HomeMy WebLinkAboutOWTS System DesignK-CRO¡\rI(P.A. Box 4o
Mack, CO
g7 o. 2to.ol7 2 f kat'hayla.n'onl¿@outloo/<.conr
Onsite W'astewater lreatment System Depign
July I0, ZO23
Ross Project
I84O -293- County Road
Rifle, CO 81620
Parcel N,o. 2I77-I0I -00-208
Prepared By:
K-Cronk Engineering, Inc.
P.O. Box I4O
Mach CO 81525
970¿50-4572
Site History
There is an existing four-bedroom residence on the site that is served by an existing onsite wastewater
treatment system (OWTS). The existing system has been slow draining and requires pumping three to four
times per year. The orüner of the property wishes install a new OWTS while also maintaining the existing
system as an alternative field.
The site consists of approximately 3.0 acres of uncultivated native soil. Drainage is approximately I % to
the east. A percolation (pn c\ test/soils evaluation and site study were conducted on the property of
reference on O612912023 by Kachayla R. Cronk, registered professional engineer (RP-E.). The perc
excavation trench was located approximately 65' north of the south property line and approximately 50'
west of the east property line.
This OWTS design has been prepared for theproject based on information disclosed during the site study
mentioned above. A discussion of the engineered OWTS design follows. The perc test/soils evaluation is
attached for reference as Appendix A. The location of theperc excavation trench is shown on the Plot Plan
included in this report.
Develooqent of Þesien Parameter.s
The perc excavation trench was extended to a depth of 100" below ground surface (BGS). There was no
evidence of ground water or high seasonal water table in the open excavation to a depth of I 00" BGS. The
soils evaluation indicates two distinct soil horizons underlie the site. A lithological description follows:
depth (in.) description
0" - 18',
l8'- 100"
sandy loam, brown
(Soil Type 2, USDA * sandy loam, granular, moderate structure)
loamy sand, light brown
(Soil Type t, USDA * loamy sand, single grained, structureless)
Based on the rcsults from the t6129123 perc testlsoils evaluation (Appendix A), an long terrn acceptance
rate (LTAR) of 0.60 has been chosen for overall system sizing for an infiltrator trench soil treatment a¡ea
designed to discharge to subsoils below the 48" depth.
-l-
System Design
An INFILTRA?OI? trench soil treatment system is proposed for discharge of septic effluent at the site.
Construction ofthe system will consist of excavating level trenches in the area comprising the soil treatment
¿16¿. Gradins durinq constructlon mav affect slpne^ therefore contractor sha4 verifv slone at time of
installntion. Soil treatment area orientåtion may be adiupted oer site variationq,tp facilitatp consistent
trench denth runnins oar¡llFl to final contoqrs. The initial excavation shall be continued to a level depth
of 48" BGS (see Soil Treatment Are¿ Cross Section). If consistçnt tren,ch deÞth çlmnot be maintain€d.
{NFILIÀ,4IOR chambe{s r,na}¡ be installed level at 24" miqimum and 48" mærimum BGS.
Following completion of the trench excavations, QUICK4 STANDARD INFILTRATORS (or equivalent)
will be used to construct a septic efiluent distribution system in the open exc¿vations. The INFILTRATOR
effluent distribution system wi[ be installed in accordance with the "Infiltrator Technical Manual",
available from Infiltrator Systems Inc., 123 Eûn Street, Suite 12, Old Saybrook, Connecticut 0ó475.
Adiacent 1¡I/F/¿ZA,,4ZOA,S shall be fasteged with a r,ninir,num of three 1.3) %" pelf-taop-ing screws to prevent
movgment and seoaration dgJins backfilling.
After the INFILTRATORS arc installed, synthetic filter fabric (140-200 mesh) will be placed over the
INFILTRATORS and the system will be covered with a soil cap. The soil cap will consist of approximately
36" of nativc soil backflrll. The soil cap will be mounded 5% above the existing ground surface to promote
surface run offaway from the soil treatment rirea'
The installershould confirm the feasibility of gravity discharge of sewage effluent from the foundationline
to the soil treatment aretby field verification of assumed desþ parameters. Assumed design parameters
with respect to gravity discharge include:
If the distance from the sewage pipe at exit from the foundation line to the soil treatment area
is 150'or less,
The elevation of the ground surface at entry to the soil treatment area shall be no more th,an 17'
above the invert elwation of the sewage pipe at exit from the foundation line.
