Loading...
HomeMy WebLinkAboutRadon Inspection Report Radon Engineering Consultants 1338 Grand Ave Glenwoo d Springs, CO 81601 970-925-8802 Radon Inspection Report Test Location: Dave Cardiff Saddle Circle 133 Carbondale, CO 81623 Test For: Dave Cardiff Saddle Circle 133 Carbondale, CO 81623 I nspected By: Radon Engineering Co nsultants 1338 Grand Ave Glenwo od Springs, CO 81601 970-925-8802 Test Result: Pass Overall Average: 0.4 pCi/l EPA Av erage: 0.4 pCi/l Test Device Details: Serial Number: Model Number: Last Calibration: Next Calibration: Cal-Factors: Motion Error: values 300002436 1028XP 05/11/2023 05/11/2024 2.81 No Test Site Condi tion: val ues Test Summary: CRM Location: Start: Start: 08/15/2023 10:44 AM Stop: Stop: 08/17/2023 10:44 AM I nterval : Interval: 1 hr Duration: Duration: 48 hr *First 4 hrs of data excluded Radon Concentration: Min: 0.0 Max: 1.1 Average: 0.4 M easurement Units: pCi/l Comments: Lic/Cert Signature Inspection Report Date: 08/18/2023 Test device manufactured by SunRADON, LLC OneRADON™ Version 2.3.12 Page 1 of 6 Radon Engineering Consultants 1338 Grand Ave Glenwoo d Springs, CO 81601 970-925-8802 Radon Inspection Chart Test Result: Pass Test Location: Saddle Circle 133 Carbondale, CO 81623 Inspection Report Date: 08/18/2023 Test device manufactured by SunRADON, LLC Page 2 of 6 Radon Engineering Consultants 1338 Grand Ave Glenwoo d Springs, CO 81601 970-925-8802 Test Checklist ☑☑The location of the detector was selected so the detector was no t to be disturbed during testing. ☑☑The monitor was not placed in an area of high humidity such as: Kitchen, laundry roo m, cellar, spa ro om, garage, crawl space o r sump area. ☑☑The detector was not located near drafts caused by HVAC vents, windo ws and do ors. ☑☑The detector was not placed near areas of excessive heat, such as a fireplace or in direct sunlight. ☑☑The detector was placed within the breathing zone of at least 20 inches to 6 f eet above the f loo r and at least 1 f oo t below the ceiling if suspended. ☑☑The detector was not placed within 1 foot of outside walls of the ho me or within 3 f eet of any windo ws or doo rs to the exterior of the home. ☑☑Ceiling fans, portable dehumidifiers, portable humidifiers, portable air filters, and all window air co nditio ners are no t operated within 20 feet of the detector. Test Result: Pass Test Location: Saddle Circle 133 Carbondale, CO 81623 Inspection Report Date: 08/18/2023 Test device manufactured by SunRADON, LLC Page 3 of 6 Radon Engineering Consultants 1338 Grand Ave Glenwoo d Springs, CO 81601 970-925-8802 Test Table * Data from f irst 4 hours excluded from EPA calculations Date/Time Radon(pCi/l)Flags 08/15/23 11:44 AM 0.0 - 08/15/23 12:44 PM 0.4 - 08/15/23 01:44 PM 0.0 - 08/15/23 02:44 PM 0.0 - 08/15/23 03:44 PM 0.7 - 08/15/23 04:44 PM 0.7 - 08/15/23 05:44 PM 0.7 - 08/15/23 06:44 PM 0.4 - 08/15/23 07:44 PM 0.4 - 08/15/23 08:44 PM 0.0 - 08/15/23 09:44 PM 0.0 - 08/15/23 10:44 PM 0.7 - 08/15/23 11:44 PM 0.4 - 08/16/23 12:44 AM 0.7 - 08/16/23 01:44 AM 0.0 - 08/16/23 02:44 AM 0.0 - 08/16/23 03:44 AM 0.0 - 08/16/23 