Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-04.23.8078 MICHAEL & JESSICA RICE SINGLE-FAMILY DWELLING WITH ATTACHED GARAGE 1340 Hidden Valley Dr, GWS SPRINGRIDGE RESERVE, PH. 1, LOT 45 1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATTONAL RESTDENTTAL CODE (l.R.C.) AND 2OO9 INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE |TEMS CONTAINED lN THE ATTACH ED "GARFI ELD COUNTY BUI LDI NG REOU I REM ENTS". NU M BER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL pERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLYWITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMU NITY DEVELOPM ENT WEBSITE FOR ADDITIONAL I NFORMATION. s) tN AccoRDANCE WITH RECORDED PLAT NOTE #ó - THE GENERAL CONTRACTOR PROPOSES FIRE WALL ALTERNATE ASSEMBLY DETAIL(S) IN LIEU OF INSTALLING A FIRE- SPRINKLER SYSTEM. SEE ALL ATTACHMENTS STAPLED TO THE FIELD / OFFICE COPY. ¿) opEN HOLE SOTLS REPORT rS REOUTRED AT FOOTING TNSPECTION AS PREPARED BY GEOTECHNICAL ENGINEER. 1,500 PSF SOIL BEARING. COMPACTION REPORT BY GEOTECHNICAL ENGINEER SHALL FURTHER ADDRESS ANY STRUCTURAL FILL. Fire Arca Sepqratiqn Wall: ln lìeu of the Fire Sprínkler Systern requirement, a "Fíre EorrÍer" moy be used to sepsrate or comportmentalÍze the buildíng Ínto smaller sÍzed fke areos (2075 t,8.C., SectÍon 7O7). SpecÍfic requírements Ínclude the following: A, Z-Hour Fire-Rated Assemblv - The fìre barrier must comply wíth a Z-hour rated assembly os approved by a recognized lístíng ogency' ìncludÍng {2) Ioyers af 5/8" Type X drywallot both sìdes af wood-frame wolls (1.8.C., Tøble 707,3.fiJ. B, Continuìtv - The fìre barrìer sholl extend from top of foundotion up to bottom of roof sheøthing. Except as noted below for penetrotions, the 2'hourfire-rating ot the fire borrier shall not be compromísed over its ent¡re length and height, C. Penet$tìe¡t throueh Fire garrler - Ðoors ond door assemblìes locoted ín the fire borríer, shøll provide o 96mÍnute fìre røting with automqtìc closìng devíce. Mechsnìcal ductwork penetrotìng the fìre borrìer shall be protected by fìre-rated dompers instçlled ìn such mønner as to ollow for regulør inspectÍons, servíce & maíntenønce.