If field measurements do not confirm these design assumptions, gravity discharge of septic effluent from
the proposed structure cannot be assured and a lift station may be required. Please contact the design
engineer and Garfield County to address any design modifications necessary if these desþ assumptions
are not upheld.
There is an existing 1,250 gallon, two compartmentseptic tankthat is in good working order and will
remain in use to provide a minimum of 48 hours retention time for sewage generated from the proposed
project. A non-corrodible Orenco filter (model # FTW0436-28) shall be installed at the final outlet tee of
the septic tank to limit the size of solids and sludge passing into the soil treatment area. The filter must be
accessible for cleaning and replacemçnt from the ground surface. A distribution box is required to provide
equal disribution of septic effluent from the septic tank to the soil treatment area laterals. The installer shall
replace the existing distribution box with a new one. The distribution box must be placed on stable native
soil or compacted structural fill to prevent settling and assure equal distribution of septic effluent. The
distribution box must be accessible for cleaning and replacement from the ground snrface.
The existing STA \Ã/iU remain in use as an alternative system should it ever be needed. IN ORDER TO
a
ra
_1
ALLO\il THE EXISTING STA TO BE USED AS AN ALTERNATIVE SYSTEM, THE INSTALLER
SHALL PROVTDE AN OUTLET FROM THE DISTRIBUTION BOX TO THE EXISTING STA. SPEED
LEVELERS WILL BE PROVTDED SO THE OUTLET TO THE EXISTING STA IS HIGHER THAN
THE OUTLETS TO TTIE NEW STA, ENSURING TTIAT THE EXSTING STA WILL ONLY BE USED
IN AN OVERFLOW CONDITION.
As shown in the included graphics, the trench soil treatment system will consist of four (4) trenches 3' wide
x 48" deep x 52' long with thirteen (13) INFLLTRATOR (or equivalent) units each for a total of fifty+wo
(52) units. The soil treatment area will encompass a¡r effective area of 891.43 sq. ft.
DESIGN CALCULATIONS
DESIGN LOADING RATE OF 3 BEDROOMS @ 150 GAL./BEDROOM-DAY :450 gal./day
PLUS 4th BEDROOM @75 G1"J,.IBEDRCIOM-DAY = 525 Bal.lday
DESIGN LONG TERM ACCEPTANCE RATE (LTAR) = 0.60 GAL./SQ-FT./DAY
a
LTAR,A_WHEBË,
A = SOIL TREATMENT AREA (SQ. FT.)
Q- DESIGN FLO\M (GAL./DAY)
LTAR = LONG TERM ACCEPTANCE RATE (GAL./SQ.FT./DAÐ
A:#= 875s0'Fr'
SOIL TREATMENT AREA ADruSTMENT FACTOR FOR GRAVITY TRENCH DESIGN = I.O
SOIL TREATMENT AREA ADruSTMENT FACTOR FOR USE OF CHAMBERS = 0.7
ADruSTED SOIL TREATMENT AREA:875 SQ.FT. X 1.0 X 0.7:612.5 SQ. FT.
LENGTH OF 3' WIDE TRENCH REQ'D : 612.5 SQ.FT. I 3 FT. = 204.17 FT.
USE 4 TRENCHES WTïH 13 QUICK4 STANDARD INFILTRATORS (or equivalent) EACH FOR A
TOTAL OF 52 UNITS
SOIL TREATMENT AREA SIZED AT 4 TRENCHES 3 FT. \MDE X 52 FT LONG:624 SQ. FT.
lnstallation - Setbacks. N gtifiçatigns. afrd In speqtion s
The owner and installer shall be aware of and comply with the following installation and system operation
requirements.
a
a
The installer must be approved and licensed by Garfield County for installation of onsite
wastewater treatment systems.
