HomeMy WebLinkAboutThird Party Welding Inspection Report-03.14.22West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 f{eport #1 Fage I of 1 Inspection Re port Dates: 3-14-22, 3-16-22, and 3-21-22 Project: Pestotnik Residence Lot 20 Ranch @ coulter c¡eek Address: 133 Saddle Cir. Carbondale, CO Building Permit No: BLRE -Ag-Zt-7A97 General Confractor: Dave Cardiff Const. Contractor that Perforrned Wonåc: Sopris Steel Ins n of sho fabrication 0r fieÍd wonh at ob site: Sho Report: V y inspected complete joint penetration shop welding in process at the apex of the bent beams pi ece marked 98l, 1081, and 1181. Above inspections included verification of welderr qualifications/w.p.s., use of proper welding electrodes/materials, inspection of the joint preparation, root pass welds, random observations of the intermediate weld pass layers, and a finalinspection of the completed welds. The shop welding inspected above appeared to be in substantial confonnance with the shop plans & the quality requirements of the AWS Dl.1 Structural Welding Code. Inspector/Technician ; Douglas E young ! Sr'e,.:i ,3¡$oåtíng S llaspeaÉon l'rpray-apruüierf f;ire¡iroal{illg åarspecfoa. n åy;'$s?*,',r, ?æs7ü7-4//b