HomeMy WebLinkAboutState Rough-In Electrical Inspection ReportCOLORADO STATE ELECTRICAL BOARD
1560 Broadway, Suite 1350
Ðenver, Colorado 80202
Automatic email - Do not repty to this email.
Inspection Report
Permít #: 961586 Date Inspected: 31-AUG-23
PerMit HOldCr: JAMES LARRECHEA
PO BOX 462 RrFLE 81650
Phone : LSJ!1J394222 îaxt
Emait: :lprtelectric0vah99.i ISite: L87 Harmony Lane Carbondale County: Garfield
Owner: Stulgis
Stulgis Resídence Phone ¡ 19701-3!3'4222
Status: ACCEPTED
Inspection Type: Rough In Trim Permit: N
Constuction Type: NEI{ Building Type! RESIÐENTIAL
Inspector: David Sutton 303-869-3458
Coriections: 1) 334.23 fn Accessibte Attics. tlhere run across the top of floor joists' or
within ? ft of the floor or floor joists across the face of rafters or studding' the cable
shall be protected by guard strips that are aÈ least as high as the cable. fnstall protectÍon
of cables in attic sþace. 2¡ 330.6 Listing Requirements. Fittings used for connecting Type MC
cable to boxes, cabinets, or other equipment shall be lísted and identifíed for such use.
Interíor A/C head units do not have listed MC fíttíngs installed.
Comments: Provj-de pictures of corrected MC fitting. OK to cover