All þstallation activitiesshallbe coqductedin accordance with cune+t GarfieldCounty0ør/^S
A¿E¿lqû'pr¡s. lf at 4ny time durine construction. suþsurface qite conditions are encounter€d
which differ from lhE desim parameters previouslv described. construction activities will stop.
and thedesisn engiqegr and Garfield,Countl' )a4Í be contactedto 4ddress a¡y neçessarv design
modiûcations.
The final cover shall not be placed on sewer lines, septic tank, or the soil treatment areauntil
thesystemhasbeen inspectedandapproved bythedesign engineerand Garfield County. The
installer shall provide 48-hour notice for all required inspections.
Installation procedures includinggrade, location, setbacks, septic tanksize, and soil treatmsrt
size shall conform with the attached graphic details. Construction activities and systern
components will not encroach upon existing easements or utility corridors. A minimum of 5
ft of undisturbcd soil shall be mairttained between individual absorption elements and the sepfic
tank. A minimum of 4' of undisturbed soil shall be maintained between adjacent absorption
elements.
The installer must maintain all setbacks to utility linesn easements, property lines, or other
adverse conditions, whethertheyare known and shown on the attachedgraphics or have been
disclosed during construction. Vehicle traffic and parking is to be prevented over the soil
trcatment and repair area. Minimum setbacks for system components are:
a
a
a
a
Source Septic Tank
domestic water line l0'
domestic well 50'
domestic watcr cistern 50'
property lines 10'
structure dcrawl space 5'
structure w/o crawl spaceS'
irrigation ditchopen 50'
intermittentiniption 10'gated l0'
solid pipeilined 10'
Soil Treatment Arep
25'
100'
100'
l0'
20'
10'
50'
25'
2s',
l0'
All gravity flow sewer lines and effluent distribution piping shall be 4 inches in diameter and
have glued joints. All lines discharging sewage from the residence to the septic tank shall
maintain a minimumfall of 1/8 in. per foot and shall employ sweep 90's or 2-45's at all turns.
Sewer lines from the dwelling to the septic tank and at least 6 ft from the septic tank outlet
must meet minimum standardASTM-3034. Lines discharging from the septic tank to the soil
trçatmentarea shall maintain a minirnumfall of 1/8 in. per foot. Sewer lines under driveways
shall meet the minimum Schedule 40 PVC standards. Additionally, efïluent piping in traflic
areas with less than 24" of cover shall be encased in 6" CMP or flow fill and covered with
minimum 2" high density blue board insulation.
=4-
Sewer lines or domestic water lines shall be encased in minimum SCHD 40 with water-tight
end caps or a minimum of 6" offlow fill at all points with less than 5' separation between sewer
and domestic water lines.
Four-inch clean outs shall be installed at maximum 100' intervals in all gravity flow efflue,nt
lines çxceeding 100'in length.
A minimum of 12" of soil cover (18" recommended) shall be maintained over all gravity
draining OWTS components to prevent freezing ofseptic eflluent (excepting septic tank access
ports which must be extended to the ground surface).
The system contractor shall be aware of the potential for construction activities to reduce soil
permeabilities al the site through compaction, smearing, and shearing. The following
precautions and construçtion procedures should be employed during installation to minimize
disturbance to native soils:
i. Excavation should proceed only when the moisture content ofthe soil is below the
plastic limit. If a sample of soil forms a rope instead of crumbling when rolled
between the hands it is too wet and should be allowed to dry before excavation
continues.
ii. Excavation and backfill equipment should work from the surface where at all
practical to avoid compaction of the soils at depth.
iii. The bottom and sidewalls of the excavation should be left with a rough, open
surface. The appearance should be that ofbroken or tipped soil as opposed to a
sheared, smeared or troweledsurface. Any smoothedor smeared surfaces should
be removed with a toothedrake or shallow ripper, taking care to remove loose
residues from the bottom of the excavation by hand if necessary.
iv. Care should be taken in placing fill materials in the excavation to avoid damaging
the exposed soil surfaces.
