Loading...
HomeMy WebLinkAboutObservation of Excavation 06.15.20232789 Ri�rside Parkway Client: Kay Crook Huddleston -Berry Grand Junction, co, e150PO Box 1174 i (970)255-8005 Rifle Engineering &r Teyling, LLC mtnahwloi, ronnerrwmi CO 81650 SOIL OBSERVATION REPORT Project: Parcel 217902400549 Approval Project Number: 02375 - 0001 Technician: Miriam Sanchez teviewed by: .le L eras Work Order No: 3bservation Date: June 15, 2023 Review Date: June 26, 2023 Geotechnical Report Title: Geotechnical Investigation Geotechnical Report Author: HBET Geotechnical Report No & Date: 02375-0001 12/16/2021 Geotechnical Report Bearing Capacity, psf: 2000PSF Development or Lot Specific Report: Lot Specific Sub -Contractor: Ow ner On Site Notification: Ben Crooks Foundation Type: Footing / Stem Wall Proof -roll equipment: Excavation Limits, ft: by Soil Type Observed: Native HItauge & Date of Calibration: 80082 9/9/22 E i�—JJ roposed Type of Structural Fill for Next Lift: NA c `o � Density Counts: 2484 0 Anticipated Thickness of Structural Fill, ft: 0 v � Moisture Counts: 695 Lance below Existing Ground and location of measurement, in: Municipality: Garfield Surveying and elevation validation are outside of the scope of w ork and w ere not performed by HBET. Lab #: 1/1/2375 Max. Dry Density, pcf: 108.0 Opt. Moisture, %: 15.5 Proctor Type: D698 A laterial Classification: Engineered fill Pass Not Applicable 2 Specification: 95 , -2 to +2 D698 N Location: d e v a o _ CL c w w m Remarks / F w 0- a 0 i v° w Rock Corrected Proctor Values: 17.0 6 95% Pass 108 pcf @ 15.5 % Moisture 4 East Section 1 Not Applicable Proof -roll Pass Not Applicable 2 North Section 0 0 106.2 17.0 6 98% Pass 108 pcf @ 15.5 % Moisture 3 South Section 0 0 102.5 17.0 6 95% Pass 108 pcf @ 15.5 % Moisture 4 East Section 0 0 106.2 15.4 98% Pass 108 pcf @ 15.5 % Moisture 5 Northw est Section 0 0 106.3 17.0 98% Pass 108 pcf @ 15.5 % Moisture Comments: South section retested from 6-12-23, north west section retested from 6-12-23 6-15 Comments - 6 -12 2789 Riverside Parkway Client: Kay Crook ' 1 Hud(fleston-Berry Grand hmlion, CO, 81501 PO Box 1174 Engineering Testing, LLC $ .% :f 970l 255-8005 Rifle iNo�lw�r&Sccslnn6r:rrerom CO 81650 SOIL OBSERVATION REPORT Project: Parcel 217902400549 Approval: Retesting is Required Project Number: 02375 - 0001 Technician: Miriam Sanchez teviewed by: Jesse Lueras Work Order No: )bservation Date: June 12, 2023 Review Date: June 26, 2023 Geotechnical Report Title: Geotechnical Investigation Sub-Contractor: Ow ner Geotechnical Report Author: HBET On Site Notification: Ben Crooks Geotechnical Report No & Date: 02375-0001 12/16/2021 Foundation Type: Footing / Stem Wall Geotechnical Report Bearing Capacity, psf: 2000PSF Proof-roll equipment: Development or Lot Specific Report: Lot Specific Excavation Limits, ft: by Soil Type Observed: Native 1a I X (Gauge & Date of Calibration: 80082 9/9/22 E l �^�J roposed Type of Structural Fill for Next Lift: NA °Density Counts: 2490 Anticipated Thickness of Structural Fill, ft: 0 c 0 v Moisture Counts: 690 tante below Existing Ground and location of measurement, in: Municipality: Garfield Surveying and elevation validation are outside of the scope of work and were not performed by HBEr. Lab #: 1/1/2375 Max. Dry Density, pcf: 108.0 Opt. Moisture, %: 15.5 Proctor Type: D698 A laterial Classification: Engineered fill Specification: 95 , -2 to +2 D698 ik IL Location: ) 7 o '' c 0 w e a r c« E w m Remarks / F o $, a 0 a` 0 ' rn Rock Corrected Proctor Values: 1 Not Applicable Proof-roll Pass Not Applicable 2 South Section 0 0 106.5 10.0 6 99% Fail 108 pcf @ 15.5 % Moisture 3 Northw est Section 0 0 113.2 10.5 .. 6 105% Fail 108 pcf @ 15.5 % Moisture .... ...................... . Comments - 6 -12 2789 Riwrside Parkway Client: Kay Crook Grand Junction, CO, 81501 PO Box 1174 Huddleston -Berry 970I 255 -8005 Rifle Engineering & Testing, LLC \ ` A �nlnfdivxl7estcv�0�:rrvtrxn CO 81650 SOIL OBSERVATION REPORT Project: Parcel 217902400549 Approval: On-going Testing is Required Project Number: 02375 - 0001 Technician: Miriam Sanchez teviewed by: Jesse Lueras Work Order No: 85669 )bservation Date: May 18, 2023 Review Date: June 26, 2023 Geotechnical Report Title: Geotechnical Investigation Sub -Contractor: Ow ner Geotechnical Report Author: HBIET On Site Notification: Ben Crookl Geotechnical Report No & Date: 02375-0001 12/16/2021 Foundation Type: Footing / Stem Wall Geotechnical Report Bearing Capacity, psf: 2000PSF Proof -roll equipment: Full capacity wheeled skid -steer Development or Lot Specific Report: Lot Specific Excavation Limits, ft: 76 by 30 Soil Type Observed: Native1 7C ;Gauge &Date of Calibration: E I�� roposed Type of Structural Fill for Next Lift: Native c 0 Fx� Density Counts: 0 Anticipated Thickness of Structural Fill, ft: 1 v F—xl Moisture Counts: Lance below Existing Ground and location of measurement, in: 14" South bank Municipality: Garfield Surveying and elevation validation are outside of the scope of work and were not performed by HBET. Lab #: Max. Dry Density, pcf: - Opt. Moisture, %: - Proctor Type: - laterial Classification: - Specification: Proof -Roll Location N w ` C Q E; yd = y $ 0 o 0d o_ v O> � 1 Bottom of foundation excavation -1 Proof -roll Comments: .y w � Remarks / rn Rock Corrected Proctor Values: Pass No Deflection Observed 5-18