Loading...
HomeMy WebLinkAboutHigh Strength Bolt Inspection Report 1.11.2023z Tom Doogan Peak 3 Construction 310 Market St. 1st Floor Basalt, CO. 81621 Re: 1065 Hidden Valley Dr. Dear Mr. Doogan, Date: 1-11-2023 Permit#: BLPE-06-22-7625 As requested, structural steel special inspection was conducted per the IBC 2015 Edition - Chapter 17: Structural Tests and Special Inspection and the City of Glenwood Springs requirements. I arrived on -site at 9:00 AM. I met with Mr. Patrick Owens with Mountain and Valley Iron in Grand Junction, CO. to review project requirements and material ready for inspection. I reviewed the welding procedure and the welder certifications and found them to be acceptable. Copies are kept of file with Jason Pluhar at Mountain and Valley Iron. Continuous visual welding inspection was conducted on the 2 of the 4 bent beam frames at the front of the residence according to the on -site drawings supplied by DB Structural Design. I observed the Complete Joint Penetration (CJP) groove welds at the top of the bent beams. Mr. Patrick Owens was the certified welder of record. All fit -up and preheat were checked prior to welding. The following parameters were observed to be compliant with the requirements of the governing WPS: • Base metal composition • Filler metal composition • Joint configuration and base metal preparation Monument Steel Inspection, LLC PO Box 23388 Glade Park, CO 81523 318.469.2279 monumentsteelinspectionllc22@gmail.com • Shielding gas and flow rate • Joint fit -up • Root opening • Preheat temperature • Interpass temperature • Welding current characteristics • Amperage employed • Voltage employed Upon completion, all CJP groove welds were observed to be compliant with project specifications and the visual inspection requirements as stated in Clause 8 of the AWS D1.1 Structural Welding Code — Steel: 2020 Edition. Continued inspection will conducted at a later date. Respectfully submitted, Dan 44z' 1�tk -ricker, CWI AWS CWI #09052051 Monument Steel Inspection Monument Steel Inspection, LLC 318.469.2279 PO Box 23388 Glade Park, CO 81523 monumentsteelinspectionlic22@gmail.com Monument Steel Inspection, LLC. Welding, Mechanical Fastenin, and Industrial Adhesive Inspection. P.O. Box 23388 Glade Park, CO. 81523 Phone: 318-469-2279 Email — monumentsteelinspectionllc22 ,gmail.com TO: Tom Doogan Peak 3 Construction 310 Market St. 1st Floor Basalt, CO 81621 Field inspection for 1065 Hidden Valley Dr. 1-11-2023 QUANTITY DESCRIPTION 10 hrs Travel and inspection time 1 hr I Report time 219 miles Mileage chg. INVOICE Invoice #: 247 Date: 1-13-2023 UNIT PRICE TOTAL $82.00/hr $820.00 $82.00/hr $82.00 $0.655/mi $143.45 T TOTAL DUE ON RECEIPT OF INVOICE $1045.45 Make all checks payable to Monument Steel Inspection, LLC. If you have any questions concerning this invoice, contact Daniel Bricker, 318-469-2279. Late fees totaling 5% will be accrued after 30 days of non-payment. Additional fees may result after 60 days of non-payment. THANK YOU FOR YOUR BUSINESS!