Operation - Maintenanc.e pnd Inspectionq
o The owner shall install a structural barrier ifnecessary andtake precautions to prevent vehicular
traffïc, excessive surface watering, accidental flooding, or other activities in the vicinity of the
soil treatment area which may compact, saturatg or otherwise alter the subsurface soil
parameters used in designing the septic system.
o The ownerwill plant and maintain grass or othershallow rooted cover crûp to prevent erosion
and promote evapotranspiration over the soil treatment area.
e The owner will inspect and maintain the required mounding and drainage away from the soil
treatment area to prevent saturation from precipitation and surface flows-
r To mitigate the generation of preferential flow channels which may compromise the operation
of the system, the owner will inspect and prevent intrusion of bunowing animals and deep-
rooted plants into the soil treatment area.
o The septic effluent filter shall be inspected and cleaned as necessary every six (6) months.
o The owner will conduct periodic maintenance ofthe septic system by removing accumulated
sludge ftom the septic tank every 3.4 years to prevent clogging of the soil treatment area.
o
a
a
a
5
Limitations
This report is a site-specific design for installation of an onsite wastewater treatment system and is
applicable only for the client for whom our work was performed. Use of this report under other
circumstancesis not an appropriate application of this document. This report is a product of K-Cronk
Engineering, lnc. andis to be taken in its entirety. Excerpts f¡om this report may be taken out of context
andmaynotconveythetrueint€ntofthereport. [tistheowner'sandownedsagent'sresponsibilitytoread
this report and become familiar with the recommendations and design guidelines contained herein.
The recommendations and design guidelines outlined in this report are based on: 1) the proposed site
development and plot plan ¿s fumished to K-Cronk Engineering, Inc. by the client and 2) the site conditions
disclosed at the specific time of the site investigation of reference. K-Cronk Engineering, Inc. assumes no
liability for the accuracy or completeness of information firrnished by the client. Site conditions are subject
to external environmental effects and may change over time. Use of this plan under different site conditions
is inappropriate. lf it becomes apparent that current siteconditionsvary from thoseanticipated, thedesign
engineerand Garfield County shouldbe contactedto develop any required design modific¿tions. K-Cronk
Engineering, Inc. is not responsible and accepts no liability fot any variation in assumed design parameters.
K-Cronk Engineering, Inc. represents this report has been prepared within the limits prescribed by the
owner and in accordance with the current accepted practice of professional engineering in the area. No
Ìvârrânty or representâtion, either expressed or implied is included or intended in this report or in any of
our contracts.
SEAL
o
Date
NOTE: This OWTS design is meant to include the following fÏve pages:
1) plot plan
2) septic layout plan
3) notes for your installer
4) soil treatment area plan vlew
5) soil treatment ¡rea crois section.
The ptan is not to be implemented in the absence of these sheets. ln addition, results from the
percolation test and soils evaluation are included for reference as Appendix A.
6
eJ or¡ao Í
Iocqtlonof neu
ex¡stlng
resldence
Ê
gu
Fzlcf(J
Icî
c
ru
I
T-t
--J
perc
excovotlon
trench
I
I
I
þ_
RT]SS PRNJECT
tg40 -¿93- ttlUNTY RgA!
a711-101-00-e08
PLET PLAN
JULY 10, EOA3
SCALET 1'=50'NORTH
NI]TE
INSÏALLER TI] ENSURE EXIST]NG
SEPTIC TANK HAS AN EFFLUENT
FILTER (I]ST MODEL FTVO436-28)
NOTE
CALL 8It FfR UT¡L¡TY LOCATES
PROJECT
-?93- CI]UNTY ROA!
