Loading...
HomeMy WebLinkAboutDesign ReportI DESIGNS ,,BUILT FROM THE GROUND (JPII DESIGN REPORT FOR: 23SS1014 SUNLIGHT MOUNTAIN SKI AREA. SEGUNDO LIFT TERMINAL GLENWOOD SPRINGS, CO August 6,2023 REVIEWED FOR CODE COMPLIANCE SUBIECT TO NOTED EXCEPTTONS & TNSPECTTONS GANFIELI' COUNTY EVO DATE Q4-23 BY NO INSPECTION WIÎHOUÎÎHESE PLANS ON STÎE fpCyr-rg€Î- 6ç ßfc"apU' G leføgyr ËtÎl oÕ:oavr*toÞs oF <ø^) ?*ls€ 5uB¡rnç ¡- tzg?q¿T- Frzôr^ Tltl 6r¡OFrgeÈ âx?u6ùs¿g: LJ ¡atr 'DÍ,¡Þa¡¿ r 8/6/23 191 GeoWall Designs, LLC . (952)303 - 4190 . www.geowalldesigns.com Page 1 Project No.:23SS1014 August 6,2023 lndex 1.0 Site Review 2.0 Design Methodology 3.0 WallSystem 3.2 SoilReinforcement ....3 ....3 3.1 Modular Block Wall Units ............ 4.0 SoilProperties 5.0 Maximum Surcharge Loadings & Slope Conditions 6.0 Hydraulic Conditions 6.1 WaterApplication 6.2 Erosion Control/Prevention..................... 7.0 Seismic Conditions .... 8.0 Wind Conditions ........ 9.0 Extemal Stability and Settlement ... 10.0 Limitations of Report Appendix ltem A: Design References Appendix ltem B: FinalCalculations ... ..3 ..4 ..4 ..4 ..4 ..4 .4 ........4 ........5 ..','.,.6 .3 .3 .3 GeoWall Designs, LLC . (952)303 - 4190 . wutr.geowalldesigns.com Page2 Project No.:23SS1014 August 6,2023 1.0 Site Review This project includes three site retaining walls. Wall 1 is located north of the lower lift terminal with a maximum height of 7.50-feet and horizontal length of 65.50-feet. Wall 2 is located west of the lower lift terminal with a maximum height of 9.00-feetand horizontal length of 118.00-feet. Wall 3 is located south of the upper lifiterminalwith a maximum height of 7.50-feet and horizontal length of 80.50-feet. The walls are located along a slope with primarily cohesive soils and based on the observations of the geotechnical engineer, are placed on an actively moving slope. The retaining walls designed under this submittal are not intended to stabilize the entire hill side and limiting any movement that may occur beyond the limits calculated is outside of this design scope. ln addition, the calculated friction angle from the information within the soils report is less than the graded slopes shown requiring the use of an equivalent surcharge loading for the gravity calculations in lieu of including the back slope when calculating the earth pressure coefficient (Ka). 2.0 Design Methodology The proposed walls have been designed in accordance with the NCMA (National Concrete Masonry Association) design methodology. The walls have been designed using soil reinforcement with portions designed as gravity (without reinforcement). Refer to the NCMA Design Manual for Segmental Retaining Walls, 3rd edition for additional design and construction requirements. 3.0 Wall System 3.1 Modular Block Wall Units The walls have been designed using Redi-Rock 28" and 41" units using the standard 5.2'wall batter. Refer to the manufacturers information for additional details on the proposed retaining wall system and its material properties. 3.2 Soil Reinforcement The proposed design for wall 1 utilizes SF80-PC geogrid soil reinforcement. Refer to the product technical data for the corresponding tensile properties and strength reduction factors. 