HomeMy WebLinkAboutPermit Card
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 68 Wilson Lane, Rifle, CO Parcel No.: _217710300021
Owner Name: Lary R and Lori J Schmueser Owner Phone: (970) 948‐5015
Designed By: Huddleston‐Berry Engineering and Testing LLC Designer Phone: (970) 255‐8005
Number of Bedrooms: N/A Minimum Tank Capacity: 500‐gallon Minimum Absorption: 91 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐8325_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _10/23/2023____________________ Expiration Date_10/23/2024_________________
Permit Conditions:
Permit Conditions: This OWTS Permit is approved on the condition of compliance with the design as
submitted by Huddleston‐Berry Engineering and Testing, LLC dated October 4, 2023. Changes must
be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new garage/shop. The system will consist of a new, two‐compartment
minimum 500‐gallon septic tank set level with access to grade and an effluent filter in the outlet tee
of the tank. Effluent will gravity flow to 96 ft2 of STA. The new STA will consist of 1 gravelless trench
with 8 Quick4 chambers. Inspection ports are to be installed at each end of the trench. Maintain all
setbacks and elevations as designed.
Contact Garfield County Public Health at least 48 hours prior to requesting final inspection of the
installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR
APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
10/23/2023
Issued By: Garfield County Environmental Health
Department
Date