HomeMy WebLinkAboutState Rough-In Electrical Inspection ReportCOLORADO STATE ELECTRICAL BOARD 1560 Broadway, Suite 1350 Ðenver, Colorado 80202 Automatic email - Do not repty to this email. Inspection Report Permít #: 961586 Date Inspected: 31-AUG-23 PerMit HOldCr: JAMES LARRECHEA PO BOX 462 RrFLE 81650 Phone : LSJ!1J394222 îaxt Emait: :lprtelectric0vah99.i ISite: L87 Harmony Lane Carbondale County: Garfield Owner: Stulgis Stulgis Resídence Phone ¡ 19701-3!3'4222 Status: ACCEPTED Inspection Type: Rough In Trim Permit: N Constuction Type: NEI{ Building Type! RESIÐENTIAL Inspector: David Sutton 303-869-3458 Coriections: 1) 334.23 fn Accessibte Attics. tlhere run across the top of floor joists' or within ? ft of the floor or floor joists across the face of rafters or studding' the cable shall be protected by guard strips that are aÈ least as high as the cable. fnstall protectÍon of cables in attic sþace. 2¡ 330.6 Listing Requirements. Fittings used for connecting Type MC cable to boxes, cabinets, or other equipment shall be lísted and identifíed for such use. Interíor A/C head units do not have listed MC fíttíngs installed. Comments: Provj-de pictures of corrected MC fitting. OK to cover