4.0 Soil Properties Site soils information was obtained from the geotechnical report prepared by Kumar & Associates, lnc. dated 1112312022. The soil strengths shown were back calculated based on information provided within the soils report and shall be verified by the project geotechnical engineer. GeoWall Designs, LLC should be contacted if the noted soil strengths are not met as a redesign may be required. Zone Description 0 c'Y Reinforced Soil 1 Retained Soil 1 Retained Soil2 Foundation Soil 1 Clayey Gravel- GC 28'0 psf 125 pcf Sandy Lean Clay - CL 25'75 psf 125 pcf Gravel- GP 38"0 psf 1 10 pcf Sandy Lean Clay - CL 25"200 psf 125 pcÍ Refer to the referenced soils report for additional information regarding the site soil conditions and geotechnical engineers' recommendations. GeoWall Designs, LLC . (952)303 - 4190 . www.geowalldesigns.com Page 3 Project No.:23SS1014 August 6,2023 5.0 Maximum Surcharge Loadings & Slope Conditions Below are the maximum surcharge and site slope conditions as evaluated within this design. The noted extremes may not be present for the entire length of any given wall. Dead load surcharge loadings are applied in addition to any equivalent geometric loadings applied within the design calculations. Refer to the contract civil plans for locations of all anticipated surcharge locations and grade geometry. WallNo.Live Load (psf) Dead Load (psf) Toe Slope Back Slope 1 2 3 250 N/A 2H:1V 2H:1Y 1q0 N/A Flat 2H:1V 100 N/A Flat 2H:1V 6.0 Hydraulic Conditions 6.'l Water Application The proposed wall(s) are not located within a wetland or water application and the ground water elevation is assumed to be located sufficiently below bottom of wall as to not influence overall stability. The project geotechnical engineer shall consider fluctuations in seasonal ground water elevations during the verification extemal failure mechanisms. 6.2 Erosion Control/Prevention The contractor shall ensure positive drainage is maintained both during and after construction. Erosion prevention and protection shall be maintained above and below the retaining wall as designed by others. All downspouts, swales, and drainage features shall be diverted away from the wall location. 7.0 Seismic Conditions The estimated 1-second peak ground acceleration (S0.,) is than 0.149. Given the relatively low peak ground acceleration and standard reductions in required factors of safety, the static calculations govern the overall design. Seismic calculations have not been included in this design submittal for clarity however, they may be provided upon request. 8.0 Wind Conditions No additional surcharge due to wind is anticipated or included within this design of below grade structures. All freestanding, above grade structures. shall be designed or relocated to not influence the below grade retaining wall within a 1 H:1V zone of influence. Refer to ASCE 7-1 6 for additional information on surcharge applications. 9.0 Extemal Stability and Settlement Global Stability has been evaluated by GeoWall Designs, LLC using soils noted in section 4.0 and shall be verified by the project geotechnical engineer. Local Bearing Capacities and Settlement are not covered under the scope of this design and shall be evaluated under the scope of the project geotechnical engineer. The foundation soils at each wall location shall be capable of supporting the applied bearing capacities shown within the shop drawings without failure or excessive settlement. 10.0 Limitations of Report The design presented within this report is based on the information provided. GeoWall Designs, LLC accepts no liability for verifying site geometry, soil parameters, or ensuring all information provided is up to date. The contractor and/or owne/s representative shall notify GeoWall Designs, LLC of any changes or conflicts with the actual site geometry prior to construction. Verification of site soil conditions, bearing capacities, anticipated settlement, and global stability shall be completed as directed within the construction plans and project specifications. GeoWall Designs, LLC . (952)303 - 4190 . www.geowalldesigns.com Page 4 Project No.:23SS1014 August 6,2023 Appendix ltem A: Design References lron Moutain.Engineering, lnc. plan set for: Segundo Lower Terminal Grading, Project