+
û
NORTH
77-101-û0-208
LAYOUT PLAN
Y 10, ?0?3
1'=30'
NBTE
JNSTALLER SHALL USE SPEED
LEVELERS IN ÏHE D-BtrX TN
ISOLATE EXISTING STA FREM NEV
STA. THE ELEVATItrN OF THE
IUTLET PiPE TD THE EXIS'|ING STA
MUST BE HIGHER THAN THE OUTLET
P]PES TO THE REPLACEMENT FIELI)
Ttr ENSURE IÏ IS T]NLY USEII IN AN
BVERFLOV CONDITION
exlstlng
nesldence
GRAVITY BISCHARGE OF SEVAGE
EFFLUENT FRBM THE RESIIENCE
Tg THE I}ISPI]SAL SYSTEM iS
BASED BN THE FOLLOVING DESIGN
ASSUMPTiBNST
LENGTH OF SEVAGE PIPING
FRI]M EXTT AT FT]TJNDATIEN
L]NE Tg ENTRY TO St]IL TREATMENT
AREA = 150' 0R L€SS
ELEVATII]N OF GRI]UNÐ SURFACE
AT ENTRY TI] S[]IL TREATMENT AREA
= NB MBRE THAN 18, ABI]VE THE
INVERT ELEV, DF SEVAGE PIPE
AT EXIT FROM FT¡UNNATIITN LINE
ÐISCLAIMER
TF THESE DESTGN ASSUMPTIBNS ARE
NOT UPHELD DUR¡NG CTNSIRUCTION,
GRAVTTY DISCHARGE CAN NNT BE
ASSURED AND A LIFT STAÏ]ON MAY
BE REOUIRED
Nt]ÏE
NI]TE
FBLLCIVING SETBACKS MUST BE MAINTAINEС
SEPTICÏANK STA
100'
50,
e5'
?s',
10,
100'
e5'
?o'
10'
10'
SELID PIPE/LINED DITCH
DEMESTIC \^/ATER CISTERN
-5û/DTMESTIC WATER LINE
STRUCTURE
STRUCTURE V,/üCRAVLSPACE- 5'
PRoPERTY LINE
-10,
THE
50'
50'
10'
10'
DITCH_
NETE
CÍü.¡TRACIOR Tt] VERIFY
SLBPET SOIL TREATT{ENÏ
AREA ORIENIAÍIIIN 10 3E
AT'JUSTED PER S¡TE
VAR¡ATTONS TO FACILITAÎE
CI]NSISTENT TRENCH IEPTH,
RI.T.¡NING PARALLEL TO
ctrTouRs.
r I
r;il-]
nln, ofÊset to wel
Ê{t3u
t--zf,E(J
I
cr)
Or
CU
I
r-)
_-r-1ål>
Lijd.
à8_é
uì' u
i?€ı9:,ù'
uÈ-ô l.r)
üëlo.lo,lr
-t
_-rtåt>l_Po..>r¡+o.ó
uì' u
ù:ÊıÉ:,È'
qÈ'otñ
fiðlltolo.lç
-t
exlstlng STA to
refrrln ln p(oce os
:t:-
otternotlve syste¡'r
perc
excôvotlon
trench
soll tneotncnt tneo (STA)
conslstlng of 4 rows of 13
Ouick4 Stqndord Infittrotons(on equlvotent) for o totql, offlfty-two units
drlve
use (see note)
no.into,in
llne fro¡ì tonk
d-þox if grode
ol(orrs
I
¡- 10' - r
I hln. i
16' Feconnended
locqtlon
of we[[
ì
K-CRO¡\r/(P,O. Box 4o
Madl CO
g7o. 2ro.ot7 2 f karhayl a.u onÊqaourlooÈ.cortt
NOTES FOR YOUR INSTALLER
. Please veriff slope at the time of system installation - the orientation of the
STA shown in this design has been determined based on existing site
conditions at the time of the original site investigation, but that may have
changed during construction and pre-construction grading of the site.
