Loading...
HomeMy WebLinkAboutObservation of Excavation 04.11.2023lGrtffii,[mmifü'-" An EmÞloycc Ournsd Compony 5020 Gounty Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945.8454 email: kaglenwood@kumarusa.com www.kumarusa.com O'ffice Locations: Denver (HQ), Parker, Colorado Spings, Fort Cdlins, Glenvrcod Søtngs, and Summit C.;q¡nty, Colorado April 11,2023 Mark Bunchman 2859 County Road 335 New Castle, Colorado 81647 mbunchman@grnail.com Project No.23-7-231 Subject:Observation of Excavation, ProposedGaragelShop Building, 2859 County Road 335, Garfield County, Colorado Dear Mark: As requested, a representative of Kumar & Associates observed the excavation at the subject site on April 7,2023, to evaluate the soils exposed for foundation support. The findings of our observations and recommendations are presented in this report. The services were performed in accordance with our agreement for professional engineering services to you dated April 5,2023. The garagelshop building will be a single-story structure detached from the main residence. The building has been designed to be supported on a thickened slab foundation assuming an allowable soil bearing pressure of 1,500 psf by the structural engineer. At the time of our site visit, the foundation excavation had been cut in one level up to about 2 feet below the adjacent ground surface and daylighting to the northwest. The soils exposed in the bottom of the excavation consisted of stiff, sandy siþ clay. Results of swell-consolidation testing performed on samples taken from the site, shown on Figure 1, indicate the soils are moderately compressible under conditions of loading and wetting. No groundwater was encountered in the excavation and the soils were generally moist. Considering the conditions exposed in the excavation and the nature of the proposed constructiono a thickened slab foundation placed on the undisturbed natural soils designed for an allowable bearing pressure of 1,500 psf can be used for support of the proposed building. The exposed soils may tend to compress some when wetted and there could be some post- ¿onstruction settlement of the foundation if the bearing soils become wet. Precautions should be taken to prevent wetting of the bearing soils. A reduced frost cover for the foundation should be feasible provided ground insulation for the foundation is provided and some risk of frost heave is Mark Bunchman April 11,2023 Page2 acceptable. Prior to the foundation construction, all loose disturbed soils should be removed, and the subgrade compacted. The foundation should be well reinforced with both longitudinal and transverse steel to reduce the effects of some settlement or heave. Structural fill placed below the slab can consist of the on-site soils compacted to at least 95% of standard Proctor density (SPD) at a moisture content near optimum. Backfill placed around the structure should be compacted to at least 90% SPD and the surface graded to prevent ponding within at least 10 feet of the building. Landscape that requires regular heavy irrigation, such as sod, and sprinkler heads should not be located within 5 feet of the foundation. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the excavation have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. If you have any questions or need further assistance, please call our ofñce. Sincerely, Kumar & AssoeÍate$" Inc. David A. Young, P.E. DAY/ljf Attachment Figure l, Swell-Consolidation Test Results Kumar & Associates, lnc. É Project No.23"7.231 SAMPLE OF: Sondy Silly Cloy FROM: Bottom of NE Footing Pod Excqvotion WC = 18.7 96, DD = 93 pcf l ADDITIONAL COMPRESSION UNDER CONSTANT PRESSURE DUE TO WETTING 2 o\ JJt¡l =vl I zotr ô Jotnzo() o -2 -4 -6 -8 -10 I 23-7-231 Kumar & Associates SWELL-CONSOLIDATION TEST RESULTS 1Fig. E l! I j