Loading...
HomeMy WebLinkAboutEngineer's Framing Letter 05.04.202316-00-00 B1 B2 1 Total Horizontal Product Length = 16-00-00 1 Page 1 of 2 Single 11-7/8"BCI®60-2.0 DF J01 (Joist) BC CALC®Member Report Dry |1 span |No cant.|16"OCS |Repetitive |Glued &nailed May 4,2023 11:28:21 Build 8545 Job name:FINNBAR File name: Address:28 FINNBAR Description: City,State,Zip:CARBONDALE,CO,81623 Specifier: Customer:Designer:LD Burgess Code reports:ESR-1336 Company:Boise Grand Junction Page 1 of 2 Reaction Summary (Down /Uplift)(lbs)Bearing Live Dead Snow Wind Roof Live B1,2"427 /0 160 /0 B2,2"427 /0 160 /0 Load Summary Live Dead Snow Wind Roof Live OCS Tag Description Load Type Ref.Start End Loc.100%90%115%160%125% 1 Standard Load Unf.Area (lb/ft²)L 00-00-00 16-00-00 Top 40 15 16" Controls Summary Value %Allowable Duration Case Location Pos.Moment 2286 ft-lbs 36.7%100%1 07-11-15 End Reaction 587 lbs 47.4%100%1 00-00-00 End Shear 574 lbs 34.3%100%1 00-02-00 Total Load Deflection L/829 (0.229")29.0%n\a 1 07-11-15 Live Load Deflection L/1140 (0.166")42.1%n\a 2 07-11-15 Max Defl.0.229"22.9%n\a 1 07-11-15 Span /Depth 16.0 Notch Repair #1 Reinforcement Required Notch Summary Center Ref.Flange Type Depth Length N01 03-00-00 L Top Side 1"2" Bearing Supports Dim.(LxW)Value %Allow Support %Allow Member Material B1 Hanger 2"x 2-5/16"587 lbs n\a 47.4%Hanger B2 Hanger 2"x 2-5/16"587 lbs n\a 47.4%Hanger BC FloorValue®Summary BC FloorValue®:Subfloor:3/4"OSB,Glue +Nail Minimum Enhanced Premium Subfloor Rating:Premium Controlling Location:08-00-00 Cautions Hanger model Hanger was not found.Hanger has not been analyzed for adequate capacity. Notes Design meets Code minimum (L/240)Total load deflection criteria. Design meets User specified (L/480)Live load deflection criteria. Design meets arbitrary (1")Maximum Total load deflection criteria. Composite EI value based on 3/4"thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. BC CALC®analysis is based on IBC 2009. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy,prior to anyone relying on such output as evidence of suitability for a particular application.The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call (800)232-0788 before installation. BC CALC®,BC FRAMER®,AJS™, ALLJOIST®,BC RIM BOARD™,BCI®, BOISE GLULAM™,BC FloorValue®, VERSA-LAM®,VERSA-RIM PLUS®, Page 2 of 2 Single 11-7/8"BCI®60-2.0 DF J01 (Joist) BC CALC®Member Report Dry |1 span |No cant.|16"OCS |Repetitive |Glued &nailed May 4,2023 11:28:21 Build 8545 Job name:FINNBAR File name: Address:28 FINNBAR Description: City,State,Zip:CARBONDALE,CO,81623 Specifier: Customer:Designer:LD Burgess Code reports:ESR-1336 Company:Boise Grand Junction Page 2 of 2 Repair Details:Flange Notches NOTE:This repair is valid only for the Boise Cascade product listed above per the design information listed,and applicable to one member only.This is only applicable to one notch and any additonal notches require additional review.The project’s design professional of record is responsible for validating that all design information listed complies with the corresponding requirements in the structural plans and by the actual end use of the component. Notch Tag:1 Location:03-00-00 a =2" b =6" c =1" Installation Notes 1)Apply construction adhesive to cover all contact surfaces. 2)Install reinforcement tight to underside of top flange. 3)Nail reinforcement with 2 rows 0.128"x 3"(10d box)Nails,clinched,or 2 rows #8 x 2-1/2"wood screws @ 6"o.c. 4)Center reinforcement about center of flange notch.