Loading...
HomeMy WebLinkAboutGas Fireplace SpecsSLAYTÍIN SERIES 0ptional Accent Media ASPEN GLEN GV 13 CARBONDALE, CO 81623 Driftwood Log Set Glass Media Crushed Glass Reflective Midnight Reflective Copper Tradìtional Log Set Crystals Glacier Amber Rock 4 Driftwood/Rock Black Seabreeze SLAYTÍIN SERIES Specifications Remote Control Burn Videos ASPEN GLEN GV 13 CARBONDALE, CO 81623 Remote control features:TM I(ou¡'ogrl(o¡l:rnor û À tr I llf & Thermostat function Flame height modulation Fan speed modulation Light kit modulation lPl to continuous pilot Split Flow 0ption (Slayton 60 & 42S only) The Komfort Kontrol remote gives you the ability to bring comfort and green technology all together into your home. With the Komfort Kontrol remote, all you have to do is decide a comfortable set point temper¿ture on your remote and when the room temperature gets closer to the point you desire, the Komfort Kontrol remote will turn the flames down accordingly! And with our zone heating, you can save energy and enjoy time in the room you use the most by just turning down the central heat, setting your Komfort Kontrol remote, and enjoy your time around the fireplace with friends, family, or just a good book! That way you'll get to have heat where and when you need it while saving energy and money with just a click of the Komfort Kontrol remote! ffi ffi Slayton 60 Slayton 42S Slayton 36 Outdoor Covered Fireplace lnstall o Fireplaceoperation is approved from 40 degrees Fto 110 degrees F . All wiring connections shall be in accordance with outdoor requirements of NECA NFPA 70 . All clearances and requirements in your appliance manual must be adhered to ROOF OVERHANG BACK OF FIREPI.ACE The overhang (A) must be a minimum of 1/2 or greater of the roofline elevation (B) above the base of the fireplace. The width of the overhang to each side of the appliance (C) must be a m inimum of 1/2 or greater of the roofline elevation (B) above the base of the fireplace. A B EXAMPIE: lf roofline (B) is 10 ft. above the base of the fireplace, the overhang (A) must be 5 ft. or greater. The width of the overhang to EACH side of the fireplace (C) must be 5 ft. or greater. SIDE OF FIRIPLACE FRONT OF FIREPLACE cG SLAYTON 42S Specifications and Clearances (See Vent System Requirements on page 6) Features, 1pti1ns & Spec¡f¡cations arc subiect t0 change. Clearances Refert0 the ¡nstallation manuals for complete installation & venting requirements. See additi0nal mantel clearance c0nfigurations in the installati0n manual. Each unit factory tested Certified to ANSI 221.88 Vented Gas Heaters ASPEN GLEN GV 1 3 CARBONDALE, CO 81623 GAS LINE HOtE s-Ul', TOP Slayton 42S 3/8',55-1/4' LEFT SIDE FRONT 38-5/16' 50' 55-114" CORNER 92-l 19" (483mm)* is the minìmum wall depth required for wall surface materi¿l t0 cover fireplace front. lf fireplace face ìs to be flüsh with the wall surface, subtract 1/2" (13mm) (typical non-combustible finish material) from this dimensi0n. lf other material is to be used, adjust accordingly. o 15-13/16' RIGHT SIDE 5-1tz', IV Recess Construction GAS TINE HOtE 5-t/4', ELECIRICAL ACCESS ffitMil0 stuÐs tusI Mr[Âril f ctrÆact T0vEMrilû 19' 32-9tr6',Height 50'widrh 50'Back Width 15-13/16',0opth 220 lbs.tusight 15-l 1/16" x 42-3l8"Viewing Aroa [G High / low 42,000 / 15,000 LP lligh / Low 42,000 / 15,000 EIIEROUIDE P.4 I{O / tP 72.21% I 75.53v. Steady State ilû / [P 72.98v. / 75.45% AFÛE%ltc/tP 68.0s% t 70.39% Valve