No.: 116.001, Last Dated: 06t14t2023 Kumar & Associates, lnc. report titled: Proposed Segundo Lift Replacement, Project No; 22-7-640, Last Dated: 11t23t2022 NCMA Design Manual for Segmental Retaining Walls, 3rd Edition NCMA SRW Best Practices, 2nd Printing, 2017 ASCE 7-16 Minimum Design Loads and Associated Criteria IBC-2018 lntemational Building Code, 2018 Appendix ltem B: Final Calculations Calculations attached after this sheet NOTE: The calculations on the following pages utilize Mirafi 8XT based on the limitations of the design program. Mirafi 8XT is found to be equivalent to the specified product. The construction drawings provided use SF80-PC which is to be the product installed unless written notification and approval from GeoWall Designs is provided as an altemate. GeoWall Designs, LLC . (952)303 - 4190 . wv\ ^/.geowalldesigns.com Page 5 GtÀ\7i'Tr. '.. = E' ".. I DESIGNS-' ,'-' Project: Sunlight Segundo Lift Job No.: 23SS1014 Date:08/04/23 Section: A-A - Wall 1 8,145 8,140 8.1 35 8,1 30 8 125 8,120 8,1 15 8.1 10 8,1 05 8,1 00 LL = 250 psf 10 <-' 1.355o- RL= 13.0ft LTDS = 4,329 lblft ToCoverage = 25% TopiBottom, 50% Middle 60 70 o (It c) tu 50 Distance n 20 30 40 80 90 100 Unit System: U.S. Customary Units Method: Morgenstern-Price Direction of movement: Left to Right Number of Slices: 30 Minimum Slip Surface Depth: 0.1 ft Entry: (14.1 96074, 8,142\ ft ExÍt (58.956239, 8,119.5219) ft Radius: 29.46794ft Ph¡'(I 28 25 25 Cohesion' (psO 0 2û aÊ Unit Weigtrt (pcr) 145 125 125 125 Name Block Fac¡ng Clayey Gravel - GC Sandy Clay - CL Sandy Clay - CL (F¡ll) Golor T tr T n |IEIIIJIT lE,. REA Analysis Project: Location: Designer: Date: Section: Design Method: Design Unit: 23SS1014 Sunlight Segundo Lift Glenwood Springs, CO BTD 8t6t2023 Wall 1 Section 1 NCMA_09_3rd_Ed, lgnore Vert. Force Redi-Rock PC Èlr: F\ SOIL PARAMETERS 9 Reinforced Soil: 28 deg Retained Soil: 25 deg Foundation Soil: 25 deg Leveling Pad: Crushed Stone Y 125pcf 125pcf 'l25pcf Live Load: Live Load Offset: LL2 Widrh: Dead Load: Dead Load Offset: Dead Load Width: Toe Slope Angle: Toe Slope Length Toe Slope Bench: Pullout: Uncertainties Connection: Bending: coh 0psf 75psf 200psf 13.00 l- GEOMETRY Design Height: 7.50ft (5.00ft Exp.) Wall BatteriTilt: 5.201 0.00 deg Embedment: 2.50ft Leveling Pad Depth: 0.50ft Slope Angle: 26.6 deg Slope Length: 25.0ft Slope Toe Offset: 0.0ft Vertical ı on Single Depth 250psf 0.00ft 100ft 0psf 0.ofr 0ft 26.60 10.00 0.00 FACTORS OF SAFETY Sliding: Overturning: Bearing: Shear: 1.50 2.00 2.O0 1.50 '1.50 1.50 1.50 1.50 10 ïr42 2 1REA Analysi s 5.2.22061.544 1r.7{142.2' *qi LF: l-\ RESULTS FoS Sliding: Bearing Pullout Total Pullout Top FoSot: 2.48 1,299 3.94 29,196 3.84 FoS Overturning: FoS Bearing: FoS Total Pullout FoS Connection: 7.53 12.24 10.32 1.80 r3.[ü l-- umn Descriptions: Ta: allowable geogrid strength Rc %: percent coverage for geosynthetics EP (Pa) internal active earth pressure LL (Pql) earth pressure due to live load surcharge DL (Pqd) earth pressure due to dead load surcharge Tmax maximum earth pressure on geosynthetic layer FSstr factor of safety on geogrid strength (TalTmax) Ta cn allowable tension on the connection FS Pkcn, factor of safety on the connection (Ta cn/Tmax) FS PO, factor of safety on pullout (Ta pullouU(Tmax - LL) Grid Embedment, depth of embedment beyond the theorectical failure plane 2 IL'Herght Length Name la ToCoverage PA LL IMAX l-sstr la(jn FSPKCn FSPo FSSIdg GridEmbedment 4 4.5 50 944 1007 1 951 2.16 2347 1.80138XT2812 1.91419511 9.94 4.98 3 3 13 8XT 28',t2 50 906 403 1 309 3.22 2347 2.69 4.46/113091 7.87 6,87 2 1.5 13 8XT 2812 50 1208 403 161 1 2.62 2347 2.19 5.1 8/f 161 't I 6.29 8.77 2812 1435 40310138XT25 1 4217.73 2347 3520.44 1 1 300.70/[11 5.23 l2.45l 10.bt REA