. The depth of the trenches is determined by percolation rates and soil
conditions relative to the existing ground surface at the time of the soils
investigation. If the site sþe or grading of the ground surface at the time of
installation differs sþificantly from what was initially observed, the trench
depths may have to be adjusted to make sure the infilhative surface remains
in the desired soil layer, and portions of the trenches don't end up too deep or
too shallow. The dep-th of the soil qap relative, to finished erading ls not part
of thq OWTS desien criteria.
o Please provide K-Cronk Engineering with a copy of the septic tank
manufacturer's specification sheet veriffing maximum backfill depth. Tanks
must be backfilled according to manufacturer's specification,
Pressurized System Notes
r Please provide K-Cronk Engineering a copy of the sand sieve analysis, if
relevant, dated within 30 DAJS of installation before purchasing/installing
the sand so we can checkthat it meets Mesa County OWTS standards.
. Pump floats do not come pre-set from the factory. Please refer to the Pump
Vault Detail for the distance needed between the on/offfloats.
Please reach out at any time during the installation process ifyou have any questions!
Kachayla Cronk - (970) 250-0572
outtet to ex. STA(to þe qt hlghen
etevû.t¡on thûn
othen outtets)
tlc
distribution
loox
îostenw/ (3)odJocent Inflltnotors3/4' screws at
outlets to new
STA, typ. 4 o, 4
57' w/ endcops,
of çhrnbers,
solt treotnent areq (SlA)
conslstlng of 4 rows oÊ 13
0ulck4 Stondqrd Inflttrqtons(or €qulvotent) for r totûtof 52 unlts
to dlstrlbutlon
box, typ.
ì5ùILùç
o,(
Ô-
ù
ûr I
f F--+l
g a8', +yp.
prov¡de lnspe c+lan / v entlng ponts
ot eqch Pnd of lnflttrqtÖr
trenches os shown
StrIL TREATMENT AREA - PLAN VIEV
STALE¡ l'=10'
(TYPICAL A fTF 4)
RNSS PRNJECT
1840 -293- CEUNTY RUAI)
a177-101-00-e08
St]tL TREATI1ENT AREA.PLAN VIEV
JULY 10, EOE3
SCALE' l'=10'
SCREV IIETAIL
NTS
opproxlnotety 10 o'ctock, le
o'ctock, ôñd e o'clock posltlon,
tvp'
(10' reco¡lnended)
screws, typ.(see detolt)
4' nln.
o
I
a
?Y3t o
I16
SI]IL CAP (MOUN! 5Z)
PRNVIDE VENTING/INSPECTITN
PI]RTS AS REOUIRED BY
INFILTRATSR INSTALLATlNN
CUIDEL]NES, TYP. AI ENTS I]F
EACH RtrV (ONE EF TVB)
EXISTING GROUND SURF
{)(''oç
36',-.
SYNTHETIC FILTER
TABRIC I]VER
INFILTRATDR, TYP.SEE NOTE
D]SK ER SCARIFY, TYP.
EUICK 4 SÏANDARD INFILTRATT]R, INSTALL IN
ACC0RDANCE V¡IH'INFILTRTqT0R TÉCHNICAL MANUAL,
INFILTRATTR SYSTETIS INC., IA3 ELI"I
STREET, SUTTE le, t]LD SAYBRNOK,
CNNNECTICUT 06475
NETE'
IF CBNSTSTENT TRENCH DEPTH
CANNI]Ï BE MAINÏAINED,
INFILTRATTR CHAMBERS MAY BE
INSTALLED LEVEL AT E4' MIN,
AND 48' MAX BGS
SI]IL TREATMENT AREA - CRI]SS SECTION
(ÏYPTCAL 3 EF 4)
SCALET l'=5'
ELEVATIEN ÐESIGN SPECIFICATIBNS
DESIGN DISTANCE FROM FUUNDATIIIN LINE Tfl SEPTIC TANK = 30'
DESIGN DISTANCE FRUM SEPTIC TANK T0 DISIRIEUTIoN BOX = 85'
ASSUMED ELEVATIBN EF 6R0UND SURFACE AT ENTRY Tt SDIL TREATMENT AREA - 100.00'
ELEVATION T]F INFILTRATIVE SURFACE NF SOIL TREATMENT AREA = 96,00,
INVERT ELEVATI0N OF SEIIAGE LINE AT EXIT FRÛM DISTRIBUTITIN 30X = 96.58'
INVERT ELEVATION t¡F SEVAGE LINE AT EXII FRUM SEPTIC TANK = 97.43'