Systsm tPt StandardSpllt Flow Burner Enamel (curved)Standard Refractory Requiredûlass Msdia 0ptionalAccent ilodia 0ptionalFan lfit Standardtinhhing Trim lfit RequiredScreoÍ Front Model Slayton 42S 9-15/1 5-3t4",/:\r I 15-1V16" 42-3/8h - 8- 9-11/16' 4"Fmm Applianæ Comen 0"From unit left & right side stand-offs & back 36',Top of fin¡shing edgeto ceiling 6',Side offinishing edge t0 adjacent sidewall Unlt front to combustibles 36', t4-v4" *9" deep prolectionMantel projection from Tireplace finishing edge* Slayton 42SModel 38-3/8', 38-3/8', 1t[', SLAYTÍIN 60 Specifications, Clearances (See Vent System Requirements on page 6) Featurcs, 1pti\ns & Specifications are subiect t0 change. Clearances Refert0 the installation manuals for c0mplete ìnstallation & venting requirements. See additional mantel clearance c0nfigurati0ns in the installation manu¿1. Each unit factory tested Certified to ANSI 221.88 Vented Gas Heaters ASPEN GLEN GV 13 CARBONDALE, CO 81623 Slayton 60 LEFT SIDE 3/8', TOP 7 l-1116', TRONT l5-13/16" 15/16', 77 -7 l8', TV Recess Construction RIGHT SIDE 5-U4', 36-7/8', 3 5-U4', CORNER 1 10-l/8' 4',7r- NÄililGSIUDSTUST M^lilIAtff f ctrñANCt l0vt[tilc 19" (483mm)* is the minimum wall depth required for wall surface material to cover fireplace front. lf f¡replace face is t0 be flush with the wall surface, subtract 1/2" (l3mm) (typical n0n-c0mbustible f¡nish material) from this dimension. lf other material is to be used, adjust accordingly.Fìreplace brochures are for advertising purposes only. Refet t0 the specific lircplace nanual for installation. r 19'.--r{ 31-Vi6"Heíght 66',Ividth 66"Back Widtft l5-13/16"Dêpth Weight 300 lbs. Vievr¡ng Aroa l4-ll4" x 58-3/8" ilo fligh / Low 55,000 / 17,500 LP Í¡gh / Lon 55,000 / 17,500 73.317" I 75.287"ElttRGUtDt P.4 llc / LP 68.6% I 70.5%Steady State ilû / LP 66.44v. I 68.27"/.ATUE%I{G/I.P tPtValve SysÌem StandardSplit Flow Burn8r Enamel (curved)Standard Relractory RequiredGlass Media 0ptionalAccsnt Modia 0ptionalFan Kit StandardFiÍishing Trim lfit RequiredScreen Front Model Slayton 60 5-3/4', 14-U4', 58-3/8', I 8-V8' 4"From Appliance Cornen From unit left & right side stand-offs & back 0' Top ofTinishing edgeto ceiling 36', Side 0ff¡nishing edget0 adjacent sidewall 6' 36',Unit front to combustibles Mantel projection from fireplace finishing edge* r4-1/4" *9" deep projection Slayton 60Model 62-vL', 36-7/8" 11-U8" 36-7l8', l-l/8' ln order to continually provide the highest quality product available, features/options, specifications & dimensions are subject to change. Refer t0 the unit installation manual for complete installation instructi0ns. lnstallati0n must conform with local building c0des. ln some regions it may be p0ssible that this appliance qual¡fies for an energy rebate. See y0ur local deâler f0r details regarding pr0moti0ns and qualificati0ns. F0r complete information 0n the l(ozy Heat product line, please contact us at: F0R CAUF0RiltA RrSr0Er{rs 0iltY A California Proposition 65 lvarning WARillt{û: This product can expose you to chemicals including Carbon Mon0xide, that is an externally vented by-product 0f Tuel combustion, which is [are] known to the State of California to cause birth defects 0r other reprodüctive harm. For more information, visit wwwP6SWarnings.ca gov Manulactured by Hussong Mfg. Co., lnc. 204 lndustrial Park Road, Lakefield, IVlN 56150 Ph0ne1-800-253-4904www.kozyheat.com 10-20 ffi tHl ,fF.¡EIml Product Line: