HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 1831 CR 114, Glenwood Springs, CO 81601 Parcel No.: _239308400010
Owner Name: Linda Hayes Owner Phone: (970) 379‐4576
Designed By: CBO Septic Consulting, Inc. Designer Phone: (970) 309‐5259
Contractor: Troy Trulove Contractor Phone: (970) 309‐4446
Number of Bedrooms: _5_ Minimum Tank Capacity: 1,500‐gallon Minimum Absorption: 945 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐7023 Extended_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _08/17/2021____________________ Expiration Date_10/18/2023_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO Septic Consulting, Inc. dated March 6, 2020. Changes to the design and permit
must be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve an existing three‐bedroom residence, with the potential for a 1‐bedroom
addition and a 1‐bedroom ADU. Two existing OWTSs on the property will be abandoned and
replaced with a new OWTS. The new system will consist of a new, two‐compartment 1,500‐gallon
septic tank set level with access to grade and an effluent filter in the outlet tee of the tank. Effluent
will gravity flow to a distribution box set level with access to grade that will distribute effluent to 960
ft2 of STA. The new STA will consist of five gravelless chamber trenches, each trench consisting of 16
Infiltrator Quick4 chambers per trench (80 chambers total). Inspection ports are to be installed at
each end of each trench. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
04/18/2022
Issued By: Garfield County Environmental Health
Department
Date