04:44 AM 0.4 - 08/16/23 05:44 AM 0.7 - 08/16/23 06:44 AM 1.1 - 08/16/23 07:44 AM 0.4 - 08/16/23 08:44 AM 0.7 - 08/16/23 09:44 AM 0.7 - 08/16/23 10:44 AM 0.7 - 08/16/23 11:44 AM 0.7 - 08/16/23 12:44 PM 0.0 - 08/16/23 01:44 PM 0.0 - 08/16/23 02:44 PM 0.4 - 08/16/23 03:44 PM 0.0 - 08/16/23 04:44 PM 0.4 - 08/16/23 05:44 PM 0.4 - 08/16/23 06:44 PM 1.1 - 08/16/23 07:44 PM 0.0 - 08/16/23 08:44 PM 0.4 - 08/16/23 09:44 PM 0.0 - 08/16/23 10:44 PM 1.1 - 08/16/23 11:44 PM 0.0 - 08/17/23 12:44 AM 0.4 - 08/17/23 01:44 AM 0.4 - 08/17/23 02:44 AM 0.7 - 08/17/23 03:44 AM 0.4 - 08/17/23 04:44 AM 0.4 - 08/17/23 05:44 AM 0.0 - 08/17/23 06:44 AM 0.0 - Test Result: Pass Test Location: Saddle Circle 133 Carbondale, CO 81623 Inspection Report Date: 08/18/2023 Test device manufactured by SunRADON, LLC Page 4 of 6 Radon Engineering Consultants 1338 Grand Ave Glenwoo d Springs, CO 81601 970-925-8802 Test Table * Data from f irst 4 hours excluded from EPA calculations Date/Time Radon(pCi/l)Flags 08/17/23 07:44 AM 0.4 - 08/17/23 08:44 AM 0.0 - 08/17/23 09:44 AM 0.7 - 08/17/23 10:44 AM 0.0 - Test Result: Pass Test Location: Saddle Circle 133 Carbondale, CO 81623 Inspection Report Date: 08/18/2023 Test device manufactured by SunRADON, LLC Page 5 of 6 Radon Engineering Consultants 1338 Grand Ave Glenwoo d Springs, CO 81601 970-925-8802 Radon Test Information Radon Risk Information Radon causes lung cancer by means o f the decay of its daughter products after breathing in air contaminated with higher levels of Radon. The World Health Organization (WHO) estimates that 15% of lung cancers worldwide are caused by exposure to elevated indoor levels of Radon. Overall, rado n is the second leading cause of lung cancer responsible f or about 21,000 lung cancer deaths every year in the US alone. Rado n gas is the number one cause o f lung cancer among non-smokers. The U.S. Environmental Pro tection Agency (EPA), the U.S. Surgeon General, and the Center for Disease Co ntrol and Prevention (CDC) strongly recommend that ALL homebuyers have an indoor radon test performed prior to purchase or taking occupancy and reco mmend having the rado n levels professionally mitigated if elevated radon concentrations are found. Understanding Radon Test Results Recommended Action Levels vary by country and typically range from 3 pCi/l (100 Bq/m3) to 8 pCi/l (300 Bq/m3). Recommendatio ns below are based on test results by a Continuous Radon Monito r (CRM) Test of at least 48h duration and are based on recommendations by the EPA. Measured Average Radon Level: At or above 4.0 pCi/l (148 Bq/m3): Corrective measures to reduce exposure to radon gas is strongly recommended (ANSI MAH2014) Between 2-4 pCi/l (74-148 Bq/m3): Consider mitigation or periodic retest as indoor Radon levels vary by season and weather conditions Below 2 pCi/l (74 Bq/m3): Consider bi-annual retest or whenever signif icant changes to the home structure or mechanical systems occurred Test Result: Pass Test Location: Saddle Circle 133 Carbondale, CO 81623 Inspection Report Date: 08/18/2023 Test device manufactured by SunRADON, LLC Page 6 of 6