Loading...
HomeMy WebLinkAboutPermit  Garfield County Public Health  2014 Blake Ave.   Glenwood Springs, CO 81601  Phone: (970) 945‐6614 ext. 8150  For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable   Project Address: 3711 Grass Mesa Road, Rifle, CO    Parcel No.: _217734300387  Owner Name: KJS Revocable Living Trust   Owner Phone: (702) 340‐5222  Designed By: Sopris Engineering, LLC    Designer Phone: (970) 704‐0311  Number of Bedrooms:  1   Minimum Tank Capacity: 1,000‐gallon  Minimum Absorption: 300 ft2    OWTS PERMIT   KEEP AVAILABLE AT PROJECT SITE   Permit Number _SEPT‐8059_______________________________  Permit Type X New X Repair X Remodel/addition X Tank only   Issue Date _05/08/2023____________________ Expiration Date_05/08/2024_________________   Permit Conditions:   Permit Conditions: This OWTS Permit is approved on the condition of compliance with the design as  submitted by Sopris Engineering, LLC dated October 6, 2022. Changes must be approved by Garfield  County Public Health and the designer prior to construction.     The new OWTS will serve a new 1‐bedroom tiny home (<400ft2). The system will consist of a new,  two‐compartment minimum 1,000‐gallon septic tank set level with access to grade and an effluent  filter in the outlet tee of the tank. Effluent will gravity flow to a distribution box set level with access  to grade that will distribute effluent to 312 ft2 of STA. The new STA will consist of 2 gravelless  chamber trenches with 13 Quick4 chambers per trench, for a total of 26 Quick4 chambers.  Inspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations  as designed.   Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final  inspection of the installed system prior to backfill.      Agreement   All installations must comply with all requirements of the Garfield County OWTS regulations  including but not limited to the conditions specified above.   In consideration of the issuance of the permit, the applicant hereby agrees to comply with all  laws and regulations related to the zoning, location, construction, and erection of the proposed  OWTS and associated structures for which this permit is granted. The applicant further agrees  that if the above said regulations are not fully complied with in the zoning, location, erection,  and construction of the above described OWTS and structure, the permit may then be revoked  by notice from the Health Department and immediately become null and void.  The issuance of a permit and specifications of terms and conditions therein will not constitute  assumption of liability, nor create presumption that the local public health agency or its  employees may be liable for the failure or malfunctioning of any system. Permit issuance will  not constitute a certification that the system, the equipment used in the system, or any  component used for system operation will ensure continuous compliance with the provision of  the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.   Permit Approval  Plans and specifications for the proposed OWTS have been reviewed and are considered  satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated  in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from  the date of issuance unless construction on the system has commenced. An "as‐built" drawing  must be submitted and inspection of the system must be completed by GCPH before final  approval of the system will be issued.        05/08/2023  Issued By: Garfield County Environmental Health  Department  Date