Loading...
HomeMy WebLinkAboutRescheck Report 08.17.2023REScheck Software Version 4.7.2 Compliance Certificate Project 46 High Point Dr Energy Code:2009 IECC Location:Glenwood Springs, Colorado Construction Type:Single-family Project Type:New Construction Orientation:Bldg. faces 270 deg. from North Conditioned Floor Area:2,443 ft2 Glazing Area 17% Climate Zone:5 (7313 HDD) Permit Date:6/1/22 Construction Site: 46 High Point Dr Glenwood Springs, CO 81601 Owner/Agent: John Wheeler 46 High Point Dr Glenwood Springs, CO 81601 Designer/Contractor: BLRE-05-22-7498Permit Number: Compliance: Passes using UA trade-off 19.4% Better Than Code Maximum UA:453 Your UA:365 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: NOTE: Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on- grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA West Wall Living: Wood Frame, 16" o.c. Orientation: Front 400 25.0 6.0 0.038 0.057 11 16 direct set glass: Wood Frame:Double Pane with Low- E Orientation: Front 20 0.320 0.350 6 7 150 Living room: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Front 42 0.320 0.350 13 15 168 Living Room: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Front 30 0.320 0.350 10 11 145 Living Room: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Left side 30 0.320 0.350 10 11 West Wall Bed/entry: Wood Frame, 16" o.c. Orientation: Front 300 25.0 6.0 0.038 0.057 9 14 165 Bed 1: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 20 0.320 0.350 6 7 Side Lite: Wood Frame:Double Pane with Low-E Orientation: Unspecified 8 0.320 0.350 3 3 Project Title: 46 High Point Dr Data filename: C:\Users\Jack Wheeler\Documents\46 High Point Dr\MEP Design\46 High Point Dr ResCheck.rck Page 1 of 3 08/17/23Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Side Lite: Wood Frame:Double Pane with Low-E Orientation: Unspecified 8 0.320 0.350 3 3 Front Door: Solid Orientation: Unspecified 21 0.170 0.350 4 7 South Wall Living: Wood Frame, 16" o.c. Orientation: Left side 375 25.0 6.0 0.038 0.057 12 18 165 Kitchen: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 20 0.320 0.350 6 7 150 Living room: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Front 42 0.320 0.350 13 15 East Wall Kitchen: Wood Frame, 16" o.c. Orientation: Back 225 25.0 6.0 0.038 0.057 7 10 Dining Slider: Glass Orientation: Unspecified 41 0.330 0.350 14 14 South Laundry/master: Wood Frame, 16" o.c. Orientation: Left side 585 25.0 6.0 0.038 0.057 16 24 183 Mud Laundry: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 12 0.340 0.350 4 4 149 Master Bedroom: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 42 0.320 0.350 13 15 172 Stairs: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 30 0.320 0.350 10 11 172 Stairs: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 30 0.320 0.350 10 11 Direct Set Glass: Wood Frame:Double Pane with Low- E Orientation: Unspecified 30 0.320 0.350 10 11 Mud Door: Solid Orientation: Unspecified 21 0.170 0.350 4 7 East Wall Masters: Wood Frame, 16" o.c. Orientation: Back 550 25.0 6.0 0.038 0.057 19 29 165 Master Bath: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 20 0.320 0.350 6 7 145 Master Bed: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 30 0.320 0.350 10 11 North Wall: Wood Frame, 16" o.c. Orientation: Right side 698 25.0 6.0 0.038 0.057 23 35 168 Lower Master: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Front 30 0.320 0.350 10 11 163 Master Bath: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 9 0.320 0.350 3 3 183 Lower Master Bath: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 12 0.340 0.350 4 4 183 Bath 1: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 12 0.340 0.350 4 4 165 Office Nursery: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 20 0.320 0.350 6 7 Project Title: 46 High Point Dr Data filename: C:\Users\Jack Wheeler\Documents\46 High Point Dr\MEP Design\46 High Point Dr ResCheck.rck Page 2 of 3 08/17/23Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA West Wall 2nd Floor: Wood Frame, 16" o.c. Orientation: Front 313 25.0 6.0 0.038 0.057 10 14 172 Stairs copy 2: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Unspecified 30 0.320 0.350 10 11 168 Office Nursery: Vinyl/Fiberglass Frame:Double Pane with Low-E Orientation: Front 30 0.320 0.350 10 11 Lowest Roof: Flat Ceiling or Scissor Truss 450 49.0 0.0 0.026 0.030 12 14 Mid Roof: Flat Ceiling or Scissor Truss 900 49.0 0.0 0.026 0.030 23 27 Upper Roof: Flat Ceiling or Scissor Truss 810 49.0 0.0 0.026 0.030 21 24 Floor 1: Slab-On-Grade:Heated Insulation depth: 2.5'190 15.0 0.724 0.033 0 0 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.7.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: 46 High Point Dr Data filename: C:\Users\Jack Wheeler\Documents\46 High Point Dr\MEP Design\46 High Point Dr ResCheck.rck Page 3 of 3 08/17/23Report date: