HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLMF-O6-23-8163
Martin Ranch ll LLC
2,255 SO FT SECONDARY DWELLING UNIT ON CRAWL SPACE
3602 CR 1OB CARBONDALE
MARTIN EXEMPTION, LOT 2, 239536400152
MANUFACTURED HOUSES ARE REGULATED & INSPECTED BY COLORADO DEPT. OF HOUSING (C.D.O.H.)
AND Att FACTORY.BUILT RESIDENTIAL STRUCTURES INSTALLED IN GARFIELD COUNTY MUST MEET
C.D.O.H. GUIDELINES FOR MANUFACTURE AND INSTALLATION AT THE JOB SITE.
1 ) FOUNDATTON CRAWL SPACE & EXTERTOR DOOR LANDTNG / STATRS SHALL COMPLY WITH 201s l.R.c.,
2OO9 I.E.C.C. AND MANUFACTURER'S INSTALLATION REOUIREMENTS.
2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY'S BUILDING REOUIREMENTS AND
MANUFACTURER'S INSTALLATION REOUI REM ENTS.
3) WILDFIRE MITIGATION IS REAUIRED PURSUANT TO PLAT NOTE #ó (ATTACHED FOR REFERENCE):
COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS COLORADO
STATE FORËST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY
COM M UNITY DEVELOPM ENT WEBSITE FOR ADDITIONAL I NFORMATION.
4) ALL PLUMBING & GAS PIPING CONNECTIONS MUST BE PERFORMED BY A CO LICENSED PLUMBER &
ALL ELECTRICAL CONNECTIONS MUST BE PERFORMED BY A CO LICENSED ELECTRICIAN.
5) ELECTRTCAL PERMtTTtNG AND TNSPECT|ONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL, IF ANY, WORK PROPOSED IN ATTIC LOFT. ELECTRICAL FINAL APPROVAL
REOUIRED FOR FINAL INSPECTION & CERT. OF OCCUPANCY.
ó) pRtoR To FTNAL BUtLDtNG TNSPECTTON & CERTIFTCATE OF OCCUPANCY, PROVIDE BUILDING
INSPECTOR WITH FINAL APPROVAL / SIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH
DEPARTMENT FOR INSTALLATION OF THE ON-SITE WASTEWATER TREATMENT SYSTEM.
7) A LOT IMPROVEMENT CERTTFTCATE SEALED BYA COLORADO LTCENSED SURVEYOR lS REOUIRED
AT FOUNDATION INSPECTION TO VERIFY STRUCTURE - INCLUDING ROOF OVERHANGS, DECKS &
OTHER PROJECTIONS _ COMPLIES WITH MINIMUM SETBACK OR BUILDING ENVELOPE REOMTS.
8) BUtLDING PERMtTAPPLTCATTON HAS BEEN PROCESSED CONCURRENT WITH AN ADMINISTRATIVE
APPROVAL GAPA-05.23-89ó5 FOR CONSIDERATION OF A SECONDARY DWELLING UNIT. SEE
ATTACHED DIRECTOR DECISION LÊTTER. WATER PUMP AND OUALIry TEST RESULTS TO BE
COMPLETED AND REPORT PLACED IN COMMUNITY DEVELOPMENT FILE GAPA-05.23-89ó5 PRIOR TO
ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
9) cARFtELD COUNTy BUTLDTNG DEPT. TNSPECTIONS TO TNCLUDE THE FOLLOWING:
A. FOOTINGS DESIGNED AT 2,500 PSF, VERIFY 3ó INCH MINIMUM FROST DEPTH & UFERGROUND
INSTALLED, OPEN HOLE SOILS REPORT PREPARED BY THE GEOTECHNICAL ENGINEER IS
REQUIRED AT FIRST FOOTING INSPECTION. OWNER BUILDER IS RESPONSIBLE TO NOTIFY THEIR
PROFESSIONAL GEOTECHNICAL ENGINEER (KUMAR & ASSOCIATES)ONCE EXCAVATION OF THE
ACTUAL FOUNDATION AREA IS COMPLETED _ GEOTECH SHALL REVISITTHE JOB SITE TO
OBSERVE AND VERIFY ACTUAL SOIL CONDITIONS TO PREPARE THE "OPEN HOLE REPORT" FOR
THE OWNER - PROVIDE WRITTEN 'OPEN HOLE SOILS REPORT'TO THE GARFIELD COUNTY
BUILDING INSPECTOR AT FOOTING INSPECTION.
B. FOUNDATION WALL INSPECTION
C. SEPTIC SYSTEM CONNECTION
D. PLUMBING/GAS
E. IF ANY SITE FRAMING, STAIRS, GUARDS OR HANDRAILS.
F. FINAL INSPECTION & CERTIFICATE OF OCCUPANCY*
*NOTE: GARFIELD COUNTY REOUIRES C.D.O.H. INSTALLATION INSIGNIA TO BE AFFIXED PRIOR