Analysi s 5.2.22061.544 ü{ tt +Êitf¡ f\i 3REA Analysi s 5.2.22061.544 ID Enter Po¡nt X Enter Po¡nt Y Ex¡t Po¡nt X Ex¡t Point Y Center X Genter Y Radius FoS I 29.34 zlJ.92 2.4t 1.50 5.O2 26.60 25.23 1.947 6 29.38 20.o2 2.47 1.50 2.22 30.68 29.14 1.959 E 29.38 20.o2 2.47 1.50 7.11 23.57 22.55 1.980 5 29.38 2(J.o2 2.4t 1.50 -1.85 36.58 35.35 1.997 7 27.88 20.02 2.4t 1.5U 4.41 24.9E 23.60 1.999 5 27.88 20.o2 2.74 4.50 2.04 33.76 29.27 2.041 tt 2t.aa 20.o2 2.4t 1.50 2.O9 24.71 27.22 2.M7 4 29.38 ZU.U2 2.4t 1.b0 -8.43 46.1 5 45.96 2.O50 I 29.38 20.o2 2.47 1.50 8.74 21.20 20.67 2.067 6 29.3E 29.o2 2.61 3.00 3.84 30.63 27.66 2.068 COMPOUND RESULTS Compound stability is a global analysis (Bishop) with the failure planes originating at the top of the slope / wall and exiting out through the face of the wall. For MSE walls, the resistance of the geogrid reinforcement is included in the analysis and the shear resistance of the face units is included. GLOBAL RESULTS Global stability is a global analysis (Bishop) with the failure planes originating at the top of the slope / wall and exiting out below the wall in the area infront of the structure. For MSE walls, the resistance of the geogrid reinforcement is included in the resisting forces. The curve may go through the base of the wall and the wall shear would be included. ln most cases the failure plane will pass below the structure. 4 ID Enter Point X Enter Point Y Exit Po¡nt X Exit Point Y Center X Cente¡ Y Radius FoS 4 29.34 20.o2 -19.2t -2.51 -4.52 33.53 36.50 1.U7 4 29.38 20.02 -8.77 -1.89 -2.77 31.42 34.25 1.311 5 29.38 20.o2 -10.27 -2.51 -2.49 29.96 33.39 1.3tö 6 2t.aa 20.o2 -11.7t -2-51 -2.32 27.O1 31.00 1.379 6 29.38 20.o2 -13.27 -2.51 -3.19 30.05 34.08 1.3t9 6 29_34 20.o2 -11 .77 -2.51 -2.01 28.50 32.51 1.3öU 5 29.38 29.o2 -11.tl -2.51 -3.71 31 .62 35,07 1.385 5 27.88 20.02 -'11.77 -2.51 -3.99 29.96 33.39 1.38ti 5 29.34 20.o2 -13.27 -2.51 -4.94 33.35 36.81 1.392 5 29.38 zlJ.92 -14.n -2.51 -4.38 31 .66 35.71 1,400 REA Ana lysi s 5.2.2206t.544 REA Analysis Project: Location: Designer: Date: Section: Design Method Design Unit: 23SS1014 Sunlight Segundo Lift Glenwood Springs, CO BTD 8t4t2023 Wall 3 Section 1 NCMA_09_3rd_Ed Redi-Rock + \ SOIL PARAMETERS Select Soil: Retained Soil: Foundation Soil: Leveling Pad: GEOMETRY (p 38 deg 25 deg 25 deg 38 deg r.00 63.40 coh 0psf 0psf 20Opsf 0psf Y 1 I Opcf 125pcf 125pcf 1 l0pcf . 342 Design Height: Wall Batter/Tilt: Embedment: Leveling Pad Depth: Slope Angle: Slope Length: Slope Toe Offset: Leveling Pad Width: Vert ı on Single Dpth Select Fill Offset: Select FillAngle: 7.50ft 5.201 0.00 deg 1.00fr 0.50ft 0.0 deg 0.ofr 0.oft 4.42ft Crushed Stone Live Load: Live Load Offset: Live Load Width: Dead Load: Dead Load Offset: Dead Load Width: D.L. Embedment: 1 00psf 0.00ft 100fr 469psf 0.0Ít 100ft 0ft FACTORS OF SAFETY Sliding: Bearing: 1.50 2.00 Overturning 1.50 1REA Ana lysi s 5.2.2206L.544 * \ RESULTS FoS Sliding: Bearing: 1.54 (lvlpd) 1895.83 FoS Overturning FoS Bearing: 1.62 4.00 3.42 Name Elev.[dpth ka Pa Paq Paqd PaT FSsI FoS OT %DIH 28 6.0011 .50 o.210 26 32 148 205 54.10 4.22 15bYo 28 0.183 90 55 257 402 27.60 2.27 78o/o 41 3.0014.50 o.297 330 133 626 1 0E9 12.87 2.41 76Vo 4',l 1.50t6.00 o.275 544 16þ tt3 1482 9.t4 1.91 SlYo 41 u.001/.5u 0.254 787 191 894 1872 f.il 1-62 46% Column Descriptions: ka: active earth pressure coefficient Pa: active earth pressure Paq: live surcharge earth pressure Paq2: live load 2 surcharge earth pressure Paqd: dead surcharge earth pressure (PaC): reduction in load due to cohesion PaT: sum of all earth pressures FSsl(lvl Pad): factor of safety for sliding at each layer FSot: factor of safety of overturning about the toe. (FS sliding below the leveling pad) 2REA Analysi s 5.2.2206L.544