HomeMy WebLinkAboutPermit Card
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 4190 County Road 103, Carbondale, CO 81623
Parcel No.: 239118200034
Owner Name: Christopher Morrow Owner Phone: (970) 379‐8089
Number of Bedrooms _2__Minimum Tank Capacity _1,000‐gal__Minimum Absorption_
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐8157________________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 06/21/2023 Expiration Date 06/21/2024
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by
Christopher Morrow on June 9, 2023. Changes must be approved by Garfield County Public Health
prior to construction.
This permit allows a new connection to an existing OWTS located at the property. Proposed
construction is a 1‐bedroom Accessory Dwelling Unit (ADU) with an attached garage. The existing
structure on the site consists of a 1‐bedroom A‐frame structure. Garfield County OWTS records
indicate the existing system was designed to accommodate 3‐bedrooms and consists of a two‐
compartment 1,500‐gallon septic tank and 525 ft2 of STA. The STA consists of two trenches of twelve
15 ft2 chambers and one trench of eleven 15 ft2 chambers. Maintain all setbacks and elevations as
designed. The existing system appears to have the capacity to handle the addition of the new ADU.
An inspection of the existing OWTS will be required to ensure that the system is in good working
order prior to Garfield County Public Health issuing a final acceptance letter for the new connection.
Contact Garfield County Public Health at least 48 hours prior to requesting final inspection of the
installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
06/21/2023
Issued By: Garfield County Environmental Health
Department
Date