Loading...
HomeMy WebLinkAboutEngineer's Letter on Geotech Report Reference€n7ùæe /eúÇ a?1 6e¿þú Keprt Mêmæ- Colleen Wirth From: Sent: lo: Subiect: Attachments: Mike Arbaney < mike@coloradostructural.com > Thursday, August 31, 2023 9:24 AM Colleen Wirth; Bruce Barth Re: BLRE-O8-23-8255 - Nickolay residence Coryell Ranch Lot 29 is now UNDER REVIEW 0983 soilsREPORT.pdf Colleen, The soils report is attached. We had the wrong number on the details sheet. Bruce can update that and resend. Mike Arbaney P.E, Colorado Structural, Inc. tel: (970)-349-5922 fax: (970)-349-5926 mike@coloradostructural. com From : Col leen Wi rth <cwi rth @ ga rfield-cou nty.co m > Date: Thursday, August 3I,2023 at 9:13 AM To: Bruce Barth <bruce@redhousearchitecture.com>, Mike Arbaney <mike@coloradostructural.com> Subject: BLRE-08-23-8255 - Nickolay residence Coryell Ranch Lot 29 is now UNDER REVIEW BLRE-08-23-8255 - Nickolay residence Lot 29 Coryell Ranch, LAO Spirit Mountain Courtesy Message for Nickolay Lot 29 Project Team, Here is the list of corrections or questions to address before issuance of the Nickolay residential project. CORRECTION /o UESTION LIST: 1. Email Kumar & Associates geotechnical report2l,-7-232 as noted by Mike on sheet S3.2. Send to cwirth rfield-co 2. l'm concerned there may be an errata or room label discrepancy on some of architectural sheets and ask for further clarification on some upper floor and attic area details. 3.a Sheet A4.3 Building Section 2 shows an "office", is that correct? (Wondering if that's an errata as an office room has not reflected in the received structural framing pages nor on the electrical plan details). 3.b.Sheet A2.2 Upper Level plan depicts a hot tub deck and bunk room, is that still correct? Please confirm if any room labels have changed. 3.c. Are any spaces on the second story proposed as "unfinished" future living space? 3. We are requesting further information on the proposed unconditioned "attic spaces". 4.a. where are attic access opening(s) proposed to be installed? 1 4.b. willanyof the attic areas be used to house, store oraccess mechanicalequipment, such as 1-2 ERV or whole-house ventilation equipment? lf so, please expound. 4.c. will 220v. evaporative coolers shown on roof plan be "roof mounted" or contained within the "non-vented attic space" 4.d. are any of the attic areas anticipated as "unfinished" future living space? 4.e. will attic access opening(s) be sealed and gasketed pursuant to 2018 IECC to separate from rest of heated, conditioned living space(s)? 4. ln evaluating the plans for compliance with the adopted 2018 IECC (lnternational Energy Conservation Code), there appears to be some missing bits. 4.a. Please have Architect of Record prepare and email a written statement expressing which chosen Energy Compliance Path has been selected forthe Nickolay residence on Lot 29 in Coryell Ranch. Staff comment ond feedbock: lnasmuch os noting U-foctors qnd R-volues on plons submitted with no occompanying RESCheck, RESNET ond HERS RATER doto, moy, indirectly imply one is not pursuing o UA- olterotive nor a Performqnce Method or ERI lndex opproach - we need to know the Architect of Record hos specificolly designed under the PRESCRIPTIVE path ond for us to use PRESCRIPTIVE residential energy volue tobles in the 2078 IECC without any proposed trodeoffs ond without reference to the UA-tables. lf, however, you aim to pursue o performonce poth, we need to know which energy poth ond whot further documents w¡ll be remitted for the file record ond stapled to the issued FIELD COPY for use during construction. 4.b. Provide ManualJ Report 4.c. Provide type and method of the home's proposed Whole-House Ventilation system (exhaust only, supply only, combination supply and exhaust venting system). THANKS FOR YOUR TIME AND CARE ON THIS PROJECT, I LOOK FORWARD TO HEARING A RESPONSE AND SEEING THE NICKOLAY PROJECT MOVE FORWARD. Best regards, Colleen W¡rth Building Plans Examiner Garfield County Community Development 108 8th Street, Suite 401 (970) 94s-1377 ext I6LO cwirth @ ga rfie ld-cou ntv.com 2