CAPPED WITH NO FINISHED FIXTURES ATTACHED. FUTURE BASEMENT FINISH REOURES SUBMISSION, TO GARFIELD COUNry COMMUNIry DEVELOPMENT, OF A NEW BUILDING APPLICATION -- INCLUDING EXISTING / PROPOSED LOWER LËVEL FLOOR PLAN DETAILS -- IN ACCORDANCE WITH ADOPTED BUILDING CODES AND LAND USE REGULATIONS IN EFFECT AT TIME OF FUTURE WORK. 1 1 ) BUtLDtNG STRUCTURE CONTATNS A S|GNTFTCANT AMOUNT OF STEEL FRAMING. ALL HIGH STRENGTH BOLTING AND FIELD WELDING REOUIRES SPECIAL INSPECTOR. PROVIDE APPROVAL REPORT AT FRAMING INSPECTION. IT SHALL BE AT GARFIELD COUNTY BUILDING INSPECTOR'S DISCRETION - BASED ON OBSERVED SITE CONDITIONS - TO REOUIRE FURTHER APPROVALS BY EITHER THE ENGINEER OF RECORD OR A SPECIAL INSPECTOR.