HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-04.23.8078
MICHAEL & JESSICA RICE
SINGLE-FAMILY DWELLING WITH ATTACHED GARAGE
1340 Hidden Valley Dr, GWS
SPRINGRIDGE RESERVE, PH. 1, LOT 45
1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATTONAL RESTDENTTAL CODE (l.R.C.)
AND 2OO9 INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE |TEMS CONTAINED lN THE
ATTACH ED "GARFI ELD COUNTY BUI LDI NG REOU I REM ENTS". NU M BER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLYWITH WILDFIRE
MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE
FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY
COMMU NITY DEVELOPM ENT WEBSITE FOR ADDITIONAL I NFORMATION.
s) tN AccoRDANCE WITH RECORDED PLAT NOTE #ó - THE GENERAL CONTRACTOR
PROPOSES FIRE WALL ALTERNATE ASSEMBLY DETAIL(S) IN LIEU OF INSTALLING A FIRE-
SPRINKLER SYSTEM. SEE ALL ATTACHMENTS STAPLED TO THE FIELD / OFFICE COPY.
¿) opEN HOLE SOTLS REPORT rS REOUTRED AT FOOTING TNSPECTION AS PREPARED BY
GEOTECHNICAL ENGINEER. 1,500 PSF SOIL BEARING. COMPACTION REPORT BY
GEOTECHNICAL ENGINEER SHALL FURTHER ADDRESS ANY STRUCTURAL FILL.
Fire Arca Sepqratiqn Wall:
ln lìeu of the Fire Sprínkler Systern requirement, a "Fíre EorrÍer" moy be used to sepsrate
or comportmentalÍze the buildíng Ínto smaller sÍzed fke areos (2075 t,8.C., SectÍon 7O7).
SpecÍfic requírements Ínclude the following:
A, Z-Hour Fire-Rated Assemblv - The fìre barrier must comply wíth a Z-hour rated
assembly os approved by a recognized lístíng ogency' ìncludÍng {2) Ioyers af 5/8"
Type X drywallot both sìdes af wood-frame wolls (1.8.C., Tøble 707,3.fiJ.
B, Continuìtv - The fìre barrìer sholl extend from top of foundotion up to bottom of
roof sheøthing. Except as noted below for penetrotions, the 2'hourfire-rating ot
the fire borrier shall not be compromísed over its ent¡re length and height,
C. Penet$tìe¡t throueh Fire garrler - Ðoors ond door assemblìes locoted ín the
fire borríer, shøll provide o 96mÍnute fìre røting with automqtìc closìng devíce.
Mechsnìcal ductwork penetrotìng the fìre borrìer shall be protected by fìre-rated
dompers instçlled ìn such mønner as to ollow for regulør inspectÍons, servíce &
maíntenønce.