Loading...
HomeMy WebLinkAboutOWTS Permit  Garfield County Public Health  2014 Blake Ave.   Glenwood Springs, CO 81601  Phone: (970) 945‐6614 ext. 8150  For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable   Project Address: 80 North Meadow Drive, Rifle, CO  Parcel No.: _217905202002  Owner Name: Shonna and Daniel Scott    Owner Phone: (970) 456‐9741  Designed By: Mountain Cross Engineering, Inc.    Designer Phone: (970) 945‐5544  Number of Bedrooms:  3   Minimum Tank Capacity: 1,000‐gallon  Minimum Absorption: 810 ft2    OWTS PERMIT   KEEP AVAILABLE AT PROJECT SITE   Permit Number _SEPT‐8353_______________________________  Permit Type X New X Repair X Remodel/addition X Tank only   Issue Date _10/24/2023____________________ Expiration Date_10/24/2024_________________   Permit Conditions:   Permit Conditions: This OWTS Permit is approved on the condition of compliance with the design as  submitted by Mountain Cross Engineering, Inc. dated September 28, 2023. Changes must be  approved by Garfield County Public Health and the designer prior to construction.     The new OWTS will replace a failing system and serve an existing 3‐bedroom residence. The system  will consist of a new, three‐compartment minimum 1,000‐gallon septic tank set level with access to  grade with an effluent filter in the outlet tee of the second compartment of the tank and a dosing  siphon in the third compartment of the tank. Effluent will be siphon‐dosed to a distribution box set  level with access to grade that will distribute effluent to 816 ft2 of STA. The new STA will consist of 4  gravelless chamber trenches with each trench consisting of 17 Quick4 chambers, for a total of 68  Quick4 chambers. Inspection ports are to be installed at each end of each trench. Maintain all  setbacks and elevations as designed.   Contact Garfield County Public Health at least 48 hours prior to requesting final inspection of the  installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR  APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.  Agreement   All installations must comply with all requirements of the Garfield County OWTS regulations  including but not limited to the conditions specified above.   In consideration of the issuance of the permit, the applicant hereby agrees to comply with all  laws and regulations related to the zoning, location, construction, and erection of the proposed  OWTS and associated structures for which this permit is granted. The applicant further agrees  that if the above said regulations are not fully complied with in the zoning, location, erection,  and construction of the above described OWTS and structure, the permit may then be revoked  by notice from the Health Department and immediately become null and void.  The issuance of a permit and specifications of terms and conditions therein will not constitute  assumption of liability, nor create presumption that the local public health agency or its  employees may be liable for the failure or malfunctioning of any system. Permit issuance will  not constitute a certification that the system, the equipment used in the system, or any  component used for system operation will ensure continuous compliance with the provision of  the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.   Permit Approval  Plans and specifications for the proposed OWTS have been reviewed and are considered  satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated  in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from  the date of issuance unless construction on the system has commenced. An "as‐built" drawing  must be submitted and inspection of the system must be completed by GCPH before final  approval of the system will be issued.        10/24/2023  Issued By: Garfield County Environmental Health  Department  Date