Loading...
HomeMy WebLinkAboutOWTS Installation Observations 09.12.2023lGrt i;,ffiå'ffi*#ffnn ;-'"5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Ëmploycc Owncd Çompony wwwkumarusa.com Ofrce Locations: Denver (HQ), Parkel Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado September 72,2023 Corey DePaolo 779 East 17ft Street Rifle, Colorado 81650 cdepaolo6T@,$nai1. com Subject: Project No. 19-7-238.02 Certification of Onsite Wastewater Treatment System, Proposed Residence, 961 6Lazy KRoad, Township 65, Range 92W, Section 24 SESW, Garfield County, Colorado Dear Corey: A representative of Kumar & Associates observed the installation of the Onsite Wastewater Treatment System (OV/TS) for the residence at the subject site as required by the Garfield County Environmental Health Departrnent. Our observations and recommendations are presented in this report. The services are supplemental to Kumar & Associates agreemenl for professíonal services to you dated April 16,2019. 'We previously designed the OWTS for the residence as submitted in ourreport dated Jtrne 20, z}lg,ProjectNo. 19-7-238.02. The system was designed for four bedrooms. The OWTS was inst¿lled by you. V/e performed our as-built evaluations on December 23,2021and September 8,2023. The OWTS components observed included: sewer line, cleanouto septic tank, effluent line, effluent pump and soil treatment area (STA), and the locations of these components. The installation and locations of the system components were verified as shown on Figure 1. Pictures of the OWTS components made during the site visit are included with this report. The distance locations to the septíc tank shown on Figure 1 were made by taping. The proposed Valley Precast 1,500-gallon septic tank was changed to a'Westem Gravel 1,500- gallon septic tank. The proposed Orenco effluent pump was changed to a Munro effluent pump. The changes are acceptable to us. On September 8, 2023, after power had been supplied to the pump, a pump performance test was performed with adequate pump pressure observed. It is our opinion that the OWTS was installed in general conformance with the above referenced design. The observations and recommendations presented above are based on our site observations and our experience in the area. We make no warranty either express or implied. Alterations to the system or ímproper backfill and site grading could affectthe operation and effectiveness of the OV/TS. Corey DePaolo September 12,2023 Page2 Please feel &ee to contact us if you have any questions regarding this letter. Respectfully Submitted, Kumar &,4,ssociates, fnc" ffi__ Shane M. Mello, StaffEngineer Reviewedby: David A. Young, P SMM/kac attachments: OWTS Photograph Log Figure I Drawing îH.zj Kumar & Associates. lnc.6 Projec{ No. 19 -7 -238.02 x \ u\ cþ x CRAWLSPACE 4 BEDROOM RESIDENCE CLEANOUT INSTALLED + TOWNSHIP 65, RANGE 92W, SECTION 24 SESW SCALE: 7"=5OO' , 50 O GALLON THREE-CTTAMBER SEPTIC TANK WITH AN EFFLUENT PUMP INSTALLED IN THE TI.TIRD CT:TAMBER. * sorL TREATMENT AREA (SrA) CO]VSISI]VG OF 4 ROWS OF 11 I NFILTRATOR QUI CK4 PLU S STANDARD LOW PROFTLE CÍTAMBERS (44 CTIAMBERS TOTAL)PLACED OJV SAJVD FILTBR. X 25 025 SCALE-FEET 19-7-238,02 Kumar & Associates RECORD DRAWING Fig. 1 OWTS PHOTOGRAPH LOG PROPOSED RESIDENCE TO\ryìtSHrP 65, RANGE 92W, SECTION 24 SESIV 9616LAZY K ROAI) GARFIELD COUNTY, COLORADO k"ÊûRq_"" -'¿-- Photograph 1: 'Westem Gravel 1,500-ga11on septic tank. Sewer line not yet installed. Photograph 2: Effluent line exiting septic tank. w: Project No. l9-7-238.02 O\ryTS PHOTOGRAPH ITOG PROPOSED RESIDENCE TOIV¡ISHIP 65, RANGE 92W, SECTION 24 SESW 9616LAZY K ROAI) GARFIELI)couNTY, coLoRADO Photograph 3: Effluent pump in septic tank. Photograph 4: Soil treatment area (STA) with observation ports. Project No. t9-7-238.02 OWTS PHOIOGRAPIILOG PROFOSED RESIDEF{CE TOlVNSrilp 65, RAITGE Ðyf , SECTTON 24 SESW 9616LAZY I( ROAI) GÂRÍ.TELD COUNTY, COLORÁ.IX) Photograph 5: Control panel and septic tank. Project No. I 9-7-238.02