HomeMy WebLinkAbout Insulation CertificateÈ.'
EnergyPri¡ Insulatiotl, I¡rc.
l'O llox ?flùó, dnur,l Jrr¡*tt¡o, {.1Û 8150? Ollifc 97t1"6:!}"7122
Centilic*fe of I nsulation
The undersigned certifies that the listed insulation products have been installed in
accordance with the manufacturer's rerommended applicafions for these Products
Job Address:327 Blue Heron Vists
Glen
Trent McComb
Presi<Jent
EnergyPro Insulation, I¡rc.
NotcsR-V¿rlue Mntcrinl \{ork Âres
Cardhoard tra{Ilel into every other truss baY
for attie
R-38 Loose-fìll Fiberglass Ccilitg Area
R-38 Inst¿lled to non-blsivâble ceiling areas'Unfaced Fiberglass
Batts
Ceiling Area
R,2l Unfaced [riberglass
Batt
Exterior Tt'atls Installed to exferior rvalls of house.
R-23 'Installed to designated walls:Mineral Wool Ëxtcrior Walls
R-?r Krntl Faced Fiberglass
Batt
Extcrio¡ Walls lnstalled to Garagc / House Common Wall
R-r9 Unfuced þ'iberglass 'Bâtt :
ûarage Ext. Walls
Cardboa¡d baffles installed into every other tntss bay
at eaves for attic ventilati¡rn. Unfaced batt installe<J ar
-^-,t"t^--4t t ^-;ti--.
Loose-fìlI Fiberglass Carage Ceiling
Area
R-38
R-21 Unfaced Fiberglass
Bû17
Kneewalls Installcd to the open Kneervalls rvith FSK paper
installed to the b¿ck side as an air b¿nier s; needcd
Cun Foanl & Caulk Gaps aud Cracks Foarn all horizontal and veriicai penetrati,cns" CauiL
boltom plate, top plate nailers, stud packs, headex and
misc. eaos.
Air Intìltration
Air Infiltration 4 milPoly Ë,xtsrior Tfalls &
Ceilines
rrÊ loåm '?ênêiraliðhs'Per
Csde
Air lnfiläatioä''Fiferrätëd ñarir installıd i¡ito eleèirical & plurn birr g
penetrations per code. lnclueles lcrv expanding foanr
to all rvirxlorvs & doors.
Springs, CO 81601
¡a-3