INVERT ELEVATI0N 0F SE\IAGE LINE AT EXIT FR[]M F0UNIIATIUN LINE = 98,28'
BUTLETS AS RESU]RED
-14',
-100'
STILS LTTG
(SEE NOTES)
ROSS PRIIJEC''
1840 -?93- CUUNIY RnA¡
2177-a01-00-a08
SI]IL TREATMENT AREA - CROSS SECTII]N
JULY 10, ¿OE3
SCALË¡ AS SHOVN
DTSTRIIUTION DgX DETA¡L
scALE',r'=r'
st
s¿
¡ INt-Er
ÏED NATIVE SOIL OR STRUCTURAL
TT PREVENT SETTL1NG
SI]ILS LOG NI]TES
*1 - SANIY LOAM, BREVN
(USDA-SANDY LOAM, GRANULAR, PITDERATE STRUCTURE)
#2 - LBAMY SAND, LIGHT BROU/N
(USDA-LBAMY SAND, SINGLE 6RAINED, STRUCTURELESS)
NB GROUNOVATER DR HIGH SEASI]N¡AL Vê'TER TABLE OBSERVEN TO A
DEPTH T]F 1OO' BELI]V GRBUND SURFACE (BGS)
Appendix A
Soils and Percolation Report
K-CRO¡\rI(P.O. Box 4o
Mack, C()
g7o.zro.o57 2 f kachayla.cr o¡rl<@ourloo/<.rcnt
Soils end Percol¿tion
lune 29,2023
Rçort
Ross Proiect
I84O -293- County Road
Rifle, CO 81650
Parcel No. 2T77-I0I -00-208
Prepared By:
K-Cronk Engineering, fnc.
P.O. Box I40
Mack, CO 81525
970-250-0572
Soils Evaluation
The site consists of approximately 3.0 acres of uncultivated native soil. Drainage is approximately
Ío/o to the east. A percolation Qterc) test/soils evaluation and site study were conducted on the
property of reference on 06129/2023 by Kachayla R. Cronk, registered professional engineer
(R.P.E.). T\e perc excavation trench was located approximately 65' north of the south property
line and approximately 50' vrest of the east property line.
The perc excavation trench was extended to a depth of 100" below ground surface (BGS). There
was no evidence of ground water or high seasonal water tabte in the open excavation to a depth of
100' BGS. The soils evaluation indicates ¡wo distinct soil horizons underlie the site. A lithological
description follows:
depth-(jn.) desc{iption
0" - 18"sandy loam, brown
(Soil Type 2, USDA - sandy loam, granular, moderate structure)
loamy sand light brown
(Soil Type 1, USDA - loamy sand, single grained, structureless)
18" - 100"
Perc holes were constructed at the surface and at depths of approximately 40 in. and 72 n. The
holes appeared to be well saturated at the time of the test. Results of the percolation test are shown
in Table l.
TABLE 1
Percolation Test Results
1840 -239- CountyRoad
Depth Time on 06/29/2023 Time
Drop
Perc
Rate
min/in10:08 l0:24 10:38
0" - 12"5.5 11 .5 14.25 30/9 âJ
40" - 52"8.25 12.5 t4.5 3016.2s 5
72" -84"5.875 9.7s 13 30/7 4
1
Limitaüons
This document is representative of the site conditions disclosed at the specific time of the site
investigation. Site conditions are subject to change from external events both manmade (irrigation
or water feature conshuction) and naturally occurring (flooding or excessive precipitation).
K-Cronk Engineering, [nc. is not responsible and accepts no liability for any future variation in
site conditions.
K-Cronk Engineering, lnc. represents this report has been prepared within the limits prescribed by
the owner and in accordance with ttre current accepted practice of professional engineering in the
area. No warranty or representation, either expressed or implied, is included or intended in this
report or in any ofour contracts.
SEAL ,e 0t"¿
Kachaylffi.. Cronk, P.E.
o6/2-?/z-a
Date