HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-04-23-8048
Scott & Heidi Young
New SlF Dwelling w/ attached garage
982 CR 245, S¡lt
Greene Subdivision Exemptio n, LoT 2
1) ALL WORK SHALL COMpLY W|TH THE 2015 INTERNATTONAL RESIDENTIAL CODE (l.R.C.)
AND 2009 TNTERNATTONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACH ED "GARFI ELD COU NTY BU I LDI NG REOU I REM ENTS". N U M BER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRTC BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND IN
ACCORDANCE WITH SUBDIVISION EXEMPTION RECORDED PLAT NOTE #3. PLEASE REFER
TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR MORE
INFORMATION.
s) opEN-HoLE SOTLS REPORT MUST BE PREPARED BY THE GEOTECHNTCAL ENGINEER OF
RECORD. 2,500 PSF SOIL BEARING CAPACITY. GEOTECHNICAL ENGINEER MUST BE ON
PREMISES THROUGHOUT DRIVEN PILE INSTALLATION AND PROVIDE PILE INSTALLATION
REPORT FOR BUILDING FILE RECORDS. COMPACTION REPORT IS REOUIRED FOR ANY
COMPACTED STRUCTURAL FILL (SEE SLABS).
¿) pRE-ENctNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR TNSPECTOR AT TIME OF
FRAME INSPECTION.
7) HtcH STRENGTH BOLTTNG AND FTELD WELDTNG REOUIRES SPECTAL TNSPECTOR. lT SHALL
BE AT GARFIELD COUNTY BUILDING INSPECTOR'S DISCRETION, BASED ON OBSERVED
INSTALLATIONS AND SITE CONDITIONS .- TO REOUIRE SUCH SPECIAL REPORT AT
FRAMING INSPECTION.
8) SEPTIC SYSTEM REVIEW / APPROVAL: PRIOR TO FINAL BUILDING INSPECTION &
CERTIFICATE OCCUPANCY PROVIDE FINAL APPROVAL / SIGN -OFF FROM GARFIELD
COUNry'S PUBLIC HEALTH DEPT.