HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 2844 Highway 133, Carbondale, CO 81623
Parcel No.: 246303400012
Owner Name: Antonio Campos and Maria Ruiz Owner Phone: (970) 618‐5036
Designed By: CBO Septic Consulting, Inc. Designer Phone: (970) 309‐5259
Contractor: Antonio Campos and Maria Ruiz Contractor Phone: (970) 618‐5036
Number of Bedrooms _4__Minimum Tank Capacity _1,250‐gal__Minimum Absorption_807.69 SF
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐7688________________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 08/08/2022 Expiration Date 08/08/2023
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by CBO
Septic Consulting, Inc. dated July 11, 2022. Changes must be approved by Garfield County Public
Health and the designer prior to construction.
The new OWTS will serve a new 4‐bedroom residence. The system will consist of a new, two‐
compartment minimum 1,500‐gallon septic tank set level with access to grade and a high‐head
pump in the second compartment of the tank. Effluent will be pressure‐dosed to an Automatic
Distribution Valve (ADV set level with access to grade at the high point of the system that will
distribute effluent to 810 ft2 of STA. The new STA will consist of an over‐excavated 12‐feet wide by
67.5‐feet long unlined sand filter with two zones placed on two feet of secondary sand. The pump
line and laterals shall consist of 1.5‐inch diameter Schedule 40 PVC. Laterals shall have 5/32‐inch
diameter orifices facing down, every three‐feet on‐center (O.C.). Laterals shall end in a sweeping ell
facing up with a ball valve for flushing. Inspection ports are to be installed at each corner of the bed.
Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
08/08/2022
Issued By: Garfield County Environmental Health
Department
Date